Mitral prosthetic size predictor in minimally invasive mitral valve replacement

被引:5
|
作者
Vo, Anh T. [1 ]
Nguyen, Nguyen T. H. [2 ]
Le, Khoi M. [1 ]
Vuong, Nguyen L. [3 ]
Nguyen, Trang T. T. [1 ]
Vu, Thanh T. [2 ]
Hoang, Sy, V [4 ]
Nguyen, Dinh H. [1 ,2 ]
机构
[1] Univ Med & Pharm Ho Chi Minh City, Univ Med Ctr, Cardiovasc Surg Dept, 215 Hong Bang St,Dist 05, Ho Chi Minh City, Vietnam
[2] Univ Med & Pharm Ho Chi Minh City, Fac Med, Dept Thorac & Cardiovasc Surg, Ho Chi Minh City, Vietnam
[3] Univ Med & Pharm Ho Chi Minh City, Fac Publ Hlth, Dept Med Stat & Informat, Ho Chi Minh City, Vietnam
[4] Univ Med & Pharm Ho Chi Minh City, Fac Med, Dept Internal Med, Ho Chi Minh City, Vietnam
关键词
Prosthetic size predictor; Annular rupture; Minimally invasive approach; Cardiac computed tomography; Transthoracic echocardiography; MISMATCH; SURGERY;
D O I
10.1186/s13019-020-01197-w
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Minimally invasive mitral valve replacement has become popular across the world. However, annular rupture and patient - prosthetic mismatch (PPM) are still problematic, particularly in the Asian population. To avoid this, a predictor model could be beneficial. Our study aimed to assess the value of mitral valve diameters measured on TTE and CT scan on predicting the actual mitral prostheses. Methods From January 2018 to December 2019, a total number of 96 patients underwent minimally invasive mitral valve replacement. The association between imaging measurements and the outcome was checked by scatter plot and Pearson's correlation coefficient. Univariable linear regression was used to build the prediction model. Results The three strongest correlations for the whole population are the following features: Mean TTE diameter (0.702), mean diameter on CT lowest plane through the mitral annulus (0.679), and area-derived diameter on CT highest plane through the mitral annulus (0.665). The prosthetic size of the tissue valve group was more correlated to the calculated annulus diameters than that of the mechanical valve group. Tissue valve size predictor models based on these calculated diameters were 16.19 + 0.27 x d (r = 0.744), 12.74 + 0.44 x d (r = 0.756) and 12.79 + 0.38 x d (r = 0.730), respectively. Conclusion Mitral prosthetic size could be predicted based on the mitral diameters measured on TTE and CT scan. The overall correlation coefficient varied from 0.665 (CT Scan) to 0.702 (TTE). These models performed better when applied to bioprosthesis.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Minimally invasive mitral valve operations
    Navia, JL
    Cosgrove, DM
    ANNALS OF THORACIC SURGERY, 1996, 62 (05): : 1542 - 1544
  • [22] Minimally invasive mitral valve surgery
    Walther, T
    Falk, V
    Mohr, FW
    JOURNAL OF CARDIOVASCULAR SURGERY, 2004, 45 (05): : 487 - 495
  • [23] Minimally invasive mitral valve surgery
    Tam, RKW
    Ho, C
    Almeida, AA
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (01): : 246 - 247
  • [24] Minimally invasive mitral valve repair
    Welp, Henryk
    Martens, Sven
    CURRENT OPINION IN ANESTHESIOLOGY, 2014, 27 (01) : 65 - 71
  • [25] Minimally invasive mitral valve surgery
    Moritz, A
    Dogan, S
    Aybek, T
    Kessler, P
    Matheis, G
    Wimmer-Greinecker, G
    ZEITSCHRIFT FUR KARDIOLOGIE, 1999, 88 : 24 - 28
  • [26] Minimally invasive mitral valve repair
    Javadikasgari, Hoda
    Suri, Rakesh M.
    Tappuni, Bassman
    Gillinov, A. Marc
    HEART, 2018, 104 (10) : 861 - 867
  • [27] Minimally invasive mitral valve surgery
    Panwar S.
    Soltesz E.G.
    Current Cardiovascular Risk Reports, 2008, 2 (5) : 359 - 364
  • [28] Minimally invasive mitral valve repair
    Cuartas, Mateo Marin
    Davierwala, Piroze Minoo
    INDIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 36 (Suppl 1) : 44 - 52
  • [29] Minimally invasive mitral valve surgery
    Wilbring M.
    Charitos E.
    Silaschi M.
    Treede H.
    Indian Journal of Thoracic and Cardiovascular Surgery, 2018, 34 (Suppl 2) : 113 - 116
  • [30] Minimally invasive mitral valve surgery
    Sanchez-Espin, Gemma
    Otero, Juan J.
    Rodriguez, Emiliano A.
    Mataro, Maria J.
    Melero, Jose M.
    Porras, Carlos
    Guzon, Arantza
    Such, Miguel
    CIRUGIA CARDIOVASCULAR, 2016, 23 (06): : 276 - 281