In Vitro Evaluation of Heat and Moisture Exchangers Designed for Spontaneously Breathing Tracheostomized Patients

被引:7
|
作者
Brusasco, Claudia [1 ]
Corradi, Francesco [3 ]
Vargas, Maria [1 ,6 ]
Bona, Margherita [1 ]
Bruno, Federica [1 ]
Marsili, Maria [1 ]
Simonassi, Francesca [1 ]
Santori, Gregorio [2 ]
Severgnini, Paolo [4 ]
Kacmarek, Robert M. [5 ]
Pelosi, Paolo [1 ]
机构
[1] Univ Genoa, Ist Ricovero & Cura Carattere Sci, Azienda Osped Univ San Martino,Sez Anestesia & Ri, Dipartimento Sci Chirurg & Diagnost Integrate, I-16132 Genoa, Italy
[2] Univ Genoa, Ist Ricovero & Cura Carattere Sci, Azienda Osped Univ San Martino, Dipartimento Sci Chirurg & Diagnost Integrate, I-16132 Genoa, Italy
[3] Azienda Ospedaliero Univ Parma, Sez Terapia Intens Cardiochirurg, Dipartimento Cardionefropolmonare, I-43100 Parma, Italy
[4] Univ Insubria, Dipartimento Sci & Alta Tecnol, Sez Ambiente Salute Sicurezza Terr, Varese, Italy
[5] Massachusetts Gen Hosp, Resp Care Serv, Boston, MA 02114 USA
[6] Univ Naples Federico II, Dipartimento Anestesia & Terapia Intens, Naples, Italy
关键词
tracheostomized patients; absolute humidity; inspiratory air temperature; air conditioning; heat and moisture exchangers; 48 HOURS RATHER; MICROBIOLOGICAL EVALUATION; TEMPERATURE DYNAMICS; TOTAL LARYNGECTOMY; SYSTEM FILTERS; CHANGING HEAT; WATER-VAPOR; HUMIDIFICATION; HUMIDITY; PERFORMANCE;
D O I
10.4187/respcare.02405
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Heat and moisture exchangers (HMEs) are commonly used in chronically tracheostomized spontaneously breathing patients, to condition inhaled air, maintain lower airway function, and minimize the viscosity of secretions. Supplemental oxygen (O-2) can be added to most HMEs designed for spontaneously breathing tracheostomized patients. We tested the efficiency of 7 HMEs designed for spontaneously breathing tracheostomized patients, in a normothermic model, at different minute ventilations ((V) over dot(E)) and supplemental O-2 flows. METHODS: HME efficiency was evaluated using an in vitro lung model at 2 (V) over dot(E) (5 and 15 L/min) and 4 supplemental O-2 flows (0, 3, 6, and 12 L/min). Wet and dry temperatures of the inspiratory flow were measured, and absolute humidity was calculated. In addition, HME efficiency at 0, 12, and 24 h use was evaluated, as well as resistance to flow at 0 and 24 h. RESULTS: The progressive increase in O-2 flow from 0 to 12 L/min was associated with a reduction in temperature and absolute humidity. Under the same conditions, this effect was greater at lower (V) over dot(E). The HME with the best performance provided an absolute humidity of 26 mg H2O/L and a temperature of 27.8 degrees C. No significant changes in efficiency or resistance were detected during the 24 h evaluation. CONCLUSIONS: The efficiency of HMEs in terms of temperature and absolute humidity is significantly affected by O-2 supplementation and (V) over dot(E). (C) 2013 Daedalus Enterprises
引用
收藏
页码:1878 / 1885
页数:8
相关论文
共 50 条
  • [21] Unfavorable mechanical effects of heat and moisture exchangers in ventilated patients
    G. A. Iotti
    M. C. Olivei
    A. Palo
    C. Galbusera
    R. Veronesi
    A. Comelli
    J. X. Brunner
    A. Braschi
    Intensive Care Medicine, 1997, 23 : 399 - 405
  • [22] Mechanical effects of heat-moisture exchangers in ventilated patients
    Iotti, GA
    Olivei, MC
    Braschi, A
    CRITICAL CARE, 1999, 3 (05): : R77 - R82
  • [23] Unfavorable mechanical effects of heat and moisture exchangers in ventilated patients
    Iotti, GA
    Olivei, MC
    Palo, A
    Galbusera, C
    Veronesi, R
    Comelli, A
    Brunner, JX
    Braschi, A
    INTENSIVE CARE MEDICINE, 1997, 23 (04) : 399 - 405
  • [24] The Effects of a "New Generation" of Heat and Moisture Exchangers in Laryngectomized Patients with Previous Heat and Moisture Changer Experience
    Almajali, Omar
    Balk, Matthias
    Rupp, Robin
    Allner, Moritz
    Sievert, Matti
    Iro, Heinrich
    Schuetzenberger, Anne
    Gostian, Antoniu-Oreste
    ENT-EAR NOSE & THROAT JOURNAL, 2023,
  • [25] Can The Dynamic Evaluation Of The Rapid Shallow Breathing Index In Spontaneous Breathing Trial Be A Possible Predictor Of Weaning In Tracheostomized Patients?
    Torres, K. S. C.
    Mota, R. M.
    Dias, M. S.
    Silva, A. P. P.
    Zamora, V. E. C.
    Oliveira, K. C.
    Pereira, M. L. M.
    Toste, E. L.
    Cruz, M. R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [26] Heated humidifiers and heat and moisture exchangers in the treatment of perioperative heat loss and rewarming of hypothermic patients - Heat and moisture exchangers vs active humidifiers in the ventilated lung model
    Rathgeber, J
    Weyland, W
    Bettka, T
    Zuchner, K
    Kettler, D
    ANAESTHESIST, 1996, 45 (09): : 807 - 813
  • [27] Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients
    Boots, RJ
    Howe, S
    George, N
    Harris, FM
    Faoagali, J
    CRITICAL CARE MEDICINE, 1997, 25 (10) : 1707 - 1712
  • [28] EFFECT OF NEBULIZER TYPE AND POSITION ON AEROSOL DRUG DELIVERY DURING SUPPORT MECHANICAL VENTILATION AND SPONTANEOUSLY BREATHING FOR TRACHEOSTOMIZED ADULT PATIENTS
    Kelly, Patrick M.
    O'Sullivan, Andrew
    McKenna, Cathy
    Sweeney, Louise
    MacLoughlin, Ronan
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (04) : A6 - A6
  • [29] Clinical evaluation of a valveless non-absorber breathing system in spontaneously breathing canine patients
    Holden, DJ
    JOURNAL OF SMALL ANIMAL PRACTICE, 2000, 41 (05) : 198 - 201
  • [30] Heat and moisture exchangers and extra tubing impede spontaneous breathing on a ventilator whereas a double lumen tube facilitates it
    Reissmann, H
    Maisch, S
    Fuellekrug, B
    Pothmann, W
    INTENSIVE CARE MEDICINE, 2001, 27 : S212 - S212