Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality

被引:34
|
作者
Komatsu, Sei [1 ]
Kamata, Teruaki [2 ]
Imai, Atsuko [1 ,3 ]
Ohara, Tomoki [1 ]
Takewa, Mitsuhiko [1 ]
Ohe, Ryoko [1 ]
Miyaji, Kazuaki [2 ]
Yoshida, Junichi [1 ]
Kodama, Kazuhisa [1 ]
机构
[1] Amagasaki Cent Hosp, Ctr Cardiovasc, Amagasaki, Hyogo 6610976, Japan
[2] Amagasaki Cent Hosp, Dept Diagnost Imaging, Amagasaki, Hyogo 6610976, Japan
[3] Osaka Univ, Sch Med, Dept Cardiol, Osaka, Japan
来源
关键词
Coronary computed tomography angiography; Contrast media; Tube potential; CT; PHANTOM; SINGLE;
D O I
10.1007/s10554-013-0201-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To analyze the invasiveness and image quality of coronary CT angiography (CCTA) with 80 kV. We enrolled 181 patients with low body weight and low calcium level. Of these, 154 patients were randomly assigned to 1 of 3 groups: 280 HU/80 kV (n = 51); 350 HU/80 kV (n = 51); or 350 HU/120 kV (n = 52). The amount of contrast media (CM) was decided with a CT number-controlling system. Twenty-seven patients were excluded because of an invalid time density curve by timing bolus. The predicted amount of CM, volume CT dose index, dose-length product, effective dose, image noise, and 5-point image quality were measured. The amounts of CM for the 80 kV/280 HU, 80 kV/350 HU, and 120 kV/350 HU groups were 10 +/- A 4 mL, 15 +/- A 7 mL, and 30 +/- A 6 mL, respectively. Although image noise was greater at 80 than 120 kV, there was no significant difference in image quality between 80 kV/350 HU and 120 kV/350 HU (p = 0.390). There was no significant difference in image quality between 80 kV/280 HU and 80 kV/350 HU (4.4 +/- A 0.7 vs. 4.7 +/- A 0.4, p = 0.056). The amount of CM and effective dose was lower for 80 kV CCTA than for 120 kV CCTA. CCTA at 80 kV/280 HU may decrease the amount of CM and radiation dose necessary while maintaining image quality.
引用
收藏
页码:1335 / 1340
页数:6
相关论文
共 50 条
  • [21] Dual-energy computed tomography pulmonary angiography with ultra-low dose contrast administration: Comparison of image quality with standard computed tomography pulmonary angiography
    Celtikci, Pinar
    Hekimoglu, Koray
    Kahraman, Gokhan
    Haberal, Kemal Murat
    Kilic, Dalokay
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 30 (04): : 549 - 556
  • [22] Coronary artery calcium scoring assessment in ultra-low-dose chest computed tomography
    Xiao, Huawei
    Wang, Xiangquan
    Yang, Panfeng
    Wang, Ling
    Xu, Jian
    CLINICAL IMAGING, 2024, 106
  • [23] Diagnostic Performance of Low Radiation Dose and Contrast-Dose Coronary Computed Tomography Angiography in the Detection of Coronary In-Stent Restenosis
    Du, Wang
    Fan, Zhanming
    Wang, Rui
    Xu, Lei
    Li, Jianying
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (08) : 1566 - 1572
  • [24] Low radiation dose computed tomography coronary angiography: evaluation of the variations in coronary arteries
    Nurullah Dogan
    Aydin Dursun
    Hakan Ozkan
    Serdar Karataş
    Nuran Celiloglu
    Fahriye Vatansever Agca
    Surgical and Radiologic Anatomy, 2016, 38 : 1123 - 1134
  • [25] Low radiation dose computed tomography coronary angiography: evaluation of the variations in coronary arteries
    Dogan, Nurullah
    Dursun, Aydin
    Ozkan, Hakan
    Karatas, Serdar
    Celiloglu, Nuran
    Agca, Fahriye Vatansever
    SURGICAL AND RADIOLOGIC ANATOMY, 2016, 38 (10) : 1123 - 1134
  • [26] Radiation dose and image quality in computed tomography
    Prokop, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (05): : 631 - 636
  • [27] Coronary computed tomography angiography with prospective electrocardiography triggering: a systematic review of image quality and radiation dose
    Sabarudin, Akmal
    Sun, Zhonghua
    Ng, Kwan-Hoong
    SINGAPORE MEDICAL JOURNAL, 2013, 54 (01) : 15 - 23
  • [28] Image quality and required radiation dose for coronary computed tomography angiography using an automatic tube potential selection technique
    Ying Wang
    Xiaohua Wang
    Yan Zhang
    Yuliu Lu
    Runze Wu
    Huishu Yuan
    The International Journal of Cardiovascular Imaging, 2014, 30 : 89 - 94
  • [29] Image quality and required radiation dose for coronary computed tomography angiography using an automatic tube potential selection technique
    Wang, Ying
    Wang, Xiaohua
    Zhang, Yan
    Lu, Yuliu
    Wu, Runze
    Yuan, Huishu
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 : 89 - 94
  • [30] Ultra-low-dose hybrid single photon emission computed tomography and coronary computed tomography angiography: a comprehensive and noninvasive diagnostic workup of suspected coronary artery disease
    Benz, Dominik C.
    Templin, Christian
    Kaufmann, Philipp A.
    Buechel, Ronny R.
    EUROPEAN HEART JOURNAL, 2015, 36 (47) : 3345 - 3345