A portable blood plasma clot micro-elastometry device based on resonant acoustic spectroscopy

被引:2
|
作者
Krebs, C. R. [1 ]
Li, Ling [2 ]
Wolberg, Alisa S. [3 ]
Oldenburg, Amy L. [1 ,2 ]
机构
[1] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Dept Pathol & Lab Med, Chapel Hill, NC 27599 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2015年 / 86卷 / 07期
基金
美国国家卫生研究院;
关键词
PLATELET CONTRACTILE-FORCE; MECHANICAL-PROPERTIES; THROMBIN GENERATION; HEPARIN CONCENTRATION; FIBRIN STRUCTURE; ELASTIC-MODULUS; MANAGEMENT;
D O I
10.1063/1.4926543
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Abnormal blood clot stiffness is an important indicator of coagulation disorders arising from a variety of cardiovascular diseases and drug treatments. Here, we present a portable instrument for elastometry of microliter volume blood samples based upon the principle of resonant acoustic spectroscopy, where a sample of well-defined dimensions exhibits a fundamental longitudinal resonance mode proportional to the square root of the Young's modulus. In contrast to commercial thromboelastography, the resonant acoustic method offers improved repeatability and accuracy due to the high signal-to-noise ratio of the resonant vibration. We review the measurement principles and the design of a magnetically actuated microbead force transducer applying between 23 pN and 6.7 nN, providing a wide dynamic range of elastic moduli (3 Pa-27 kPa) appropriate for measurement of clot elastic modulus (CEM). An automated and portable device, the CEMport, is introduced and implemented using a 2 nm resolution displacement sensor with demonstrated accuracy and precision of 3% and 2%, respectively, of CEM in biogels. Importantly, the small strains (<0.13%) and low strain rates (<1/s) employed by the CEMport maintain a linear stress-to-strain relationship which provides a perturbative measurement of the Young's modulus. Measurements of blood plasma CEM versus heparin concentration show that CEMport is sensitive to heparin levels below 0.050 U/ml, which suggests future applications in sensing heparin levels of post-surgical cardiopulmonary bypass patients. The portability, high accuracy, and high precision of this device enable new clinical and animal studies for associating CEM with blood coagulation disorders, potentially leading to improved diagnostics and therapeutic monitoring. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Elastometry of clot phantoms via magnetomotive ultrasound-based resonant acoustic spectroscopy
    Levy, Benjamin E.
    Oldenburg, Amy L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (15):
  • [2] High Sensitivity Micro-Elastometry: Applications in Blood Coagulopathy
    Gongting Wu
    Charles R. Krebs
    Feng-Chang Lin
    Alisa S. Wolberg
    Amy L. Oldenburg
    Annals of Biomedical Engineering, 2013, 41 : 2120 - 2129
  • [3] High Sensitivity Micro-Elastometry: Applications in Blood Coagulopathy
    Wu, Gongting
    Krebs, Charles R.
    Lin, Feng-Chang
    Wolberg, Alisa S.
    Oldenburg, Amy L.
    ANNALS OF BIOMEDICAL ENGINEERING, 2013, 41 (10) : 2120 - 2129
  • [4] Micro-elastometry on whole blood clots using actuated surface-attached posts (ASAPs)
    Judith, Robert M.
    Fisher, Jay K.
    Spero, Richard Chasen
    Fiser, Briana L.
    Turner, Adam
    Oberhardt, Bruce
    Taylor, R. M.
    Falvo, Michael R.
    Superfine, Richard
    LAB ON A CHIP, 2015, 15 (05) : 1385 - 1393
  • [5] Development of a plasma separation system for a portable blood test device
    Kuroda, Chiaki
    Ohki, Yoshimichi
    Ashiba, Hiroki
    Fujimaki, Makoto
    Awazu, Koichi
    Tanaka, Torahiko
    Makishima, Makoto
    IEEJ Transactions on Sensors and Micromachines, 2015, 135 (05) : 152 - 157
  • [6] Integration of Acoustic Radiation Force and Optical Imaging for Blood Plasma Clot Stiffness Measurement
    Wang, Caroline W.
    Perez, Matthew J.
    Helmke, Brian P.
    Viola, Francesco
    Lawrence, Michael B.
    PLOS ONE, 2015, 10 (06):
  • [7] Detection of Micro-Bubbles in Thin Polymer Films by Means of Acoustic Resonant Spectroscopy
    Tohmyoh, Hironori
    Ikarashi, Hidetomo
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2013, 52 (02)
  • [8] Integral design of a micro acoustic wave based sensor device
    Lubking, GW
    Jakoby, B
    Vellekoop, MJ
    SMART STRUCTURES AND MATERIALS 1998: SMART ELECTRONICS AND MEMS, 1998, 3328 : 265 - 273
  • [9] Resonant Acoustic Tweezing Spectroscopy for Small-Volume Noncontact Assessment of Blood Coagulation
    Kasireddy, Nithya
    Orie, Jeremy C.
    Khismatullin, Damir
    BLOOD, 2018, 132
  • [10] Portable Device Based on Microwave Resonator for Noninvasive Blood Glucose Monitoring
    Garcia, Hector
    Juan, Carlos G.
    Avila-Navarro, Ernesto
    Bronchalo, Enrique
    Sabater-Navarro, Jose M.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 1115 - 1118