Photon attenuations of trichloride of gadolinium by Geant4 and XCom: a comparative study

被引:0
|
作者
Saim, A. [1 ]
Belkharroubi, F. [1 ,2 ]
Maroc, F. Z. [1 ]
Blaha, L. F. [2 ]
Ameri, I. [2 ]
Ameri, M. [2 ]
Tebboune, A. [1 ]
Belkaid, M. N. [1 ]
Al-Douri, Y. [3 ,4 ,5 ,6 ,7 ,8 ,9 ]
机构
[1] Univ Sci & Technol Oran Mohamed Boudiaf USTO MB, Fac Phys, Dept Engn Phys, Lab Anal & Applicat Radiat LAAR, Oran, Algeria
[2] Univ DjillaliLiabes, Lab Phys Chem Adv Mat LPCMA, Sidi Bel Abbes, Algeria
[3] Univ Malaya, Nanotechnol & Catalysis Res Ctr NANOCAT, Kuala Lumpur, Malaysia
[4] Bahcesehir Univ, Fac Engn & Nat Sci, Dept Mechatron Engn, Istanbul, Turkiye
[5] Univ Sharjah, Coll Sci, Dept Appl Sci & Astron, Sharjah, U Arab Emirates
[6] Univ Malaya, Nanotechnol & Catalysis Res Ctr NANOCAT, Kuala Lumpur 50603, Malaysia
[7] Bahcesehir Univ, Fac Engn & Nat Sci, Dept Mechatron Engn, TR-34349 Istanbul, Turkiye
[8] Univ Sharjah, Coll Sci, Dept Appl Sci & Astron, POB 27272, Sharjah, U Arab Emirates
[9] Piri Reis Univ, Fac Engn, Dept Mech Engn, Eflatun Sk 8, TR-34940 Istanbul, Turkiye
来源
关键词
GdCl3; XRD; WinXCom; Geant4; COEFFICIENTS;
D O I
10.1080/16583655.2023.2168335
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The total mass attenuation coefficient of trichloride gadolinium has been investigated utilizing Geant4 compared with WinXCom simulation data at energies; 1-10 MeV. The simulated results are used to calculate the total cross section, atomic and electronic cross sections. The aim of this work is to characterize new materials and their interactions with radiation in order to be able for using in shielding or detection. The GdCl3 is applied for super-Kamiokande detector of neutrons. From our comparison study, it is found that the mass attenuation coefficient of GdCl3 with those of two detectors of X-ray (Si and CdTe) is very closed. Also, the total mass transfer attenuation coefficient increases as high energies increases at pairs effect production. From our comparison study, we can predict that GdCl3 can be a good detector of X-ray and concluded that this material has shown good interaction with electromagnetic radiations at high energies.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Mass attenuation coefficients of composite materials by Geant4, XCOM and experimental data: comparative study
    Medhat, M. E.
    Singh, V. P.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2014, 169 (09): : 800 - 807
  • [2] Photon attenuation coefficients of oxide dispersion strengthened steels by Geant4, XCOM and experimental data
    Li, Jingtai
    Huang, Mei
    Hou, Rongbin
    Ouyang, Xiaoping
    RADIATION PHYSICS AND CHEMISTRY, 2019, 161 : 23 - 28
  • [3] Photon attenuation coefficients of thermoluminescent dosimetric materials by Geant4 toolkit, XCOM program and experimental data: A comparison study
    Singh, Vishwanath P.
    Medhat, M. E.
    Badiger, N. M.
    ANNALS OF NUCLEAR ENERGY, 2014, 68 : 96 - 100
  • [4] Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental data
    Medhat, M. E.
    Singh, V. P.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2016, 54 (02) : 137 - 143
  • [5] Implementation of photon elastic scattering in GEANT4
    Turturica, G. V.
    Iancu, V.
    Suliman, G.
    Ur, C. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2018, 436 : 68 - 73
  • [6] Shielding properties of Cu-Sn-Pb alloy by Geant4, XCOM and experimental data
    Taqi, Ali H.
    Ghalib, Abdulahdi M.
    Mohammed, Hilala N.
    MATERIALS TODAY COMMUNICATIONS, 2021, 26 (26):
  • [7] Photon Elastic Scattering Simulation: Validation and Improvements to Geant4
    Batic, Matej
    Hoff, Gabriela
    Pia, Maria Grazia
    Saracco, Paolo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (04) : 1636 - 1664
  • [8] Photon attenuation parameters for some tissues from Geant4 simulation, theoretical calculations and experimental data: a comparative study
    Arslan, Halil
    NUCLEAR SCIENCE AND TECHNIQUES, 2019, 30 (06)
  • [9] OPSimTool: A custom tool for optical photon simulation in Geant4
    Kandemir, Mustafa
    COMPUTER PHYSICS COMMUNICATIONS, 2023, 292
  • [10] Accuracy of the photon and electron physics in GEANT4 for radiotherapy applications
    Poon, E
    Verhaegen, F
    MEDICAL PHYSICS, 2005, 32 (06) : 1696 - 1711