Validation of human small airway measurements using endobronchial optical coherence tomography

被引:52
|
作者
Chen, Yu [1 ]
Ding, Ming [1 ]
Guan, Wei-jie [1 ]
Wang, Wei [2 ]
Luo, Wei-zhan [1 ]
Zhong, Chang-hao [1 ]
Jiang, Mei [1 ]
Jiang, Ju-hong [3 ]
Gu, Ying-ying [3 ]
Li, Shi-yue [1 ]
Zhong, Nan-shan [1 ]
机构
[1] Guangzhou Med Univ, Affiliated Hosp 1, Natl Clin Res Ctr Resp Dis, State Key Lab Resp Dis,Guangzhou Inst Resp Dis, Guangzhou, Guangdong, Peoples R China
[2] Guangzhou Med Univ, Affiliated Hosp 1, Dept Cardiol, Guangzhou, Guangdong, Peoples R China
[3] Guangzhou Med Univ, Affiliated Hosp 1, Dept Pathol, Guangzhou, Guangdong, Peoples R China
关键词
EB-OCT; Morphology; Small airways; MDCT; Histology; COMPUTED-TOMOGRAPHY; CT; ASTHMA; COPD;
D O I
10.1016/j.rmed.2015.09.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Small airway remodeling is the cardinal feature underlying chronic airway diseases. There is no modality which identifies small airway pathological changes, which is crucial for early diagnosis, efficacy and prognostic assessment. Objective: To evaluate the usefulness of endobronchial optical coherence tomography (EB-OCT) in assessing small airways morphology in vivo. Methods: Twelve patients with pulmonary nodules scheduled for lung resection underwent spirometry, multi-detector computed tomography (MDCT) and EB-OCT. We measured D-mean (mean luminal diameter), Ai (inner luminal area), Aw (airway wall area) and Aw% [Aw/(Ai + Aw) x 100%] from the 3rd to 5th generation bronchi of RB9 segment by MDCT. Dmean, Ai, Aw and Aw% from the 3rd to 9th generation bronchi of RB9 segment were measured by EB-OCT and histology. Correlations of these parameters, measured by three different methods, were evaluated. We recruited 4 COPD patients to determine if EB-OCT could identify peripheral airway remodeling. Results: The 4 parameters, measured by CT and EB-OCT, correlated significantly [D-mean (r = 0.991), Ai (r = 0.997), Aw (r = 0.997), Aw% (r = 0.991), all P < 0.01]. Significant correlation were found for these parameters, measured by histology and EB-OCT, from the 3rd to 5th generation bronchi [D-mean (r = 0.989), Ai (r = 0.997), Aw (r = 0.999), Aw% (r = 0.988), all P < 0.01], and from the 6th to 9th generation bronchi [D-mean (r = 0.979), Ai (r = 0.997), Aw (r = 0.994) and Aw% (r = 0.988), all P < 0.01]. Significant small airways morphological abnormalities were observed in COPD patients. Conclusions: EB-OCT, a minimally invasive imaging modality with high-resolution, is useful and clinically practical for assessing proximal and distal airways of human compared with CT and histology. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1446 / 1453
页数:8
相关论文
共 50 条
  • [41] Reproducibility of retinal thickness measurements using Optical Coherence Tomography
    Wang, RC
    Koozekanani, D
    Herderick, EE
    Roberts, C
    Katz, SE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S125 - S125
  • [42] Optical coherence tomography by using frequency measurements in wavelength domain
    Seck, Hon Luen
    Zhang, Ying
    Soh, Yeng Chai
    OPTICS EXPRESS, 2011, 19 (02): : 1324 - 1334
  • [43] Roughness measurements using optical coherence tomography: A preliminary study
    Hutiu, Gheorghe
    Dimb, Alexandru-Liviu
    Duma, Virgil-Florin
    Demian, Dorin
    Bradu, Adrian
    Podoleanu, Adrian Gh
    SEVENTH INTERNATIONAL CONFERENCE ON LASERS IN MEDICINE, 2018, 10831
  • [44] Astigmatism and optical coherence tomography measurements
    Young Hoon Hwang
    Sang Mok Lee
    Yong Yeon Kim
    Jong Yeon Lee
    Chungkwon Yoo
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2012, 250 : 247 - 254
  • [45] Astigmatism and optical coherence tomography measurements
    Hwang, Young Hoon
    Lee, Sang Mok
    Kim, Yong Yeon
    Lee, Jong Yeon
    Yoo, Chungkwon
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (02) : 247 - 254
  • [46] Oxygenation measurements with Optical Coherence Tomography
    Faber, DJ
    Mik, EG
    van der Meer, FJ
    Aalders, MCG
    van Leeuwen, TG
    PHOTON MIGRATION, OPTICAL COHERENCE TOMOGRAPHY, AND MICROSCOPY, 2001, 4431 : 20 - 24
  • [47] Characterisation of human skin using optical coherence tomography
    Gelikonov, V
    Sergeev, A
    Gelikonov, G
    Feldchtein, F
    Gladkova, N
    Ioannovich, J
    Fragia, K
    Pirza, T
    Zhegalov, Z
    Aleinik, D
    Vazina, I
    Snopova, L
    Antoniou, I
    OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING II, PROCEEDINGS OF, 1996, 2927 : 27 - 34
  • [48] Investigation of bacterial biofilm in the human middle ear using optical coherence tomography and acoustic measurements
    Nguyen, Cac T.
    Robinson, Sarah R.
    Jung, Woonggyu
    Novak, Michael A.
    Boppart, Stephen A.
    Allen, Jont B.
    HEARING RESEARCH, 2013, 301 : 193 - 200
  • [49] Airway Wall Thickness Measured In Small Airways In Vivo Using Optical Coherence Tomography (oct) In An Ovine Model
    Dalesio, N. M.
    Yuan, S. W.
    Mavadia-Shukla, J.
    Park, H.
    Li, X.
    Mitzner, W.
    Brown, R. H.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [50] Small Animal Ocular Biometry using Optical Coherence Tomography
    Ruggeri, Marco
    Kocaoglu, Omer
    Uhlhorn, Stephen
    Borja, David
    Urs, Raksha
    Chou, Tsung-Han
    Porciatti, Vittorio
    Parel, Jean-Marie
    Manns, Fabrice
    OPHTHALMIC TECHNOLOGIES XX, 2010, 7550