Quantitative Analysis Tools and Digital Phantoms for Deformable Image Registration Quality Assurance

被引:9
|
作者
Kim, Haksoo [1 ]
Park, Samuel B. [2 ]
Monroe, James I. [1 ,3 ]
Traughber, Bryan J. [1 ,4 ]
Zheng, Yiran [1 ,4 ]
Lo, Simon S. [1 ,4 ]
Yao, Min [1 ,4 ]
Mansur, David [1 ,4 ]
Ellis, Rodney [1 ,4 ]
Machtay, Mitchell [1 ,4 ]
Sohn, Jason W. [1 ,4 ]
机构
[1] Case Western Reserve Univ, Sch Med, Dept Radiat Oncol, Cleveland, OH 44106 USA
[2] Natl Canc Ctr, Goyang Si, Gyeonggi Do, South Korea
[3] St Anthonys Med Ctr, St Louis, MO USA
[4] Univ Hosp Cleveland, Cleveland, OH 44106 USA
关键词
deformable image registration; quality assurance; FREE-FORM DEFORMATIONS; RADIATION-THERAPY; NONRIGID REGISTRATION; MUTUAL-INFORMATION; DEMONS ALGORITHM; MEDICAL IMAGES; B-SPLINES; MR-IMAGES; ACCURACY; OPTIMIZATION;
D O I
10.1177/1533034614553891
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This article proposes quantitative analysis tools and digital phantoms to quantify intrinsic errors of deformable image registration (DIR) systems and establish quality assurance (QA) procedures for clinical use of DIR systems utilizing local and global error analysis methods with clinically realistic digital image phantoms. Landmark-based image registration verifications are suitable only for images with significant feature points. To address this shortfall, we adapted a deformation vector field (DVF) comparison approach with new analysis techniques to quantify the results. Digital image phantoms are derived from data sets of actual patient images (a reference image set, R, a test image set, T). Image sets from the same patient taken at different times are registered with deformable methods producing a reference DVFref. Applying DVFref to the original reference image deforms T into a new image R. The data set, R, T, and DVFref, is from a realistic truth set and therefore can be used to analyze any DIR system and expose intrinsic errors by comparing DVFref and DVFtest. For quantitative error analysis, calculating and delineating differences between DVFs, 2 methods were used, (1) a local error analysis tool that displays deformation error magnitudes with color mapping on each image slice and (2) a global error analysis tool that calculates a deformation error histogram, which describes a cumulative probability function of errors for each anatomical structure. Three digital image phantoms were generated from three patients with a head and neck, a lung and a liver cancer. The DIR QA was evaluated using the case with head and neck.
引用
收藏
页码:428 / 439
页数:12
相关论文
共 50 条
  • [1] Quality Assurance of Deformable Image Registration Algorithms: How Realistic Should Phantoms Be?
    Saenz, D.
    Kim, H.
    Chen, J.
    Stathakis, S.
    Kirby, N.
    MEDICAL PHYSICS, 2015, 42 (06) : 3286 - 3286
  • [2] Tools and recommendations for commissioning and quality assurance of deformable image registration in radiotherapy
    Bosma, Lando
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S124 - S124
  • [3] Tools and recommendations for commissioning and quality assurance of deformable image registration in radiotherapy
    Bosma, Lando S.
    Hussein, Mohammad
    Jameson, Michael G.
    Asghar, Soban
    Brock, Kristy K.
    McClelland, Jamie R.
    Poeta, Sara
    Yuen, Johnson
    Zachiu, Cornel
    Yeo, Adam U.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 32
  • [4] Quality Assurance of Deformable Image Registration in Radiotherapy
    Watkins, W. T.
    Bzdusek, K.
    Siebers, J. V.
    MEDICAL PHYSICS, 2014, 41 (06) : 399 - 399
  • [5] Quality assurance of deformable image registration for bowel motility quantification
    Nelissen, K. J.
    Barten, D. L. J.
    Laan, J. J.
    Westerveld, H.
    Bel, A.
    Van Kesteren, Z.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S958 - S958
  • [6] Accuracy of deformable image registration on magnetic resonance images in digital and physical phantoms
    Ger, Rachel B.
    Yang, Jinzhong
    Ding, Yao
    Jacobsen, Megan C.
    Fuller, Clifton D.
    Howell, Rebecca M.
    Li, Heng
    Jason Stafford, R.
    Zhou, Shouhao
    Court, Laurence E.
    MEDICAL PHYSICS, 2017, 44 (10) : 5153 - 5161
  • [7] Biomechanical quality assurance criteria for deformable registration in image guided radiotherapy
    Zachiu, C.
    de Senneville, B. Denis
    Ries, M.
    Raaymakers, B. W.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S310 - S311
  • [8] Building Deformation Error Histogram and Quality Assurance of Deformable Image Registration
    Park, S. B.
    Kim, H.
    Yao, M.
    Ellis, R.
    Machtay, M.
    Sohn, J. W.
    MEDICAL PHYSICS, 2012, 39 (06) : 3672 - 3672
  • [9] Deformable Image Registration Quality Assurance using Deep Learning Segmentation
    Mullins, Joel
    Wilson, Byron
    MEDICAL PHYSICS, 2022, 49 (08) : 5675 - 5675
  • [10] Quality assurance criteria and anatomically plausible models for deformable image registration
    Zachiu, C.
    de Senneville, B. Denis
    Raaymakers, B.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1093 - S1093