In vivo comparison of lumen dimensions measured by time domain-, and frequency domain-optical coherence tomography, and intravascular ultrasound

被引:7
|
作者
Kim, Soo-Joong [1 ,2 ]
Lee, Hang [3 ]
Kato, Koji [1 ]
Yonetsu, Taishi [1 ]
Jang, Ik-Kyung [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Cardiol, Boston, MA 02115 USA
[2] Kyung Hee Univ, Div Cardiol, Coll Med, Seoul, South Korea
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Ctr Biostat, Boston, MA USA
来源
关键词
Time domain; Frequency domain; Optical coherence tomography; Intravascular ultrasound; CORONARY-ARTERIES; ANGIOGRAPHY; VALIDATION; CATHETER; DISEASE; SYSTEM;
D O I
10.1007/s10554-012-0179-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Lumen dimensions measured by time-domain optical coherence tomography (TD-OCT) may be influenced by the hemodynamic effect of proximal balloon occlusion. Frequency-domain OCT (FD-OCT) does not require the interruption of blood flow. Therefore, we compared the coronary lumen dimensions measured by TD-OCT, FD-OCT, and intravascular ultrasound (IVUS) in both stented and non-stented segments. Twenty patients who underwent both IVUS and OCT imaging (10 for TD- and 10 for FD-OCT) after stent implantation were included. The maximum, minimum, and mean diameters and areas were measured at the proximal and distal stent edges, as well as 3 mm inside and 5 mm outside of both edges. The measurements inside stent showed no significant differences between IVUS and TD- or FD-OCT. The lumen mean diameters and areas measured by IVUS at 5 mm outside stent were similar to those measured by FD-OCT (Distal; 3.07 +/- A 0.7 vs 3.03 +/- A 0.7 mm, p = 0.08 and 7.80 +/- A 4.0 vs 7.72 +/- A 4.1 mm(2), p = 0.07, respectively. Proximal; 3.25 +/- A 0.7 vs 3.23 +/- A 0.7 mm, p = 0.09 and 8.78 +/- A 3.8 vs 8.65 +/- A 3.7 mm(2), p = 0.08, respectively), but were greater than those measured by TD-OCT (Distal; 2.75 +/- A 0.5 vs 2.29 +/- A 0.5 mm, p = 0.0001 and 6.15 +/- A 2.6 vs 4.38 +/- A 1.9 mm(2), p = 0.0002, respectively. Proximal; 3.27 +/- A 0.6 vs 2.69 +/- A 0.6 mm, p = 0.0001 and 8.64 +/- A 3.4 vs 6.12 +/- A 2.7 mm(2), p = 0.0001 respectively). The interaction between TD- and FD-OCT for lumen dimension measurements at 5 mm outside stent was statistically significant. Vessel dimension measurements were similar between IVUS and FD-OCT in native vessel unlike with TD-OCT. Therefore, we might adapt the IVUS criteria of lesion severity for percutaneous coronary intervention to FD-OCT.
引用
收藏
页码:967 / 975
页数:9
相关论文
共 50 条
  • [21] Impact of Frequency-Domain Optical Coherence Tomography Guidance for Optimal Coronary Stent Implantation in Comparison With Intravascular Ultrasound Guidance
    Habara, Maoto
    Nasu, Kenya
    Terashima, Mitsuyasu
    Kaneda, Hideaki
    Yokota, Daisuke
    Ko, Euihong
    Ito, Tsuyoshi
    Kurita, Tairo
    Tanaka, Nobuyoshi
    Kimura, Masashi
    Ito, Tatsuya
    Kinoshita, Yoshihisa
    Tsuchikane, Etsuo
    Asakura, Keiko
    Asakura, Yasushi
    Katoh, Osamu
    Suzuki, Takahiko
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (02) : 193 - 201
  • [22] SAFETY AND FEASIBILITY OF FREQUENCY-DOMAIN OPTICAL COHERENCE TOMOGRAPHY ASSESSMENT OF LEFT MAIN CORONARY ARTERY - A COMPARISON WITH INTRAVASCULAR ULTRASOUND
    Fujino, Yusuke
    Costa, Marco A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1444 - E1444
  • [23] Comparison of longitudinal geometric measurement in human coronary arteries between frequency-domain optical coherence tomography and intravascular ultrasound
    Yong Liu
    Kunihiro Shimamura
    Takashi Kubo
    Atsuhi Tanaka
    Hironori Kitabata
    Yasushi Ino
    Takashi Tanimoto
    Yasutsugu Shiono
    Makoto Orii
    Takashi Yamano
    Tomoyuki Yamaguchi
    Kumiko Hirata
    Toshio Imanishi
    Takashi Akasaka
    The International Journal of Cardiovascular Imaging, 2014, 30 : 271 - 277
  • [24] Comparison of Anterior Segment Time Domain Optical Coherence Tomography and High Frequency Ultrasound Biomicroscopy for Anterior Segment
    Cardascia, N.
    Guerriero, S.
    Ferreri, P.
    Furino, C.
    Boscia, F.
    Vetrugno, M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [25] Comparison of central corneal thickness measured by ultrasound pachymetry, corneal topography, spectral domain- optical coherence tomography, and non-contact specular microscopy
    Ulutas, Hafize Gokben
    Ozkaya, Guven
    Hamidi, Nagihan Amuk
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2023, 42
  • [26] Spectral Domain-Optical Coherence Tomography Findings in Unilateral Rubella Retinopathy
    Matalia, Jyoti
    Rajput, Vimal K.
    Shetty, Bhujang K.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (02): : E17 - E18
  • [27] Comparison of retinal nerve fiber layer measured by time domain and spectral domain optical coherence tomography in optic neuritis
    G Rebolleda
    A García-García
    H R Won Kim
    F J Muñoz-Negrete
    Eye, 2011, 25 : 233 - 238
  • [28] Comparison of retinal nerve fiber layer measured by time domain and spectral domain optical coherence tomography in optic neuritis
    Rebolleda, G.
    Garcia-Garcia, A.
    Kim, H. R. Won
    Munoz-Negrete, F. J.
    EYE, 2011, 25 (02) : 233 - 238
  • [29] Analysis of Progression of Reticular Pseudodrusen by Spectral Domain-Optical Coherence Tomography
    Querques, Giuseppe
    Canoui-Poitrine, Florence
    Coscas, Florence
    Massamba, Nathalie
    Querques, Lea
    Mimoun, Gerard
    Bandello, Francesco
    Souied, Eric H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (03) : 1264 - 1270
  • [30] Comparison of iridocorneal angle parameters measured by spectral domain optical coherence tomography and ultrasound biomicroscopy in dogs
    Shim, Jaeho
    Kang, Seonmi
    Jeong, Youngseok
    Lee, Eunji
    Jeong, Dajeong
    Seo, Kangmoon
    VETERINARY OPHTHALMOLOGY, 2022, 25 : 103 - 110