Corrosion-Induced Cracking Time in Steel Fiber-Reinforced Concrete: Experiment and Finite Element Method

被引:7
|
作者
Paewchompoo, Nattapong [1 ]
Yodsudjai, Wanchai [2 ]
Chindaprasirt, Prinya [3 ]
机构
[1] Kasetsart Univ, Bangkok, Thailand
[2] Kasetsart Univ, Fac Engn, Dept Civil Engn, Bangkok, Thailand
[3] Khon Kaen Univ KKU, Civil Engn, Khon Kaen, Thailand
关键词
concrete cover cracking time; corrosion; corrosion current density; experimental study; fiber-reinforced concrete; finite element analysis; INDUCED COVER CRACKING; PREDICTION; MODEL; NONUNIFORM;
D O I
10.14359/51724620
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objective of this research was to clarify the mechanism of concrete cover crocking time due to reinforcement corrosion in steel fiber-reinforced concrete. An experimental study and analytical study were conducted. For the experimental study, 3 in. (76.2 mm) diameter and 6 in. (152.4 mm) length cylindrical concrete specimens with reinforcement placed in the middle were prepared. Conventional and steel-fiber-reinforced concrete with three levels of compressive strength were used in the study. A strain gauge was installed along the specimen's circumference and the corrosion of reinforcement was accelerated using anodic DC current. Concrete surface strain and impressed anodic current were recorded via a data logger and a multimeten respectively. Concrete cover cracking time was also investigated. After corrosion acceleration, reinforcement weight loss was evaluated and internal pressure due to the reinforcement corrosion product was calculated. The analytical study was conducted using finite element with four-node bilinear plane strain in a two-dimensional (2-D) model. In the finite element method (FEW) model, the reinforcement was removed and the internal pressure result from the expansion of corrosion products was applied, similar to the problem of cylinder under constant internal pressure. The relationship between concrete surface strain and internal pressure from the analytical study was compared with the experimental study. It was found that corrosion current density of the reinforcement embedded in thefiber-reinforced concrete was higher than that of conventional concrete. Concrete cover cracking time increased with increase of concrete tensile strength. In addition, the relationship between concrete surface strain and the internal pressure could be predicted by the FM results within an acceptable margin of error.
引用
收藏
页码:3 / 12
页数:10
相关论文
共 50 条
  • [31] Experimental Investigation of Corrosion-Induced Cover Cracking in Reinforced Concrete Structures
    Lu, Chunhua
    Jin, Weiliang
    Mao, Jianghong
    NEW AND ADVANCED MATERIALS, PTS 1 AND 2, 2011, 197-198 : 1690 - +
  • [32] Creep Effect on Time to Corrosion-Induced Cracking of Concrete Cover
    Baji, Hassan
    Yang, Wei
    Li, Chun-Qing
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2024, 22 (09) : 1587 - 1603
  • [33] Nonuniform Corrosion-Induced Stresses in Steel-Reinforced Concrete
    Xia, Ning
    Ren, Qingwen
    Liang, Robert Y.
    Payer, Joe
    Patnaik, Anil
    JOURNAL OF ENGINEERING MECHANICS, 2012, 138 (04) : 338 - 346
  • [34] Experimental and probabilistic analysis of time to corrosion-induced cover cracking for marine reinforced concrete structures
    Lu, Chunhua
    Yuan, Siqi
    Liu, Ronggui
    CORROSION ENGINEERING SCIENCE AND TECHNOLOGY, 2017, 52 (02) : 124 - 133
  • [35] Prediction of Corrosion-Induced Longitudinal Cracking Time of Concrete Cover Surface of Reinforced Concrete Structures under Load
    Wang, Jian
    Yuan, Yongyu
    Xu, Qiang
    Qin, Hongtu
    MATERIALS, 2022, 15 (20)
  • [36] Influence of corrosion-induced cracking on structural behavior of reinforced concrete arch ribs
    Ma, Yafei
    Xu, Fuyou
    Wang, Lei
    Zhang, Jianren
    Zhang, Xuhui
    ENGINEERING STRUCTURES, 2016, 117 : 184 - 194
  • [37] Effect of tropical marine microclimates on depassivation and corrosion-induced cracking of reinforced concrete
    Cabrera-Madrid, J. A.
    Balancan-Zapata, M.
    Torres-Acosta, A. A.
    Castro-Borges, P.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (12): : 8211 - 8225
  • [38] Corrosion-induced deterioration and fracture mechanisms in ultra fiber-reinforced concretet
    Song, Zhaoping
    Li, Shaohua
    Cheng, Lulu
    Yu, Qingliang
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 423
  • [39] Modelling of Non-Uniform Corrosion-Induced Cover Cracking in Reinforced Concrete
    Guzman, Santiago
    Galvez, Jaime C.
    Sancho, Jose M.
    CONCREEP 10: MECHANICS AND PHYSICS OF CREEP, SHRINKAGE, AND DURABILITY OF CONCRETE AND CONCRETE STRUCTURES, 2015, : 426 - 434
  • [40] Prediction of extent and liklihood of corrosion-induced cracking in reinforced concrete bridge decks
    Firouzi, Afshin
    Rahai, Ali Reza
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2011, 9 (03) : 183 - 192