Variable Lung Density Consideration in Attenuation Correction of Whole-Body PET/MRI

被引:38
|
作者
Marshall, Harry R. [1 ,2 ]
Prato, Frank S. [3 ]
Deans, Lela
Theberge, Jean [3 ]
Thompson, R. Terry [3 ]
Stodilka, Robert Z. [4 ]
机构
[1] Lawson Hlth Res Inst, Dept Imaging, Imaging Program, London, ON N6A 4V2, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] St Josephs Hlth Ctr, Dept Diagnost Imaging, London, ON, Canada
[4] London Hlth Sci Ctr, London, ON, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
PET/MRI; attenuation correction; lung density; segmentation; whole-body imaging; PET; SEGMENTATION; QUANTITATION; PERFUSION; SYSTEMS; TISSUE;
D O I
10.2967/jnumed.111.098350
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Present attenuation-correction algorithms in whole-body PET/MRI do not consider variations in lung density, either within or between patients; this may adversely affect accurate quantification. In this work, a technique to incorporate patient-specific lung density information into MRI-based attenuation maps is developed and compared with an approach that assumes uniform lung density. Methods: Five beagles were scanned with F-18-FDG PET/CT and MRI. The relationship between MRI and CT signal in the lungs was established, allowing the prediction of attenuation coefficients from MRI. MR images were segmented into air, lung, and soft tissue and converted into attenuation maps, some with constant lung density and some with patient-specific lung densities. The resulting PET images were compared by both global metrics of quantitative fidelity (accuracy, precision, and root mean squared error) and locally with relative error in volumes of interest. Results: A linear relationship was established between MRI and CT signal in the lungs. Constant lung density attenuation maps did not perform as well as patient-specific lung density attenuation maps, regardless of what constant density was chosen. In particular, when attenuation maps with patient-specific lung density were used, precision, accuracy, and root mean square error improved in lung tissue. In volumes of interest placed in the lungs, relative error was significantly reduced from a minimum of 12% to less than 5%. The benefit extended to tissues adjacent to the lungs but became less important as distance from the lungs increased. Conclusion: A means of using MRI to infer patient-specific attenuation coefficients in the lungs was developed and applied to augment whole-body MRI-based attenuation maps. This technique has been shown to improve the quantitative fidelity of PET images in the lungs and nearby tissues, compared with an approach that assumes uniform lung density.
引用
收藏
页码:977 / 984
页数:8
相关论文
共 50 条
  • [31] Diagnostic accuracy of whole-body PET/MRI and whole-body PET/CT for TNM staging in oncology
    Philipp Heusch
    Felix Nensa
    Benedikt Schaarschmidt
    Rupika Sivanesapillai
    Karsten Beiderwellen
    Benedikt Gomez
    Jens Köhler
    Henning Reis
    Verena Ruhlmann
    Christian Buchbender
    European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 42 - 48
  • [32] Diagnostic accuracy of whole-body PET/MRI and whole-body PET/CT for TNM staging in oncology
    Heusch, Philipp
    Nensa, Felix
    Schaarschmidt, Benedikt
    Sivanesapillai, Rupika
    Beiderwellen, Karsten
    Gomez, Benedikt
    Koehler, Jens
    Reis, Henning
    Ruhlmann, Verena
    Buchbender, Christian
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (01) : 42 - 48
  • [33] IMPROVED ACCURACY OF ATTENUATION CORRECTION IN WHOLE-BODY PET BY ADAPTIVE FILTERING OF TRANSMISSION PROFILES
    OSTERTAG, H
    KUBLER, WK
    DOLL, J
    STRAUSS, LG
    LORENZ, WJ
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (10) : 1751 - 1751
  • [34] Attenuation correction with extreme CT dose reduction for whole-body FDG PET/CT
    Christopfel, Rebecca
    Byrd, Darrin
    Alessio, Adam
    Asma, Evren
    De Man, Bruno
    Kinahan, Paul
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [35] Quantitative accuracy of MR-based attenuation correction in whole-body PET/MR
    Schramm, Georg
    Langner, Jens
    Hofheinz, Frank
    Baumann, Bettina Beuthien
    Platzek, Ivan
    Kotzerke, Jorg
    Steinbach, Joerg
    van den Hoff, Joerg
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [36] MR-based Attenuation Correction for a Whole-body Sequential PET/MR System
    Hu, Z.
    Ojha, N.
    Renisch, S.
    Schulz, V.
    Torres, I.
    Buhl, A.
    Pal, D.
    Muswick, G.
    Penatzer, J.
    Guo, T.
    Boenert, P.
    Tung, C.
    Kaste, J.
    Morich, M.
    Havens, T.
    Maniawski, P.
    Schaefer, W.
    Guenther, R. W.
    Krombach, G. A.
    Shao, L.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3508 - 3512
  • [37] Whole-body MR-based attenuation correction for PET using UTE Sequences
    Keereman, V.
    Fierens, Y.
    De Deene, Y.
    Vandenberghe, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S220 - S220
  • [38] Fuzzy clustering-based segmented attenuation correction in whole-body PET imaging
    Zaidi, H
    Diaz-Gomez, M
    Boudraa, A
    Slosman, DO
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (07): : 1143 - 1160
  • [39] New method for attenuation correction in whole-body PET studies with MRP reconstruction.
    Ruotsalainen, U
    Numminen, P
    Tolvanen, T
    Sutinen, E
    Alenius, S
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 302P - 302P
  • [40] Motion correction of whole-body PET data with a joint PET-MRI registration functional