摘要
Mass attenuation coefficients, effective atomic numbers, effective electron densities and Kerma relative to air for adipose, muscle and bone tissues have been investigated in the photon energy region from 20 keV up to 50 MeV with Geant4 simulation package and theoretical calculations. Based on Geant4 results of the mass attenuation coefficients, the effective atomic numbers for the tissue models have been calculated. The calculation results have been compared with the values of the Auto-Zeff program and with other studies available in the literature. Moreover, Kerma of studied tissues relative to air has been determined and found to be dependent on the absorption edges of the tissue constituent elements.
引用
收藏
页数:10
相关论文
共 47 条
  • [31] Comparative Study Between Geant4, MCNP6 and Experimental Results Against Gamma Radiation Comes from a Cobalt-60 Source
    El-Ouardi, Y.
    Dadouch, A.
    Aknouch, A.
    Mouhib, M.
    Maghnouj, A.
    Didi, A.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2020, 75 (05) : 507 - 511
  • [32] Experimental measurements and GEANT4 simulations for a comparative study of efficiencies of LaBr3:Ce, NaI(Tl), and BaF2
    Kumar, G. Anil
    Mazumdar, I.
    Gothe, D. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (02): : 522 - 529
  • [33] Comparison between MCNP5, Geant4 and experimental data for gamma rays attenuation of PbO-BaO-B2O3 glasses
    Almatari, M.
    Issa, Shams A. M.
    Dong, M. G.
    Sayyed, M. I.
    Ayad, R.
    HELIYON, 2019, 5 (08)
  • [34] Emission of Secondary Particles From a PMMA Phantom During Proton Irradiation: A Simulation Study with the Geant4 Monte Carlo Toolkit
    Lau, A.
    Chen, Y.
    Ahmad, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 346 - 346
  • [35] A Simulation Study with Geant4 Investigating the Secondary Prompt Gamma Emissions From Incident 40 MeV Protons Onto Various Materials
    Lau, A.
    Chen, Y.
    Ahmad, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3773 - 3773
  • [36] Validation of GEANT4 simulations for percentage depth dose calculations in heterogeneous media by using small photon beams from the 6-MV Cyberknife: Comparison with photon beam dosimetry with EBT2 film
    Lee, Chung Il
    Yoon, Sei-Chul
    Shin, Jae Won
    Hong, Seung-Woo
    Suh, Tae Suk
    Min, Kyung Joo
    Lee, Sang Deok
    Chung, Su Mi
    Jung, Jae-Yong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (08) : 1308 - 1316
  • [37] Validation of GEANT4 simulations for percentage depth dose calculations in heterogeneous media by using small photon beams from the 6-MV Cyberknife: Comparison with photon beam dosimetry with EBT2 film
    Chung Il Lee
    Sei-Chul Yoon
    Jae Won Shin
    Seung-Woo Hong
    Tae Suk Suh
    Kyung Joo Min
    Sang Deok Lee
    Su Mi Chung
    Jae-Yong Jung
    Journal of the Korean Physical Society, 2015, 66 : 1308 - 1316
  • [38] Eco-friendly gamma radiation protection using waste rice straw and animal glue enhanced by micro and nano iron oxide: a Geant4 simulation and experimental study
    El-Khatib, Ahmed M.
    Alabsy, Mahmoud T.
    Sharaby, Mahmoud A.
    Abd Elzaher, Mohamed
    Doma, A. S.
    Abbas, Mahmoud, I
    PHYSICA SCRIPTA, 2025, 100 (02)
  • [39] GEANT4 PARAMETRIZATION AND MODELING OF PION PRODUCTION IN PROTON-NUCLEUS INTERACTIONS BASED ON HARP EXPERIMENTAL DATA: INCIDENT PROTON MOMENTA ARE FROM 3 GEV/C TO 12.9 GEV/C
    Giani, Simone
    Ivanchenko, Vladimir
    Panman, Jaap
    Grichine, Vladimir
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 786 - +
  • [40] Organ doses from hepatic radioembolization with 90Y, 153Sm, 166Ho and 177Lu: A Monte Carlo simulation study using Geant4
    Hashikin, N. A. A.
    Yeong, C. H.
    Guatelli, S.
    Abdullah, B. J. J.
    Ng, K. H.
    Malaroda, A.
    Rosenfeld, A. B.
    Perkins, A. C.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694