De-bundled single-walled carbon nanotube-modified sensors for simultaneous differential pulse voltammetric determination of ascorbic acid, dopamine, and uric acid

被引:28
|
作者
Thirumalai, Dinakaran [1 ]
Subramani, Devaraju [2 ]
Yoon, Jang-Hee [3 ]
Lee, Jaewon [4 ]
Paik, Hyun-jong [2 ]
Chang, Seung-Cheol [5 ]
机构
[1] Pusan Natl Univ, Grad Dept Chem Mat, Busan 46241, South Korea
[2] Pusan Natl Univ, Dept Polymer Sci & Engn, Busan 46241, South Korea
[3] Korea Basic Sci Inst, Busan Ctr, Busan 46742, South Korea
[4] Pusan Natl Univ, Mol Inflammat Res Ctr Aging Intervent, Coll Pharm, Busan 46241, South Korea
[5] Pusan Natl Univ, Inst Biophysio Sensor Technol, Busan 46241, South Korea
基金
新加坡国家研究基金会;
关键词
TRANSPARENT CONDUCTIVE FILMS; GRAPHENE OXIDE; MODIFIED ELECTRODE; FABRICATION; NANOPARTICLES; NANOMATERIALS; TRYPTOPHAN; DISPERSION; BIOSENSORS; OXIDATION;
D O I
10.1039/c7nj04371f
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new approach based on differential pulse voltammetry (DPV) was developed for the simultaneous determination of ascorbic acid (AA), dopamine (DA), and uric acid (UA) using a modified glassy carbon electrode (GCE). The sensor was constructed by a simple "one-step" technique, wherein de-bundled single-walled carbon nanotubes (SWCNTs) were drop-cast onto the GCE. Without de-bundling, the SWCNTs were poorly dispersed in aqueous solution and were ineffective for the one-step procedure. De-bundling of the SWCNTs was achieved using a small amount (0.1 wt%) of the synthesized polymer dispersant, sulfonated poly(ether sulfone) (SPES); the de-bundled SWCNTs had a high aspect ratio (length = 2.5 +/- 1.0 mu m; height = 2 +/- 1 nm, as determined using transmission electron microscopy and atomic force microscopy). The de-bundled SWCNTs also led to enhanced electrocatalytic activity and selectivity of the modified sensor for the simultaneous determination of AA, DA, and UA in DPV measurements: the peak-to-peak separation values were 221, 119, and 340 mV (vs. Ag/AgCl) for DA-AA, UA-DA, and AA-UA, respectively. The dynamic linear ranges for AA, DA, and UA were 0.2-1.6 mM, 5.0-50 mu M, and 5.0-60 mu M, and the detection limits were 10.6 mu M, 15 nM, and 113 nM (S/N = 3), respectively. The analytical performance of the developed sensor was demonstrated in the determination of AA and DA in commercial pharmaceutical samples (vitamin C tablets and DA injection). The characteristics of the modified sensor make it promising for the individual or simultaneous determination of AA, DA, and UA.
引用
收藏
页码:2432 / 2438
页数:7
相关论文
共 50 条
  • [21] Simultaneous determination of dopamine, ascorbic acid and uric acid with electrospun carbon nanofibers modified electrode
    Liu, Yang
    Huang, Jianshe
    Hou, Haoqing
    You, Tianyan
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (10) : 1431 - 1434
  • [22] Simultaneous Determination of Dopamine, Uric Acid and Ascorbic Acid with CTAB Modified Carbon Paste Electrode
    Shankar, S. Sharath
    Swamy, B. E. Kumara
    Chandra, Umesh
    Manjunatha, J. G.
    Sherigara, B. S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (04): : 592 - 601
  • [23] Simultaneous voltammetric determination of norepinephrine, ascorbic acid and uric acid on polycalconcarboxylic acid modified glassy carbon electrode
    Liu, Ai-Lin
    Zhang, Shao-Bo
    Chen, Wei
    Lin, Xin-Hua
    Xia, Xing-Hua
    BIOSENSORS & BIOELECTRONICS, 2008, 23 (10): : 1488 - 1495
  • [24] Voltammetric determination of folic acid with a multi-walled carbon nanotube-modified gold electrode
    Wei, SH
    Zhao, FQ
    Xu, ZY
    Zeng, BZ
    MICROCHIMICA ACTA, 2006, 152 (3-4) : 285 - 290
  • [25] Carbon-nanotube-modified glassy carbon electrode for simultaneous determination of dopamine, ascorbic acid and uric acid: The effect of functional groups
    Bi, Huaqing
    Li, Yanhui
    Liu, Shufeng
    Guo, Peizhi
    Wei, Zhongbin
    Lv, Chunxiao
    Zhang, Jizhen
    Zhao, X. S.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 1132 - 1140
  • [26] Simultaneous Voltammetric Determination of Norepinephrine, Ascorbic Acid and Uric Acid by TTAB Modified Carbon Paste Electrode
    Shankar, S. Sharath
    Swamy, Bahaddurghatta E. Kumara
    Mahanthesha, Kurangalara R.
    Vishwanatha, Chandrashekar C.
    Kumar, Mohan
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (05): : 555 - 573
  • [27] Simultaneous Voltammetric Determination of Ascorbic Acid, Dopamine and Uric Acid Using Polybromothymol Blue Film-Modified Glassy Carbon Electrode
    Xu, Xiongwei
    Lin, Qihuang
    Liu, Ailin
    Chen, Wei
    Weng, Xiuhua
    Wang, Changlian
    Lin, Xinhua
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2010, 58 (06) : 788 - 793
  • [28] Voltammetric studies of an oracet blue modified glassy carbon electrode and its application for the simultaneous determination of dopamine, ascorbic acid and uric acid
    Zare, HR
    Rajabzadeh, N
    Nasirizadeh, N
    Mazloum-Ardakani, M
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 589 (01) : 60 - 69
  • [29] Polyluminol/Single-Walled Carbon Nanotube Composite Film-Modified Electrodes for Simultaneous Determination of Propyl Gallate and Ascorbic Acid
    Ma, Jing
    Wang, Shuran
    Wang, Maoqing
    Zhang, Jialing
    Wang, Liang
    Du, Xiaoyan
    SENSOR LETTERS, 2010, 8 (04) : 672 - 676
  • [30] Simultaneous determination of ascorbic acid, dopamine and uric acid using a glassy carbon electrode modified with the nickel(II)-bis(1,10-phenanthroline) complex and single-walled carbon nanotubes
    Yan, Songling
    Li, Xi
    Xiong, Yan
    Wang, Mengmeng
    Yang, Linlin
    Liu, Xin
    Li, Xiaoyu
    Alshahrani, Lina Abdullah M.
    Liu, Peng
    Zhang, Chaocan
    MICROCHIMICA ACTA, 2016, 183 (04) : 1401 - 1408