Quantitative Analysis Tools and Digital Phantoms for Deformable Image Registration Quality Assurance

被引:9
|
作者
Kim, Haksoo [1 ]
Park, Samuel B. [2 ]
Monroe, James I. [1 ,3 ]
Traughber, Bryan J. [1 ,4 ]
Zheng, Yiran [1 ,4 ]
Lo, Simon S. [1 ,4 ]
Yao, Min [1 ,4 ]
Mansur, David [1 ,4 ]
Ellis, Rodney [1 ,4 ]
Machtay, Mitchell [1 ,4 ]
Sohn, Jason W. [1 ,4 ]
机构
[1] Case Western Reserve Univ, Sch Med, Dept Radiat Oncol, Cleveland, OH 44106 USA
[2] Natl Canc Ctr, Goyang Si, Gyeonggi Do, South Korea
[3] St Anthonys Med Ctr, St Louis, MO USA
[4] Univ Hosp Cleveland, Cleveland, OH 44106 USA
关键词
deformable image registration; quality assurance; FREE-FORM DEFORMATIONS; RADIATION-THERAPY; NONRIGID REGISTRATION; MUTUAL-INFORMATION; DEMONS ALGORITHM; MEDICAL IMAGES; B-SPLINES; MR-IMAGES; ACCURACY; OPTIMIZATION;
D O I
10.1177/1533034614553891
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This article proposes quantitative analysis tools and digital phantoms to quantify intrinsic errors of deformable image registration (DIR) systems and establish quality assurance (QA) procedures for clinical use of DIR systems utilizing local and global error analysis methods with clinically realistic digital image phantoms. Landmark-based image registration verifications are suitable only for images with significant feature points. To address this shortfall, we adapted a deformation vector field (DVF) comparison approach with new analysis techniques to quantify the results. Digital image phantoms are derived from data sets of actual patient images (a reference image set, R, a test image set, T). Image sets from the same patient taken at different times are registered with deformable methods producing a reference DVFref. Applying DVFref to the original reference image deforms T into a new image R. The data set, R, T, and DVFref, is from a realistic truth set and therefore can be used to analyze any DIR system and expose intrinsic errors by comparing DVFref and DVFtest. For quantitative error analysis, calculating and delineating differences between DVFs, 2 methods were used, (1) a local error analysis tool that displays deformation error magnitudes with color mapping on each image slice and (2) a global error analysis tool that calculates a deformation error histogram, which describes a cumulative probability function of errors for each anatomical structure. Three digital image phantoms were generated from three patients with a head and neck, a lung and a liver cancer. The DIR QA was evaluated using the case with head and neck.
引用
收藏
页码:428 / 439
页数:12
相关论文
共 50 条
  • [21] A Novel Framework for Deformable Registration Evaluation and Quality Assurance
    Pirozzi, S.
    Piper, J.
    Nelson, A.
    Duchateau, M.
    Verellen, D.
    De Ridder, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S719 - S719
  • [22] Quality Assurance Parameters in Image Registration
    Maloney, K.
    MEDICAL PHYSICS, 2019, 46 (06) : E601 - E601
  • [23] Utilizing Deformable Image Registration and Quality Assurance to Automate Analysis of Anatomic Changes After Head and Neck Radiation Therapy
    Watkins, W.
    Sim, A. J.
    Chen, Q.
    Wilson, D. D.
    Read, P. W.
    Siebers, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : S98 - S99
  • [24] A Quantitative Evaluation of Velocity AI Deformable Image Registration
    Lin, H.
    Ayan, A.
    Zhai, H.
    Zhu, T.
    Both, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [25] Use of a DVH overlay technique for quality assurance of deformable image registration-based dose accumulation
    Kainz, Kristofer
    Garcia Alvarez, Juan
    Zhong, Hualiang
    Lim, Sara
    Ahunbay, Ergun
    Tai, An
    Erickson, Beth
    Lawton, Colleen
    Li, X. Allen
    MEDICAL PHYSICS, 2022, 49 (01) : 611 - 623
  • [26] Head-And-Neck Digital Phantoms for Geometric and Dosimetric Uncertainty Evaluation of CT-CBCT Deformable Image Registration
    Shen, Z.
    Bzdusek, K.
    Koyfman, S.
    Xia, P.
    MEDICAL PHYSICS, 2015, 42 (06) : 3292 - 3292
  • [27] Technical Note: Intensity-based quality assurance criteria for deformable image registration in image-guided radiotherapy
    Bosma, Lando S.
    Zachiu, Cornel
    Denis de Senneville, Baudouin
    Raaymakers, Bas W.
    Ries, Mario
    MEDICAL PHYSICS, 2023, 50 (09) : 5715 - 5722
  • [28] Image Registration II: TG132-Quality Assurance for Image Registration
    Brock, K.
    Mutic, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 453 - 454
  • [29] Development of Physiological-Based Virtual Thorax Phantoms for Evaluation of Deformable Image Registration
    Hu, L.
    Cui, T.
    Miller, W.
    Yin, F.
    Cai, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3655 - 3655
  • [30] Objective Assessment of the Quality and Accuracy of Deformable Image Registration
    Jurkovic, Ines-Ana
    Papanikolaou, Nikos
    Stathakis, Sotirios
    Kirby, Neil
    Mavroidis, Panayiotis
    JOURNAL OF MEDICAL PHYSICS, 2020, 45 (03) : 156 - 167