Mitral prosthetic size predictor in minimally invasive mitral valve replacement

被引:5
|
作者
Vo, Anh T. [1 ]
Nguyen, Nguyen T. H. [2 ]
Le, Khoi M. [1 ]
Vuong, Nguyen L. [3 ]
Nguyen, Trang T. T. [1 ]
Vu, Thanh T. [2 ]
Hoang, Sy, V [4 ]
Nguyen, Dinh H. [1 ,2 ]
机构
[1] Univ Med & Pharm Ho Chi Minh City, Univ Med Ctr, Cardiovasc Surg Dept, 215 Hong Bang St,Dist 05, Ho Chi Minh City, Vietnam
[2] Univ Med & Pharm Ho Chi Minh City, Fac Med, Dept Thorac & Cardiovasc Surg, Ho Chi Minh City, Vietnam
[3] Univ Med & Pharm Ho Chi Minh City, Fac Publ Hlth, Dept Med Stat & Informat, Ho Chi Minh City, Vietnam
[4] Univ Med & Pharm Ho Chi Minh City, Fac Med, Dept Internal Med, Ho Chi Minh City, Vietnam
关键词
Prosthetic size predictor; Annular rupture; Minimally invasive approach; Cardiac computed tomography; Transthoracic echocardiography; MISMATCH; SURGERY;
D O I
10.1186/s13019-020-01197-w
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Minimally invasive mitral valve replacement has become popular across the world. However, annular rupture and patient - prosthetic mismatch (PPM) are still problematic, particularly in the Asian population. To avoid this, a predictor model could be beneficial. Our study aimed to assess the value of mitral valve diameters measured on TTE and CT scan on predicting the actual mitral prostheses. Methods From January 2018 to December 2019, a total number of 96 patients underwent minimally invasive mitral valve replacement. The association between imaging measurements and the outcome was checked by scatter plot and Pearson's correlation coefficient. Univariable linear regression was used to build the prediction model. Results The three strongest correlations for the whole population are the following features: Mean TTE diameter (0.702), mean diameter on CT lowest plane through the mitral annulus (0.679), and area-derived diameter on CT highest plane through the mitral annulus (0.665). The prosthetic size of the tissue valve group was more correlated to the calculated annulus diameters than that of the mechanical valve group. Tissue valve size predictor models based on these calculated diameters were 16.19 + 0.27 x d (r = 0.744), 12.74 + 0.44 x d (r = 0.756) and 12.79 + 0.38 x d (r = 0.730), respectively. Conclusion Mitral prosthetic size could be predicted based on the mitral diameters measured on TTE and CT scan. The overall correlation coefficient varied from 0.665 (CT Scan) to 0.702 (TTE). These models performed better when applied to bioprosthesis.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Minimally invasive mitral valve surgery
    Abu-Omar, Yasir
    Fazmin, Ibrahim T.
    Ali, Jason M.
    Pelletier, Marc P.
    JOURNAL OF THORACIC DISEASE, 2021, 13 (03) : 1960 - 1970
  • [32] Minimally invasive Mitral Valve Procedures
    Dunkel, E.
    Zirngast, B.
    Voetsch, A.
    Maechler, H.
    Podesser, B. K.
    Journal fur Kardiologie, 2016, 23 (9-10): : 230 - 233
  • [33] Minimally Invasive Transaortic Mitral Decalcification During Aortic Valve Replacement
    Totsugawa, Toshinori
    Sakaguchi, Taichi
    Hiraoka, Arudo
    Matsushita, Hiroshi
    Hirai, Yuki
    Yoshitaka, Hidenori
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2015, 10 (04) : 288 - 290
  • [34] Minimally invasive mitral valve repair for functional mitral regurgitation
    Girdauskas, Evaldas
    Pausch, Jonas
    Harmel, Eva
    Gross, Tatiana
    Detter, Christian
    Sinning, Christoph
    Kubitz, Jens
    Reichenspurner, Hermann
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 55 : I17 - I25
  • [35] Prosthetic valve thrombosis in a patient with mitral valve replacement
    Bilal, Muhammad
    Khan, Muhammad Shahzeb
    Haseeb, Abdul
    Khan, Abdul Bari
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2015, 65 (07) : 802 - 803
  • [36] TECHNIQUE FOR PROSTHETIC REPLACEMENT OF MITRAL-VALVE
    ELKINS, RC
    GOTT, VL
    BENDER, HW
    BRAWLEY, RK
    SURGERY GYNECOLOGY AND OBSTETRICS WITH INTERNATIONAL ABSTRACTS OF SURGERY, 1972, 134 (03): : 485 - &
  • [37] CARDIOVERSION FOLLOWING PROSTHETIC MITRAL VALVE REPLACEMENT
    SEMER, H
    HULTGREN, H
    KLEIGER, R
    BRANIFF, B
    CIRCULATION, 1967, 35 (03) : 523 - &
  • [38] CARDIOVERSION FOLLOWING PROSTHETIC MITRAL VALVE REPLACEMENT
    SEMER, HA
    KLEIGER, RF
    HULTGREN, HN
    CIRCULATION, 1966, 34 (4S3) : I213 - &
  • [39] PROSTHETIC MITRAL-VALVE REPLACEMENT - REPLY
    FIORE, AC
    ANNALS OF THORACIC SURGERY, 1993, 55 (02): : 562 - 562
  • [40] MIGRATION OF THE PROSTHETIC MITRAL VALVE AFTER TRANSCATHETER MITRAL VALVE REPLACEMENT FOR SEVERE STENOSIS
    Sharma, Saurabh
    Pressman, Gregg
    Witzke, Christian
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 2427 - 2427