Photon attenuation parameters for some tissues from Geant4 simulation, theoretical calculations and experimental data: a comparative study

被引:15
|
作者
Arslan, Halil [1 ]
机构
[1] Sakarya Univ Appl Sci, Elect & Elect Engn, Sakarya, Turkey
关键词
Attenuation coefficient; Effective atomic number; Geant4; simulation; Tissue model; EFFECTIVE ATOMIC NUMBERS; ENERGY-ABSORPTION COEFFICIENTS; MASS ATTENUATION; DOSIMETRIC MATERIALS; ELECTRON-DENSITIES; SHIELDING PROPERTIES; NANO-PARTICLES; XCOM PROGRAM; SUBSTITUTES; EQUIVALENT;
D O I
10.1007/s41365-019-0617-z
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Mass attenuation coefficients, effective atomic numbers, effective electron densities and Kerma relative to air for adipose, muscle and bone tissues have been investigated in the photon energy region from 20 keV up to 50 MeV with Geant4 simulation package and theoretical calculations. Based on Geant4 results of the mass attenuation coefficients, the effective atomic numbers for the tissue models have been calculated. The calculation results have been compared with the values of the Auto-Zeff program and with other studies available in the literature. Moreover, Kerma of studied tissues relative to air has been determined and found to be dependent on the absorption edges of the tissue constituent elements.
引用
收藏
页数:10
相关论文
共 47 条
  • [1] Photon attenuation parameters for some tissues from Geant4 simulation, theoretical calculations and experimental data: a comparative study
    Halil Arslan
    Nuclear Science and Techniques, 2019, 30
  • [2] Photon attenuation parameters for some tissues from Geant4simulation, theoretical calculations and experimental data:a comparative study
    Halil Arslan
    Nuclear Science and Techniques, 2019, 30 (06) : 59 - 68
  • [3] Mass attenuation coefficients of composite materials by Geant4, XCOM and experimental data: comparative study
    Medhat, M. E.
    Singh, V. P.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2014, 169 (09): : 800 - 807
  • [4] Mass attenuation coefficients, water and tissue equivalence properties of some tissues by Geant4, XCOM and experimental data
    Al-Buriahi, Mohammed Sultan
    Arslan, Halil
    Tonguc, Bans T.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2019, 57 (06) : 433 - 437
  • [5] Photon attenuation coefficients of oxide dispersion strengthened steels by Geant4, XCOM and experimental data
    Li, Jingtai
    Huang, Mei
    Hou, Rongbin
    Ouyang, Xiaoping
    RADIATION PHYSICS AND CHEMISTRY, 2019, 161 : 23 - 28
  • [6] Photon attenuation coefficients of thermoluminescent dosimetric materials by Geant4 toolkit, XCOM program and experimental data: A comparison study
    Singh, Vishwanath P.
    Medhat, M. E.
    Badiger, N. M.
    ANNALS OF NUCLEAR ENERGY, 2014, 68 : 96 - 100
  • [7] Photon attenuation coefficients of different rock samples using MCNPX, Geant4 simulation codes and experimental results: a comparison study
    Obaid, Shamsan S.
    Sayyed, M. I.
    Gaikwad, D. K.
    Tekin, H. O.
    Elmahroug, Y.
    Pawar, P. P.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2018, 173 (11-12): : 900 - 914
  • [8] Photon attenuations of trichloride of gadolinium by Geant4 and XCom: a comparative study
    Saim, A.
    Belkharroubi, F.
    Maroc, F. Z.
    Blaha, L. F.
    Ameri, I.
    Ameri, M.
    Tebboune, A.
    Belkaid, M. N.
    Al-Douri, Y.
    JOURNAL OF TAIBAH UNIVERSITY FOR SCIENCE, 2023, 17 (01):
  • [9] Photon and electron attenuation parameters of phosphate and borate bioactive glasses by using Geant4 simulations
    Boukhris, Imed
    Kebaili, Imen
    Al-Buriahi, M. S.
    Alalawi, Amani
    Abouhaswa, A. S.
    Tonguc, Baris
    CERAMICS INTERNATIONAL, 2020, 46 (15) : 24435 - 24442
  • [10] Experimental and Geant4 Simulation Study of MURA Mask for Scintimammography
    Alnafea, Mohammed A.
    Shamma, Khaled
    Kadri, Omrane
    APPLIED SCIENCES-BASEL, 2022, 12 (10):