In Vitro Evaluation of Heat and Moisture Exchangers Designed for Spontaneously Breathing Tracheostomized Patients

被引:7
|
作者
Brusasco, Claudia [1 ]
Corradi, Francesco [3 ]
Vargas, Maria [1 ,6 ]
Bona, Margherita [1 ]
Bruno, Federica [1 ]
Marsili, Maria [1 ]
Simonassi, Francesca [1 ]
Santori, Gregorio [2 ]
Severgnini, Paolo [4 ]
Kacmarek, Robert M. [5 ]
Pelosi, Paolo [1 ]
机构
[1] Univ Genoa, Ist Ricovero & Cura Carattere Sci, Azienda Osped Univ San Martino,Sez Anestesia & Ri, Dipartimento Sci Chirurg & Diagnost Integrate, I-16132 Genoa, Italy
[2] Univ Genoa, Ist Ricovero & Cura Carattere Sci, Azienda Osped Univ San Martino, Dipartimento Sci Chirurg & Diagnost Integrate, I-16132 Genoa, Italy
[3] Azienda Ospedaliero Univ Parma, Sez Terapia Intens Cardiochirurg, Dipartimento Cardionefropolmonare, I-43100 Parma, Italy
[4] Univ Insubria, Dipartimento Sci & Alta Tecnol, Sez Ambiente Salute Sicurezza Terr, Varese, Italy
[5] Massachusetts Gen Hosp, Resp Care Serv, Boston, MA 02114 USA
[6] Univ Naples Federico II, Dipartimento Anestesia & Terapia Intens, Naples, Italy
关键词
tracheostomized patients; absolute humidity; inspiratory air temperature; air conditioning; heat and moisture exchangers; 48 HOURS RATHER; MICROBIOLOGICAL EVALUATION; TEMPERATURE DYNAMICS; TOTAL LARYNGECTOMY; SYSTEM FILTERS; CHANGING HEAT; WATER-VAPOR; HUMIDIFICATION; HUMIDITY; PERFORMANCE;
D O I
10.4187/respcare.02405
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Heat and moisture exchangers (HMEs) are commonly used in chronically tracheostomized spontaneously breathing patients, to condition inhaled air, maintain lower airway function, and minimize the viscosity of secretions. Supplemental oxygen (O-2) can be added to most HMEs designed for spontaneously breathing tracheostomized patients. We tested the efficiency of 7 HMEs designed for spontaneously breathing tracheostomized patients, in a normothermic model, at different minute ventilations ((V) over dot(E)) and supplemental O-2 flows. METHODS: HME efficiency was evaluated using an in vitro lung model at 2 (V) over dot(E) (5 and 15 L/min) and 4 supplemental O-2 flows (0, 3, 6, and 12 L/min). Wet and dry temperatures of the inspiratory flow were measured, and absolute humidity was calculated. In addition, HME efficiency at 0, 12, and 24 h use was evaluated, as well as resistance to flow at 0 and 24 h. RESULTS: The progressive increase in O-2 flow from 0 to 12 L/min was associated with a reduction in temperature and absolute humidity. Under the same conditions, this effect was greater at lower (V) over dot(E). The HME with the best performance provided an absolute humidity of 26 mg H2O/L and a temperature of 27.8 degrees C. No significant changes in efficiency or resistance were detected during the 24 h evaluation. CONCLUSIONS: The efficiency of HMEs in terms of temperature and absolute humidity is significantly affected by O-2 supplementation and (V) over dot(E). (C) 2013 Daedalus Enterprises
引用
收藏
页码:1878 / 1885
页数:8
相关论文
共 50 条
  • [1] IN VITRO EVALUATION OF SIX DIFFERENT HEAT MOISTURE EXCHANGERS FOR SPONTANEOUSLY BREATHING TRACHEOSTOMIZED PATIENTS
    Brusasco, C.
    Corradi, F.
    Simonassi, F.
    Bona, M.
    Bruno, F.
    Marsili, M.
    Vargas, M.
    Pelosi, P.
    INTENSIVE CARE MEDICINE, 2012, 38 : S68 - S68
  • [2] Preservation of humidity and heat of respiratory gases in spontaneously breathing, tracheostomized patients
    Thomachot, L
    Viviand, X
    Arnaud, S
    Vialet, R
    Albanese, J
    Martin, C
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1998, 42 (07) : 841 - 844
  • [3] HEAT AND MOISTURE EXCHANGERS AND BREATHING FILTERS
    HEDLEY, RM
    ALLTGRAHAM, J
    BRITISH JOURNAL OF ANAESTHESIA, 1994, 73 (02) : 227 - 236
  • [4] Workshop Report: Aerosol Delivery to Spontaneously Breathing Tracheostomized Patients
    Berlinski, Ariel
    Ari, Arzu
    Davies, Phil
    Fink, Jim
    Majaesic, Carina
    Reychler, Gregory
    Tatla, Taran
    Amirav, Israel
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (04) : 207 - 222
  • [5] THE WORK OF BREATHING WITH HEAT AND MOISTURE EXCHANGERS IN THE CIRCLE BREATHING SYSTEM
    OOI, R
    ANAES, FC
    WOOD, M
    ANAES, FC
    ANESTHESIOLOGY, 1993, 79 (3A) : A500 - A500
  • [6] EVALUATION OF HEAT AND MOISTURE EXCHANGERS
    WILKES, AR
    ANAESTHESIA, 1991, 46 (10) : 888 - 888
  • [8] THE WORK OF BREATHING IMPOSED BY HEAT AND MOISTURE EXCHANGERS DURING WEANING
    OOI, R
    BROWNE, G
    SONI, N
    ANESTHESIOLOGY, 1993, 79 (3A) : A295 - A295
  • [9] The respiratory effect of tracheal gas insufflation (TGI) on tracheostomized spontaneously breathing ICU patients
    Grigoriadis, K.
    Tsangaris, I
    Koutsoukou, A.
    Kopterides, P.
    Grammatopoulou, E.
    Grigoriadou, A.
    Armaganidis, A.
    JOURNAL OF CRITICAL CARE, 2018, 48 : 160 - 165
  • [10] AN EVALUATION OF 6 DISPOSABLE HEAT AND MOISTURE EXCHANGERS
    TURTLE, MJ
    ILSLEY, AH
    RUTTEN, AJ
    RUNCIMAN, WB
    ANAESTHESIA AND INTENSIVE CARE, 1987, 15 (03) : 317 - 322