Validation of human small airway measurements using endobronchial optical coherence tomography

被引:52
|
作者
Chen, Yu [1 ]
Ding, Ming [1 ]
Guan, Wei-jie [1 ]
Wang, Wei [2 ]
Luo, Wei-zhan [1 ]
Zhong, Chang-hao [1 ]
Jiang, Mei [1 ]
Jiang, Ju-hong [3 ]
Gu, Ying-ying [3 ]
Li, Shi-yue [1 ]
Zhong, Nan-shan [1 ]
机构
[1] Guangzhou Med Univ, Affiliated Hosp 1, Natl Clin Res Ctr Resp Dis, State Key Lab Resp Dis,Guangzhou Inst Resp Dis, Guangzhou, Guangdong, Peoples R China
[2] Guangzhou Med Univ, Affiliated Hosp 1, Dept Cardiol, Guangzhou, Guangdong, Peoples R China
[3] Guangzhou Med Univ, Affiliated Hosp 1, Dept Pathol, Guangzhou, Guangdong, Peoples R China
关键词
EB-OCT; Morphology; Small airways; MDCT; Histology; COMPUTED-TOMOGRAPHY; CT; ASTHMA; COPD;
D O I
10.1016/j.rmed.2015.09.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Small airway remodeling is the cardinal feature underlying chronic airway diseases. There is no modality which identifies small airway pathological changes, which is crucial for early diagnosis, efficacy and prognostic assessment. Objective: To evaluate the usefulness of endobronchial optical coherence tomography (EB-OCT) in assessing small airways morphology in vivo. Methods: Twelve patients with pulmonary nodules scheduled for lung resection underwent spirometry, multi-detector computed tomography (MDCT) and EB-OCT. We measured D-mean (mean luminal diameter), Ai (inner luminal area), Aw (airway wall area) and Aw% [Aw/(Ai + Aw) x 100%] from the 3rd to 5th generation bronchi of RB9 segment by MDCT. Dmean, Ai, Aw and Aw% from the 3rd to 9th generation bronchi of RB9 segment were measured by EB-OCT and histology. Correlations of these parameters, measured by three different methods, were evaluated. We recruited 4 COPD patients to determine if EB-OCT could identify peripheral airway remodeling. Results: The 4 parameters, measured by CT and EB-OCT, correlated significantly [D-mean (r = 0.991), Ai (r = 0.997), Aw (r = 0.997), Aw% (r = 0.991), all P < 0.01]. Significant correlation were found for these parameters, measured by histology and EB-OCT, from the 3rd to 5th generation bronchi [D-mean (r = 0.989), Ai (r = 0.997), Aw (r = 0.999), Aw% (r = 0.988), all P < 0.01], and from the 6th to 9th generation bronchi [D-mean (r = 0.979), Ai (r = 0.997), Aw (r = 0.994) and Aw% (r = 0.988), all P < 0.01]. Significant small airways morphological abnormalities were observed in COPD patients. Conclusions: EB-OCT, a minimally invasive imaging modality with high-resolution, is useful and clinically practical for assessing proximal and distal airways of human compared with CT and histology. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1446 / 1453
页数:8
相关论文
共 50 条
  • [21] Endobronchial polarization sensitive optical coherence tomography for airway smooth muscle detection in pulmonary disease
    Soldati, Tatiana
    Vassileva, Sofi
    Vaselli, Margherita
    Kalverda, Kirsten
    Annema, Jouke
    Bonta, Peter
    De Boer, Johannes
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [22] Endobronchial optical coherence tomography helps to estimate the cartilage damage of the central airway in TBTB patients
    Zong, Kaican
    Liu, Bin
    Li, Shiying
    Li, Yishi
    Guo, Shuliang
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2023, 13
  • [23] Optical coherence tomography of the newborn airway
    Ridgway, James M.
    Su, Jianping
    Wright, Ryan
    Guo, Shuguang
    Kim, David C.
    Barretto, Roberto
    Ahuja, Gurpreet
    Sepehr, Ali
    Perez, Jorge
    Sills, Jack H.
    Chen, Zhongping
    Wong, Brian J. F.
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2008, 117 (05): : 327 - 334
  • [24] Evaluation of the Normal Airway Morphology Using Optical Coherence Tomography
    Su, Zhu-Quan
    Guan, Wei-Jie
    Li, Shi-Yue
    Feng, Jia-Xin
    Zhou, Zi-Qing
    Chen, Yu
    Zhong, Ming-Lu
    Zhong, Nan-Shan
    CHEST, 2019, 156 (05) : 915 - 925
  • [25] Airway wall thickness assessed using computed tomography and optical coherence tomography
    Coxson, Harvey O.
    Quiney, Brendan
    Sin, Don D.
    Xing, Li
    McWilliams, Annette M.
    Mayo, John R.
    Lam, Stephen
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2008, 177 (11) : 1201 - 1206
  • [26] Translating endobronchial optical coherence tomography to clinical practice
    Thiboutot, Jeffrey
    AMERICAN JOURNAL OF PHYSIOLOGY-LUNG CELLULAR AND MOLECULAR PHYSIOLOGY, 2024, 327 (01) : L1 - L2
  • [27] Endobronchial optical coherence tomography or computed tomography for evaluating progression of bronchiectasis
    Cheng, Lin-ling
    Guan, Wei-jie
    Zhong, Chang-hao
    Duan, Chong-yang
    Su, Zhu-quan
    Li, Shi-yue
    Zhong, Nan-shan
    ERJ OPEN RESEARCH, 2023, 9 (03)
  • [28] Optical coherence tomography for the identification and quantification of human airway wall layers
    Goorsenberg, Annika W. M.
    d'Hooghe, J. N. S.
    de Bruin, D. M.
    Roelofs, J. J. T. H.
    Annema, J. T.
    Bonta, P. I.
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [29] Optical coherence tomography for human airway wall layer identification and quantification
    d'Hooghe, Julia N. S.
    de Bruin, Daniel M.
    Roelofs, Joris J. T. H.
    Annema, Jouke T.
    Bonta, Peter I.
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [30] Respiratory gating of anatomical optical coherence tomography images of the human airway
    McLaughlin, Robert A.
    Armstrong, Julian J.
    Becker, Sven
    Walsh, Jennifer H.
    Jain, Arpit
    Hillman, David R.
    Eastwood, Peter R.
    Sampson, David D.
    OPTICS EXPRESS, 2009, 17 (08): : 6568 - 6577