Quantitative Analysis Tools and Digital Phantoms for Deformable Image Registration Quality Assurance

被引:9
|
作者
Kim, Haksoo [1 ]
Park, Samuel B. [2 ]
Monroe, James I. [1 ,3 ]
Traughber, Bryan J. [1 ,4 ]
Zheng, Yiran [1 ,4 ]
Lo, Simon S. [1 ,4 ]
Yao, Min [1 ,4 ]
Mansur, David [1 ,4 ]
Ellis, Rodney [1 ,4 ]
Machtay, Mitchell [1 ,4 ]
Sohn, Jason W. [1 ,4 ]
机构
[1] Case Western Reserve Univ, Sch Med, Dept Radiat Oncol, Cleveland, OH 44106 USA
[2] Natl Canc Ctr, Goyang Si, Gyeonggi Do, South Korea
[3] St Anthonys Med Ctr, St Louis, MO USA
[4] Univ Hosp Cleveland, Cleveland, OH 44106 USA
关键词
deformable image registration; quality assurance; FREE-FORM DEFORMATIONS; RADIATION-THERAPY; NONRIGID REGISTRATION; MUTUAL-INFORMATION; DEMONS ALGORITHM; MEDICAL IMAGES; B-SPLINES; MR-IMAGES; ACCURACY; OPTIMIZATION;
D O I
10.1177/1533034614553891
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This article proposes quantitative analysis tools and digital phantoms to quantify intrinsic errors of deformable image registration (DIR) systems and establish quality assurance (QA) procedures for clinical use of DIR systems utilizing local and global error analysis methods with clinically realistic digital image phantoms. Landmark-based image registration verifications are suitable only for images with significant feature points. To address this shortfall, we adapted a deformation vector field (DVF) comparison approach with new analysis techniques to quantify the results. Digital image phantoms are derived from data sets of actual patient images (a reference image set, R, a test image set, T). Image sets from the same patient taken at different times are registered with deformable methods producing a reference DVFref. Applying DVFref to the original reference image deforms T into a new image R. The data set, R, T, and DVFref, is from a realistic truth set and therefore can be used to analyze any DIR system and expose intrinsic errors by comparing DVFref and DVFtest. For quantitative error analysis, calculating and delineating differences between DVFs, 2 methods were used, (1) a local error analysis tool that displays deformation error magnitudes with color mapping on each image slice and (2) a global error analysis tool that calculates a deformation error histogram, which describes a cumulative probability function of errors for each anatomical structure. Three digital image phantoms were generated from three patients with a head and neck, a lung and a liver cancer. The DIR QA was evaluated using the case with head and neck.
引用
收藏
页码:428 / 439
页数:12
相关论文
共 50 条
  • [31] STANDARD TOOLS FOR ANALYSIS OF IMAGE QUALITY IN DIGITAL IMAGING
    MEIER, N
    FIEBICH, M
    RADIATION PROTECTION DOSIMETRY, 1995, 57 (1-4) : 141 - 143
  • [32] Evaluation of two quantitative ultrasound phantoms for use in daily quality assurance
    Gumy, C
    Alekxandrova, I
    Perron, C
    Slosman, DO
    Hans, D
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 : 14 - 14
  • [33] Evaluation of quantitative ultrasound phantoms for use in daily quality assurance.
    Fan, B
    Chen, MB
    Njeh, CF
    He, Y
    Diessel, E
    Wu, C
    Hans, D
    Fuerst, T
    Genant, HK
    JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 : S501 - S501
  • [34] Development of a dynamic deformable thorax phantom for the quality management of deformable image registration
    Sugawara, Yasuharu
    Kadoya, Noriyuki
    Kotabe, Kazuki
    Nakajima, Yujiro
    Ikeda, Ryutaro
    Tanabe, Shunpei
    Ohashi, Haruna
    Jingu, Keiichi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 100 - 107
  • [35] Visualization of Deformable Image Registration Quality Using Local Image Dissimilarity
    Schlachter, Matthias
    Fechter, Tobias
    Jurisic, Miro
    Schimek-Jasch, Tanja
    Oehlke, Oliver
    Adebahr, Sonja
    Birkfellner, Wolfgang
    Nestle, Ursula
    Buehler, Katja
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (10) : 2319 - 2328
  • [36] Dose sensitivity of three phantoms used for quality assurance in digital mammography
    Figl, M.
    Semturs, F.
    Kaar, M.
    Hoffmann, R.
    Kaldarar, H.
    Homolka, P.
    Mostbeck, G.
    Scholz, B.
    Hummel, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (02): : N13 - N23
  • [37] Semi-automated quality assurance of deformable registration in CT radiotherapy data
    Mcgrath, T.
    Lawrence, Z.
    Salih, R. Farhad
    Peters, Y.
    Rawling, J.
    Wilson, M.
    Piazzese, C.
    Holloway, S.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1171 - S1171
  • [38] Variability in commercially available deformable image registration: A multi-institution analysis using virtual head and neck phantoms
    Kubli, Alex
    Pukala, Jason
    Shah, Amish P.
    Kelly, Patrick
    Langen, Katja M.
    Bova, Frank J.
    Manon, Rafael R.
    Meeks, Sanford L.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (05): : 89 - 96
  • [39] Patient Specific Quantitative Assessment of Deformable Image Registration Quality Applied to Head and Neck Adaptive Therapy
    Gooding, M. J.
    Brouwer, C. L.
    Pickup, L. C.
    Sijtsema, N. M.
    Kadir, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3654 - 3654
  • [40] A fast and scalable method for quality assurance of deformable image registration on lung CT scans using convolutional neural networks
    Galib, Shaikat M.
    Lee, Hyoung K.
    Guy, Christopher L.
    Riblett, Matthew J.
    Hugo, Geoffrey D.
    MEDICAL PHYSICS, 2020, 47 (01) : 99 - 109