AID - A Novel Method for Improving the Imaging Resolution of a Table-Top Compton Camera

被引:4
|
作者
Seo, Hee [1 ]
Lee, Se Hyung [1 ]
Jeong, Jong Hwi [1 ]
Lee, Ju Hahn [2 ]
Lee, Chun Sik [2 ]
Lee, Jae Sung [3 ,4 ]
Kim, Chan Hyeong [1 ]
机构
[1] Hanyang Univ, Dept Nucl Engn, Seoul 133791, South Korea
[2] Chung Ang Univ, Dept Phys, Seoul 156756, South Korea
[3] Seoul Natl Univ, Dept Nucl Med, Seoul 110744, South Korea
[4] Seoul Natl Univ, Interdisciplinary Program Radiat Appl Life Sci, Seoul 110744, South Korea
关键词
Absorber; Compton camera; Geant4; interaction depth;
D O I
10.1109/TNS.2008.2000777
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A Compton camera is usually composed of a scatterer detector and an absorber detector. The interaction position resolution of the absorber detector is the critical or limiting detector parameter that most seriously affects the imaging resolution of the table-top Compton camera currently under development in our group. Currently, it is assumed that all interactions occur at the centers of the detector segments of the absorber detector (25-segmented germanium detector), which is a simple but obviously not the best practice, considering that the interaction depths of the photons in the absorber detector, especially of low-energy photons, are not distributed uniformly. More photons have interaction in the front region of the detector due to the limited penetrating depth of the photons. Therefore, the present study developed a novel, "average interaction depth (AID)" method, which improves the imaging resolution of Compton camera by additionally considering the average interaction depth of the incident photon in the absorber detector. Simulations with Geant4 showed that the imaging resolution of the Compton camera can be significantly improved by using the AID method. For example, the resolution for a 511 keV gamma point source was improved from 9.9 mm to 7.6 mm in full width half maximum (FWRM). For a 364 keV gamma point source, the improvement was even more significant from 11.4 mm to 7.2 mm.
引用
收藏
页码:2527 / 2530
页数:4
相关论文
共 50 条
  • [31] Visualizing the ultra-structure of microorganisms using table-top extreme ultraviolet imaging
    Chang Liu
    Wilhelm Eschen
    Lars Loetgering
    Daniel S. Penagos Molina
    Robert Klas
    Alexander Iliou
    Michael Steinert
    Sebastian Herkersdorf
    Alexander Kirsche
    Thomas Pertsch
    Falk Hillmann
    Jens Limpert
    Jan Rothhardt
    PhotoniX, 4
  • [32] Towards a table-top microscope for nanoscale magnetic imaging using picosecond thermal gradients
    J. M. Bartell
    D. H. Ngai
    Z. Leng
    G. D. Fuchs
    Nature Communications, 6
  • [33] First application of the super -resolution imaging technique using a Compton camera
    Sato, S.
    Kataoka, J.
    Kotoku, J.
    Taki, M.
    Oyama, A.
    Tagawa, L.
    Fujieda, K.
    Nishi, F.
    Toyoda, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 969
  • [34] Single-shot table-top coherent x-ray imaging with diffraction-limited resolution by nonlinear phase variations
    Lee, Kyoung Hwan
    Yun, Hyeok
    Sung, Jae Hee
    Lee, Seong Ku
    Lee, Hwang Woon
    Kim, Hyung Taek
    Depresseux, A.
    Gautier, J.
    Tissandier, F.
    Goddet, J-P
    Sebban, S.
    Nam, Chang Hee
    JOURNAL OF OPTICS, 2020, 22 (08)
  • [35] Lensless Imaging Using Table-Top Soft X-Ray Lasers and High Harmonics Sources Reaching 70 nm Resolution
    Sandberg, R. L.
    Wachulak, P. W.
    Raymondson, D. A.
    Paul, A.
    Sakdinawat, A. E.
    Amirbekian, B.
    Lee, E.
    Liu, Y.
    La-O-Vorakiat, C.
    Song, C.
    Marconi, M. C.
    Menoni, C. S.
    Murnane, M. M.
    Rocca, J. J.
    Kapteyn, H. C.
    Miao, J.
    X-RAY LASERS 2008, PROCEEDINGS, 2009, 130 : 433 - 437
  • [36] Measurement of “Shock Wave Parameters” in a Novel Table-Top Shock Tube Using Microphones
    Sivakumar A.
    Balachandar S.
    Dhas S.A.M.B.
    Human Factors and Mechanical Engineering for Defense and Safety, 2020, 4 (1):
  • [37] Comparison of 50° handheld fundus camera versus ultra-widefield table-top fundus camera for diabetic retinopathy detection and grading
    Midena, Edoardo
    Zennaro, Luca
    Lapo, Cristian
    Torresin, Tommaso
    Midena, Giulia
    Frizziero, Luisa
    EYE, 2023, 37 (14) : 2994 - 2999
  • [38] Comparison of 50° handheld fundus camera versus ultra-widefield table-top fundus camera for diabetic retinopathy detection and grading
    Edoardo Midena
    Luca Zennaro
    Cristian Lapo
    Tommaso Torresin
    Giulia Midena
    Luisa Frizziero
    Eye, 2023, 37 : 2994 - 2999
  • [39] High-speed and high-resolution table-top coherent diffractive imaging towards ptychography and 3D tomography
    Tadesse, G. K.
    Klas, R.
    Demmler, S.
    Haedrich, S.
    Wahyutama, I.
    Zurich, M.
    Steinert, M.
    Spielmann, C.
    Pertsch, T.
    Tunnermann, A.
    Limpert, J.
    Rothhardt, J.
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC), 2017,
  • [40] Nanoscale imaging with table-top coherent extreme ultraviolet source based on high harmonic generation
    Khuong Ba Dinh
    Hoang Vu Le
    Hannaford, Peter
    Lap Van Dao
    OPTICS COMMUNICATIONS, 2017, 396 : 100 - 104