AID - A Novel Method for Improving the Imaging Resolution of a Table-Top Compton Camera

被引:4
|
作者
Seo, Hee [1 ]
Lee, Se Hyung [1 ]
Jeong, Jong Hwi [1 ]
Lee, Ju Hahn [2 ]
Lee, Chun Sik [2 ]
Lee, Jae Sung [3 ,4 ]
Kim, Chan Hyeong [1 ]
机构
[1] Hanyang Univ, Dept Nucl Engn, Seoul 133791, South Korea
[2] Chung Ang Univ, Dept Phys, Seoul 156756, South Korea
[3] Seoul Natl Univ, Dept Nucl Med, Seoul 110744, South Korea
[4] Seoul Natl Univ, Interdisciplinary Program Radiat Appl Life Sci, Seoul 110744, South Korea
关键词
Absorber; Compton camera; Geant4; interaction depth;
D O I
10.1109/TNS.2008.2000777
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A Compton camera is usually composed of a scatterer detector and an absorber detector. The interaction position resolution of the absorber detector is the critical or limiting detector parameter that most seriously affects the imaging resolution of the table-top Compton camera currently under development in our group. Currently, it is assumed that all interactions occur at the centers of the detector segments of the absorber detector (25-segmented germanium detector), which is a simple but obviously not the best practice, considering that the interaction depths of the photons in the absorber detector, especially of low-energy photons, are not distributed uniformly. More photons have interaction in the front region of the detector due to the limited penetrating depth of the photons. Therefore, the present study developed a novel, "average interaction depth (AID)" method, which improves the imaging resolution of Compton camera by additionally considering the average interaction depth of the incident photon in the absorber detector. Simulations with Geant4 showed that the imaging resolution of the Compton camera can be significantly improved by using the AID method. For example, the resolution for a 511 keV gamma point source was improved from 9.9 mm to 7.6 mm in full width half maximum (FWRM). For a 364 keV gamma point source, the improvement was even more significant from 11.4 mm to 7.2 mm.
引用
收藏
页码:2527 / 2530
页数:4
相关论文
共 50 条
  • [21] Material-specific high-resolution table-top extreme ultraviolet microscopy
    Wilhelm Eschen
    Lars Loetgering
    Vittoria Schuster
    Robert Klas
    Alexander Kirsche
    Lutz Berthold
    Michael Steinert
    Thomas Pertsch
    Herbert Gross
    Michael Krause
    Jens Limpert
    Jan Rothhardt
    Light: Science & Applications, 11
  • [22] Study on the Imaging Resolution of a Multiply-stacked Compton Camera
    Kim, N. Y.
    Lee, J. H.
    Lee, C. S.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 55 (04) : 1409 - 1415
  • [23] Analysis and simultion. for Compton camera's imaging resolution
    Song Zhang-Yong
    Yu De-Yang
    Cai Xiao-Hong
    ACTA PHYSICA SINICA, 2019, 68 (11)
  • [24] Material-specific high-resolution table-top extreme ultraviolet microscopy
    Eschen, Wilhelm
    Loetgering, Lars
    Schuster, Vittoria
    Klas, Robert
    Kirsche, Alexander
    Berthold, Lutz
    Steinert, Michael
    Pertsch, Thomas
    Gross, Herbert
    Krause, Michael
    Limpert, Jens
    Rothhardt, Jan
    LIGHT-SCIENCE & APPLICATIONS, 2022, 11 (01)
  • [25] A novel multi-radionuclide imaging method based on mechanical collimated Compton camera
    Wu, Renyao
    Geng, Changran
    Tian, Feng
    Li, Mingzhu
    Xu, Jianfeng
    Cai, Fei
    Tang, Xiaobin
    RADIATION MEASUREMENTS, 2023, 164
  • [26] Towards a table-top microscope for nanoscale magnetic imaging using picosecond thermal gradients
    Bartell, J. M.
    Ngai, D. H.
    Leng, Z.
    Fuchs, G. D.
    NATURE COMMUNICATIONS, 2015, 6
  • [27] The Improving of the Angular Resolution of Gamma-Ray Images of Portable Compton Camera with Special Iterational Method
    Ivanov, O. P.
    Potapov, V. N.
    Safronov, A. M.
    Stepanov, A. V.
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [28] TABLE-TOP SUPPORT PLATE FOR IMAGING THE ENTIRE SPINE WITH SURFACE-COIL MR
    KROL, G
    SZE, G
    AMSTER, J
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (02) : 396 - 397
  • [29] Handheld Fundus Camera for Diabetic Retinopathy Screening: A Comparison Study with Table-Top Fundus Camera in Real-Life Setting
    Midena, Edoardo
    Zennaro, Luca
    Lapo, Cristian
    Torresin, Tommaso
    Midena, Giulia
    Pilotto, Elisabetta
    Frizziero, Luisa
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (09)
  • [30] Visualizing the ultra-structure of microorganisms using table-top extreme ultraviolet imaging
    Liu, Chang
    Eschen, Wilhelm
    Loetgering, Lars
    Molina, Daniel Penagos S.
    Klas, Robert
    Iliou, Alexander
    Steinert, Michael
    Herkersdorf, Sebastian
    Kirsche, Alexander
    Pertsch, Thomas
    Hillmann, Falk
    Limpert, Jens
    Rothhardt, Jan
    PHOTONIX, 2023, 4 (01)