Uncertainty calculation in the calibration of an infusion pump using the comparison method

被引:0
|
作者
Furtado, A. [1 ]
Batista, E. [1 ]
Ferreira, M. C. [1 ]
Godinho, I [1 ]
Lucas, Peter [2 ]
机构
[1] Portuguese Inst Qual, IPQ, P-2828513 Caparica, Portugal
[2] Dutch Metrol Inst, VSL, NL-2629 JA Delft, Netherlands
关键词
medical infusion instruments; flow; calibration; uncertainty;
D O I
暂无
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
Nowadays, several types of infusion pumps are commonly used for drug delivery, such as syringe pumps and peristaltic pumps. These instruments present different measuring features and capacities according to their use and therapeutic application. In order to ensure the metrological traceability of these flow and volume measuring instruments it is necessary to use suitable calibration methods and standards. Two different calibration methods can be used to determine the flow error of infusion pumps. One is the gravimetric method, considered as a primary method and commonly used by National Metrology Institutes. The other is a comparison method where an Infusion Device Analyser (IDA) is used as flow generator, and is typically used in hospital maintenance offices. The uncertainty calculation for the gavimetric method is very well described in the literature but for the comparison method no information regarding the uncertainty evaluation and components is available. This paper will describe in detail the measurement model along with the standard uncertainties components, the sensitivity coefficients values, the combined standard uncertainty and the expanded uncertainty of the comparison calibration method using an IDA, considering GUM methodology. This work has been developed in the framework of the EURAMET EMRP MeDD (HLT07) and EMPIR InfusionUptake (15SIP03) projects.
引用
收藏
页码:186 / 191
页数:6
相关论文
共 50 条
  • [31] Uncertainty Improvement of Monopole Antenna Calibration Using Equivalent Capacitance Substitution Method
    Kim, Jeong-Hwan
    Park, Jeong-Il
    Kang, Jin-Seob
    Kang, Tae-Weon
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,
  • [32] Uncertainty Evaluation and Validation of a Comparison Methodology to Perform In-house Calibration of Platinum Resistance Thermometers using a Monte Carlo Method
    A. Silva Ribeiro
    J. Alves e Sousa
    C. Oliveira Costa
    M. Pimenta Castro
    M. G. Cox
    International Journal of Thermophysics, 2008, 29 : 902 - 914
  • [33] Uncertainty evaluation and validation of a comparison methodology to perform in-house calibration of platinum resistance thermometers using a Monte Carlo Method
    Ribeiro, A. Silva
    Alves e Sousa, J.
    Costa, C. Oliveira
    Castro, M. Pimenta
    Cox, M. G.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2008, 29 (03) : 902 - 914
  • [34] Brazilian perfusionists and arterial roller pump adjustment: comparison between static and dynamic calibration method
    Vieira Junior, Francisco Ubaldo
    Antunes, Nilson
    de Medeiros Junior, Johannes Dantas
    Vieira, Reinaldo Wilson
    de Carvalho Filho, Elio Barreto
    Cavalcante Reis Junior, Jose Evaldo
    Costa, Eduardo Tavares
    REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2011, 26 (02): : 205 - 212
  • [35] Calibration method of microscope and its measurement uncertainty
    Bao Jian-ping
    Wang Hui-sheng
    Zhang Xiao-fei
    Third International Symposium on Precision Mechanical Measurements, Pts 1 and 2, 2006, 6280 : U706 - U712
  • [36] A calculation and uncertainty evaluation method for the effective area of a piston rod used in quasi-static pressure calibration
    Gu, Tingwei
    Kong, Deren
    Shang, Fei
    Chen, Jing
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (04)
  • [37] Estimation of calibration uncertainty of OCM-3 and its comparison with OCM-2 using preflight radiometric calibration
    Seth, Harish
    Singh, Amit Kumar
    Adlakha, Dheeraj
    Sharma, B. N.
    Sarkar, Arti
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2024,
  • [38] Calculation method for the Profile Curves of Cycloidal Pump
    Wu Yangfang
    Xia Chunlin
    Shi Yonggang
    FRONTIER IN FUNCTIONAL MANUFACTURING TECHNOLOGIES, 2010, 136 : 126 - +
  • [39] Calculation Method for the Theoretical Displacement of Cycloidal Pump
    Wu, Yangfang
    Xia, Chunlin
    Shi, Yonggang
    ADVANCES IN ENGINEERING DESIGN AND OPTIMIZATION, PTS 1 AND 2, 2011, 37-38 : 242 - +
  • [40] Uncertainty Calculation of the D-Band Power Meter Calibration Factor
    Shimaoka, Kazuhiro
    Kinoshita, Moto
    Fujii, Katsumi
    Tosaka, Toshihide
    2014 39TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2014,