Corrosion-Induced Cracking Time in Steel Fiber-Reinforced Concrete: Experiment and Finite Element Method

被引:7
|
作者
Paewchompoo, Nattapong [1 ]
Yodsudjai, Wanchai [2 ]
Chindaprasirt, Prinya [3 ]
机构
[1] Kasetsart Univ, Bangkok, Thailand
[2] Kasetsart Univ, Fac Engn, Dept Civil Engn, Bangkok, Thailand
[3] Khon Kaen Univ KKU, Civil Engn, Khon Kaen, Thailand
关键词
concrete cover cracking time; corrosion; corrosion current density; experimental study; fiber-reinforced concrete; finite element analysis; INDUCED COVER CRACKING; PREDICTION; MODEL; NONUNIFORM;
D O I
10.14359/51724620
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objective of this research was to clarify the mechanism of concrete cover crocking time due to reinforcement corrosion in steel fiber-reinforced concrete. An experimental study and analytical study were conducted. For the experimental study, 3 in. (76.2 mm) diameter and 6 in. (152.4 mm) length cylindrical concrete specimens with reinforcement placed in the middle were prepared. Conventional and steel-fiber-reinforced concrete with three levels of compressive strength were used in the study. A strain gauge was installed along the specimen's circumference and the corrosion of reinforcement was accelerated using anodic DC current. Concrete surface strain and impressed anodic current were recorded via a data logger and a multimeten respectively. Concrete cover cracking time was also investigated. After corrosion acceleration, reinforcement weight loss was evaluated and internal pressure due to the reinforcement corrosion product was calculated. The analytical study was conducted using finite element with four-node bilinear plane strain in a two-dimensional (2-D) model. In the finite element method (FEW) model, the reinforcement was removed and the internal pressure result from the expansion of corrosion products was applied, similar to the problem of cylinder under constant internal pressure. The relationship between concrete surface strain and internal pressure from the analytical study was compared with the experimental study. It was found that corrosion current density of the reinforcement embedded in thefiber-reinforced concrete was higher than that of conventional concrete. Concrete cover cracking time increased with increase of concrete tensile strength. In addition, the relationship between concrete surface strain and the internal pressure could be predicted by the FM results within an acceptable margin of error.
引用
收藏
页码:3 / 12
页数:10
相关论文
共 50 条
  • [21] Simulation of Corrosion-Induced Cracking of Reinforced Concrete Based on Fracture Phase Field Method
    Xia, Xiaozhou
    Qin, Changsheng
    Lu, Guangda
    Gu, Xin
    Zhang, Qing
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2024, 138 (03): : 2257 - 2276
  • [22] Control of corrosion-induced damage in reinforced concrete beams using carbon fiber-reinforced polymer laminates
    Badawi, M
    Soudki, K
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2005, 9 (02) : 195 - 201
  • [23] Investigation on corrosion-induced cracking and corrosion expansive pressure in reinforced concrete members
    Hu Z.
    Xia L.
    Cheng C.
    Li B.
    Xu B.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2020, 52 (03): : 99 - 105
  • [24] Modeling the time-to-corrosion cracking of reinforced concrete structures by finite element
    Castorena, J. H.
    Almeraya-Calderon, F.
    Velasquez, J. I.
    Gaona-Tiburcio, C.
    Cardenas, A. I.
    Barrios-Durstewitz, C.
    Leon, L. Lopez
    Martinez-Villafane, A.
    CORROSION, 2008, 64 (07) : 600 - 606
  • [25] Modelling the corrosion-induced cracking of reinforced concrete structures exposed to the atmosphere
    L'Hostis, V.
    Millard, A.
    Perrin, S.
    Burger, E.
    Neff, D.
    Dillmann, P.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2011, 62 (10): : 943 - 947
  • [26] State-of-art of corrosion-induced cracking of reinforced concrete structures
    Zhao, Yuxi
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2013, 43 (05): : 1122 - 1134
  • [27] Monitoring corrosion-induced concrete cracking adjacent to the steel-concrete interface
    Alhede, Andreas
    Dijkstra, Jelke
    Lundgren, Karin
    MATERIALS AND STRUCTURES, 2023, 56 (09)
  • [28] Monitoring corrosion-induced concrete cracking adjacent to the steel-concrete interface
    Andreas Alhede
    Jelke Dijkstra
    Karin Lundgren
    Materials and Structures, 2023, 56
  • [29] Nonlinear finite element analysis of steel fiber-reinforced concrete coupling beams
    Kim, S-W.
    Yun, H-D.
    Jang, S-J.
    Park, W-S.
    Jang, Y-I.
    Choi, C-S.
    COMPUTATIONAL MODELLING OF CONCRETE STRUCTURES. EURO-C 2018, 2018, : 889 - 893
  • [30] Corrosion-Induced Cracking in Reinforced Concrete due to Chloride Contamination and Ingress
    Chen, E.
    Tang, Shengwen
    Leung, Christopher K. Y.
    ACI MATERIALS JOURNAL, 2019, 116 (05) : 99 - 111