In vivo comparison of lumen dimensions measured by time domain-, and frequency domain-optical coherence tomography, and intravascular ultrasound

被引:7
|
作者
Kim, Soo-Joong [1 ,2 ]
Lee, Hang [3 ]
Kato, Koji [1 ]
Yonetsu, Taishi [1 ]
Jang, Ik-Kyung [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Cardiol, Boston, MA 02115 USA
[2] Kyung Hee Univ, Div Cardiol, Coll Med, Seoul, South Korea
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Ctr Biostat, Boston, MA USA
来源
关键词
Time domain; Frequency domain; Optical coherence tomography; Intravascular ultrasound; CORONARY-ARTERIES; ANGIOGRAPHY; VALIDATION; CATHETER; DISEASE; SYSTEM;
D O I
10.1007/s10554-012-0179-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Lumen dimensions measured by time-domain optical coherence tomography (TD-OCT) may be influenced by the hemodynamic effect of proximal balloon occlusion. Frequency-domain OCT (FD-OCT) does not require the interruption of blood flow. Therefore, we compared the coronary lumen dimensions measured by TD-OCT, FD-OCT, and intravascular ultrasound (IVUS) in both stented and non-stented segments. Twenty patients who underwent both IVUS and OCT imaging (10 for TD- and 10 for FD-OCT) after stent implantation were included. The maximum, minimum, and mean diameters and areas were measured at the proximal and distal stent edges, as well as 3 mm inside and 5 mm outside of both edges. The measurements inside stent showed no significant differences between IVUS and TD- or FD-OCT. The lumen mean diameters and areas measured by IVUS at 5 mm outside stent were similar to those measured by FD-OCT (Distal; 3.07 +/- A 0.7 vs 3.03 +/- A 0.7 mm, p = 0.08 and 7.80 +/- A 4.0 vs 7.72 +/- A 4.1 mm(2), p = 0.07, respectively. Proximal; 3.25 +/- A 0.7 vs 3.23 +/- A 0.7 mm, p = 0.09 and 8.78 +/- A 3.8 vs 8.65 +/- A 3.7 mm(2), p = 0.08, respectively), but were greater than those measured by TD-OCT (Distal; 2.75 +/- A 0.5 vs 2.29 +/- A 0.5 mm, p = 0.0001 and 6.15 +/- A 2.6 vs 4.38 +/- A 1.9 mm(2), p = 0.0002, respectively. Proximal; 3.27 +/- A 0.6 vs 2.69 +/- A 0.6 mm, p = 0.0001 and 8.64 +/- A 3.4 vs 6.12 +/- A 2.7 mm(2), p = 0.0001 respectively). The interaction between TD- and FD-OCT for lumen dimension measurements at 5 mm outside stent was statistically significant. Vessel dimension measurements were similar between IVUS and FD-OCT in native vessel unlike with TD-OCT. Therefore, we might adapt the IVUS criteria of lesion severity for percutaneous coronary intervention to FD-OCT.
引用
收藏
页码:967 / 975
页数:9
相关论文
共 50 条
  • [41] A versatile frequency domain multiplexer for optical coherence tomography
    Zurauskas, Mantas
    Podoleanu, Adrian Gh.
    Proceedings of SPIE - The International Society for Optical Engineering, 2013, 8914
  • [42] A versatile frequency domain multiplexer for optical coherence tomography
    Zurauskas, Mantas
    Podoleanu, Adrian Gh.
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: FIBER OPTIC SENSORS AND OPTICAL COHERENCE TOMOGRAPHY, 2013, 8914
  • [43] Frequency domain second harmonic optical coherence tomography
    Su, Jianping
    Tomov, I. V.
    Jiang, Y.
    Chen, Zhongping
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [44] SPECTRAL DOMAIN-OPTICAL COHERENCE TOMOGRAPHY FINDINGS IN ACUTE SYPHILITIC POSTERIOR PLACOID CHORIORETINOPATHY
    Ciardella, Antonio
    Pichi, Francesco
    Cunningham, Emmett
    Jumper, J. Michael
    Davis, Janet
    Albini, Thomas
    Sarraf, David
    Bertelli, Enrico
    Morara, Mariachiara
    Nucci, Paolo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [45] Wide-field spectral domain-optical coherence tomography in central serous chorioretinopathy
    Paola Carrai
    Francesco Pichi
    Francesco Bonsignore
    Antonio P. Ciardella
    Paolo Nucci
    International Ophthalmology, 2015, 35 : 167 - 171
  • [46] Wide-field spectral domain-optical coherence tomography in central serous chorioretinopathy
    Carrai, Paola
    Pichi, Francesco
    Bonsignore, Francesco
    Ciardella, Antonio P.
    Nucci, Paolo
    INTERNATIONAL OPHTHALMOLOGY, 2015, 35 (02) : 167 - 171
  • [47] Comparison of Macular Thickness in Diabetic Macular Edema Using Spectral-Domain Optical Coherence Tomography and Time-Domain Optical Coherence Tomography
    Kakinoki, Masashi
    Miyake, Taichirou
    Sawada, Osamu
    Sawada, Tomoko
    Kawamura, Hajime
    Ohji, Masahito
    JOURNAL OF OPHTHALMOLOGY, 2012, 2012
  • [48] First in man evaluation of intravascular optical frequency domain imaging (OFDI) of Terumo: a comparison with intravascular ultrasound
    Okamura, T.
    Onuma, Y.
    Garcia-Garcia, H. M.
    Van Geuns, R. J. M.
    Wykrzykowska, J. J.
    Schultz, C.
    Van der Giessen, W. J.
    Ligthart, J.
    Regar, E.
    Serruys, P. W.
    EUROPEAN HEART JOURNAL, 2010, 31 : 788 - 788
  • [49] Fourier domain-optical coherence tomography based on a quadrature Mach-Zehnder interferometer
    Fluerara, C.
    Mao, Y.
    Sherif, S.
    Chang, S.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2643 - 2646
  • [50] Evaluation of emulsified silicone oil with spectral domain-optical coherence tomography and fluorescein angiography
    Zafer Cebeci
    Muhammed Talha Sadik
    Mehmet Bedii Ogurel
    Emre Altinkurt
    Nur Kir
    International Ophthalmology, 2020, 40 : 2267 - 2274