Uncertainty calculation in the calibration of an infusion pump using the comparison method

被引:0
|
作者
Furtado, A. [1 ]
Batista, E. [1 ]
Ferreira, M. C. [1 ]
Godinho, I [1 ]
Lucas, Peter [2 ]
机构
[1] Portuguese Inst Qual, IPQ, P-2828513 Caparica, Portugal
[2] Dutch Metrol Inst, VSL, NL-2629 JA Delft, Netherlands
关键词
medical infusion instruments; flow; calibration; uncertainty;
D O I
暂无
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
Nowadays, several types of infusion pumps are commonly used for drug delivery, such as syringe pumps and peristaltic pumps. These instruments present different measuring features and capacities according to their use and therapeutic application. In order to ensure the metrological traceability of these flow and volume measuring instruments it is necessary to use suitable calibration methods and standards. Two different calibration methods can be used to determine the flow error of infusion pumps. One is the gravimetric method, considered as a primary method and commonly used by National Metrology Institutes. The other is a comparison method where an Infusion Device Analyser (IDA) is used as flow generator, and is typically used in hospital maintenance offices. The uncertainty calculation for the gavimetric method is very well described in the literature but for the comparison method no information regarding the uncertainty evaluation and components is available. This paper will describe in detail the measurement model along with the standard uncertainties components, the sensitivity coefficients values, the combined standard uncertainty and the expanded uncertainty of the comparison calibration method using an IDA, considering GUM methodology. This work has been developed in the framework of the EURAMET EMRP MeDD (HLT07) and EMPIR InfusionUptake (15SIP03) projects.
引用
收藏
页码:186 / 191
页数:6
相关论文
共 50 条
  • [21] Administration of I-131-Metaiodobenzylguanidine Using the Peristaltic Infusion Pump Method
    de la Guardia, Miguel
    McCammon, Steven
    Nielson, Karen
    Granger, Meaghan
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2014, 42 (02) : 109 - 113
  • [22] The Research on Calculation Method of Pump Efficiency
    Li, Qiang
    Yin, Xudong
    FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY II, PTS 1 AND 2, 2012, 503-504 : 968 - 971
  • [23] Uncertainty calculation for AMN impedance contribution using the Monte Carlo Method
    Kriz, Alexander
    2019 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, SIGNAL AND POWER INTEGRITY (EMC+SIPI), 2019, : 565 - 569
  • [24] CALCULATION OF EXPECTATION VALUES AND UNCERTAINTY FOR LINEAR POTENTIAL BY USING NUMEROV METHOD
    Bircan, H.
    Calik, A. E.
    Manisa, K.
    ROMANIAN JOURNAL OF PHYSICS, 2020, 65 (1-2):
  • [25] Uncertainty quantification in the calculation of keff using sensitity and stochastic sampling method
    Hu Ze-Hua
    Ye Tao
    Liu Xiong-Guo
    Wang Jia
    ACTA PHYSICA SINICA, 2017, 66 (01)
  • [26] Uncertainty calculation for spacecraft thermal models using a generalized SEA method
    Gomez-San-Juan, Alejandro
    Perez-Grande, Isabel
    Sanz-Andres, Angel
    ACTA ASTRONAUTICA, 2018, 151 : 691 - 702
  • [27] A METHOD FOR IMPLEMENTING PROGRAMMED INFUSION OF THIOPENTONE AND METHOHEXITONE WITH A SIMPLE INFUSION PUMP
    CRANKSHAW, DP
    KARASAWA, F
    ANAESTHESIA AND INTENSIVE CARE, 1989, 17 (04) : 496 - 499
  • [28] Uncertainty Calculation Method for Photodiode Pyranometers
    Forstinger, Anne
    Wilbert, Stefan
    Driesse, Anton
    Kraas, Birk
    SOLAR RRL, 2022, 6 (05)
  • [29] CALIBRATION PROCEDURE FOR STABILIZED LASERS USING THE METHOD OF OPTICAL BEATS MEASUREMENT UNCERTAINTY
    Dugheanu, Elena
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN-SERIES A-APPLIED MATHEMATICS AND PHYSICS, 2007, 69 (01): : 63 - 70
  • [30] Calibration procedure for stabilized lasers using the method of optical beats measurement uncertainty
    National Institute of Metrology, Bucharest, Romania
    UPB Sci Bull Ser A, 2007, 1 (63-70): : 63 - 70