Variable Lung Density Consideration in Attenuation Correction of Whole-Body PET/MRI

被引:38
|
作者
Marshall, Harry R. [1 ,2 ]
Prato, Frank S. [3 ]
Deans, Lela
Theberge, Jean [3 ]
Thompson, R. Terry [3 ]
Stodilka, Robert Z. [4 ]
机构
[1] Lawson Hlth Res Inst, Dept Imaging, Imaging Program, London, ON N6A 4V2, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] St Josephs Hlth Ctr, Dept Diagnost Imaging, London, ON, Canada
[4] London Hlth Sci Ctr, London, ON, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
PET/MRI; attenuation correction; lung density; segmentation; whole-body imaging; PET; SEGMENTATION; QUANTITATION; PERFUSION; SYSTEMS; TISSUE;
D O I
10.2967/jnumed.111.098350
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Present attenuation-correction algorithms in whole-body PET/MRI do not consider variations in lung density, either within or between patients; this may adversely affect accurate quantification. In this work, a technique to incorporate patient-specific lung density information into MRI-based attenuation maps is developed and compared with an approach that assumes uniform lung density. Methods: Five beagles were scanned with F-18-FDG PET/CT and MRI. The relationship between MRI and CT signal in the lungs was established, allowing the prediction of attenuation coefficients from MRI. MR images were segmented into air, lung, and soft tissue and converted into attenuation maps, some with constant lung density and some with patient-specific lung densities. The resulting PET images were compared by both global metrics of quantitative fidelity (accuracy, precision, and root mean squared error) and locally with relative error in volumes of interest. Results: A linear relationship was established between MRI and CT signal in the lungs. Constant lung density attenuation maps did not perform as well as patient-specific lung density attenuation maps, regardless of what constant density was chosen. In particular, when attenuation maps with patient-specific lung density were used, precision, accuracy, and root mean square error improved in lung tissue. In volumes of interest placed in the lungs, relative error was significantly reduced from a minimum of 12% to less than 5%. The benefit extended to tissues adjacent to the lungs but became less important as distance from the lungs increased. Conclusion: A means of using MRI to infer patient-specific attenuation coefficients in the lungs was developed and applied to augment whole-body MRI-based attenuation maps. This technique has been shown to improve the quantitative fidelity of PET images in the lungs and nearby tissues, compared with an approach that assumes uniform lung density.
引用
收藏
页码:977 / 984
页数:8
相关论文
共 50 条
  • [41] Motion Correction of Whole-Body PET Data with a Joint PET-MRI Registration Functional
    Michael Fieseler
    Fabian Gigengack
    Xiaoyi Jiang
    Klaus P Schäfers
    BioMedical Engineering OnLine, 13
  • [42] The impact of MR-guided PET attenuation correction on whole-body dynamic and parametric PET imaging
    Karakatsanis, Nicolas
    Tsoumpas, Charalampos
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [43] Impact of improved attenuation correction featuring a bone atlas and truncation correction on PET quantification in whole-body PET/MR
    Oehmigen, Mark
    Lindemann, Maike E.
    Gratz, Marcel
    Kirchner, Julian
    Ruhlmann, Verena
    Umutlu, Lale
    Blumhagen, Jan Ole
    Fenchel, Matthias
    Quick, Harald H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 (04) : 642 - 653
  • [44] Impact of improved attenuation correction featuring a bone atlas and truncation correction on PET quantification in whole-body PET/MR
    Mark Oehmigen
    Maike E. Lindemann
    Marcel Gratz
    Julian Kirchner
    Verena Ruhlmann
    Lale Umutlu
    Jan Ole Blumhagen
    Matthias Fenchel
    Harald H. Quick
    European Journal of Nuclear Medicine and Molecular Imaging, 2018, 45 : 642 - 653
  • [45] Whole-Body Functional MRI and PET/MRI in Multiple Myeloma
    Mule, Sebastien
    Reizine, Edouard
    Blanc-Durand, Paul
    Baranes, Laurence
    Zerbib, Pierre
    Burns, Robert
    Nouri, Refaat
    Itti, Emmanuel
    Luciani, Alain
    CANCERS, 2020, 12 (11) : 1 - 11
  • [46] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    David Izquierdo-Garcia
    Stephen J. Sawiak
    Karin Knesaurek
    Jagat Narula
    Valentin Fuster
    Joseph Machac
    Zahi A. Fayad
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 1574 - 1584
  • [47] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    Izquierdo-Garcia, David
    Sawiak, Stephen J.
    Knesaurek, Karin
    Narula, Jagat
    Fuster, Valentin
    Machac, Joseph
    Fayad, Zahi A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (08) : 1574 - 1584
  • [48] A deep learning-based approach for direct whole-body PET attenuation correction.
    Van Hemmen, Helena
    Massa, Haley
    Hurley, Samuel
    Cho, Steve
    Bradshaw, Tyler
    McMillan, Alan
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [49] Imaging inmultiplemyeloma. Skeletal survey, whole-body CT, whole-body MRI or PET?
    Mosebach, Jennifer
    Beuthien-Baumann, Bettina
    Schlemmer, Heinz-Peter
    Delorme, Stefan
    ONKOLOGE, 2018, 24 (08): : 584 - 595
  • [50] PISAC: A post-injection method for segmented attenuation correction in whole-body PET.
    Mix, M
    Nitzsche, EU
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 297P - 297P