De-bundled single-walled carbon nanotube-modified sensors for simultaneous differential pulse voltammetric determination of ascorbic acid, dopamine, and uric acid

被引:28
|
作者
Thirumalai, Dinakaran [1 ]
Subramani, Devaraju [2 ]
Yoon, Jang-Hee [3 ]
Lee, Jaewon [4 ]
Paik, Hyun-jong [2 ]
Chang, Seung-Cheol [5 ]
机构
[1] Pusan Natl Univ, Grad Dept Chem Mat, Busan 46241, South Korea
[2] Pusan Natl Univ, Dept Polymer Sci & Engn, Busan 46241, South Korea
[3] Korea Basic Sci Inst, Busan Ctr, Busan 46742, South Korea
[4] Pusan Natl Univ, Mol Inflammat Res Ctr Aging Intervent, Coll Pharm, Busan 46241, South Korea
[5] Pusan Natl Univ, Inst Biophysio Sensor Technol, Busan 46241, South Korea
基金
新加坡国家研究基金会;
关键词
TRANSPARENT CONDUCTIVE FILMS; GRAPHENE OXIDE; MODIFIED ELECTRODE; FABRICATION; NANOPARTICLES; NANOMATERIALS; TRYPTOPHAN; DISPERSION; BIOSENSORS; OXIDATION;
D O I
10.1039/c7nj04371f
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new approach based on differential pulse voltammetry (DPV) was developed for the simultaneous determination of ascorbic acid (AA), dopamine (DA), and uric acid (UA) using a modified glassy carbon electrode (GCE). The sensor was constructed by a simple "one-step" technique, wherein de-bundled single-walled carbon nanotubes (SWCNTs) were drop-cast onto the GCE. Without de-bundling, the SWCNTs were poorly dispersed in aqueous solution and were ineffective for the one-step procedure. De-bundling of the SWCNTs was achieved using a small amount (0.1 wt%) of the synthesized polymer dispersant, sulfonated poly(ether sulfone) (SPES); the de-bundled SWCNTs had a high aspect ratio (length = 2.5 +/- 1.0 mu m; height = 2 +/- 1 nm, as determined using transmission electron microscopy and atomic force microscopy). The de-bundled SWCNTs also led to enhanced electrocatalytic activity and selectivity of the modified sensor for the simultaneous determination of AA, DA, and UA in DPV measurements: the peak-to-peak separation values were 221, 119, and 340 mV (vs. Ag/AgCl) for DA-AA, UA-DA, and AA-UA, respectively. The dynamic linear ranges for AA, DA, and UA were 0.2-1.6 mM, 5.0-50 mu M, and 5.0-60 mu M, and the detection limits were 10.6 mu M, 15 nM, and 113 nM (S/N = 3), respectively. The analytical performance of the developed sensor was demonstrated in the determination of AA and DA in commercial pharmaceutical samples (vitamin C tablets and DA injection). The characteristics of the modified sensor make it promising for the individual or simultaneous determination of AA, DA, and UA.
引用
收藏
页码:2432 / 2438
页数:7
相关论文
共 50 条
  • [41] Simultaneous detection of dopamine, ascorbic acid, and uric acid at electrochemically pretreated carbon nanotube biosensors
    Alwarappan, Subbiah
    Liu, Guodong
    Li, Chen-Zhong
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2010, 6 (01) : 52 - 57
  • [42] Carbon nanotube/carbon fiber electrodes via chemical vapor deposition for simultaneous determination of ascorbic acid, dopamine and uric acid
    Zhao, Yankun
    Yang, Zhen
    Fan, Wenxin
    Wang, Yunchao
    Li, Guangzhen
    Cong, Hailin
    Yuan, Hua
    ARABIAN JOURNAL OF CHEMISTRY, 2020, 13 (01) : 3266 - 3275
  • [43] Simultaneous Determination of Dopamine, Ascorbic Acid and Uric Acid at Poly (Crystal Violet) Modified Carbon Paste Electrode
    Shankar, Sharath S.
    Swamy, Bahaddurghatta E. Kumara
    Chandra, Umesh
    Sherigara, Bailure S.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2011, 3 (05): : 462 - 477
  • [44] Simultaneous determination of ascorbic acid, dopamine and uric acid at a nitrogen-doped carbon nanofiber modified electrode
    Sun, Jinying
    Li, Libo
    Zhang, Xueping
    Liu, Dong
    Lv, Simin
    Zhu, Derong
    Wu, Tie
    You, Tianyan
    RSC ADVANCES, 2015, 5 (16) : 11925 - 11932
  • [45] Simultaneous electrochemical determination of ascorbic acid, dopamine and uric acid with helical carbon nanotubes
    Zhang, Bingyan
    Huang, Dekang
    Xu, Xiaobao
    Alemu, Getachew
    Zhang, Yibo
    Zhan, Fang
    Shen, Yan
    Wang, Mingkui
    ELECTROCHIMICA ACTA, 2013, 91 : 261 - 266
  • [46] Electrochemically functionalized carbon cloth for simultaneous determination of ascorbic acid, dopamine, and uric acid
    Ding, Shuang
    Dai, Manxia
    Su, Xinglin
    Guo, Di
    Bian, Lijun
    Liu, Xiaoxia
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 915
  • [47] Simultaneous Voltammetric Determination of Ascorbic Acid, Dopamine and Uric Acid by the Poly(alizarin yellow R)/GCE
    Zhang, Li
    Wang, Hongyan
    Wu, Jian
    Liu, Qiao
    Zhu, Yanyan
    Zhang, Keying
    Zhu, Guang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (08): : 7623 - 7630
  • [48] Graphene-Multiwall Carbon Nanotube-Gold Nanocluster Composites Modified Electrode for the Simultaneous Determination of Ascorbic Acid, Dopamine, and Uric Acid
    Xiaofang Liu
    Shaping Wei
    Shihong Chen
    Dehua Yuan
    Wen Zhang
    Applied Biochemistry and Biotechnology, 2014, 173 : 1717 - 1726
  • [49] CTAB functionalized graphene oxide/multiwalled carbon nanotube composite modified electrode for the simultaneous determination of ascorbic acid, dopamine, uric acid and nitrite
    Yang, Yu Jun
    Li, Weikun
    BIOSENSORS & BIOELECTRONICS, 2014, 56 : 300 - 306
  • [50] Graphene-Multiwall Carbon Nanotube-Gold Nanocluster Composites Modified Electrode for the Simultaneous Determination of Ascorbic Acid, Dopamine, and Uric Acid
    Liu, Xiaofang
    Wei, Shaping
    Chen, Shihong
    Yuan, Dehua
    Zhang, Wen
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2014, 173 (07) : 1717 - 1726