Biomechanical evaluation of stand-alone lumbar polyether-ether-ketone interbody cage with integrated screws

被引:38
|
作者
Kornblum, Martin B. [1 ]
Turner, Alexander W. L. [2 ]
Cornwall, G. Bryan [2 ]
Zatushevsky, Michael A. [2 ]
Phillips, Frank M. [3 ]
机构
[1] Mendelson Kornblum Orthopaed & Spine Surg, Warren, MI 48093 USA
[2] NuVasive Inc, San Diego, CA 92121 USA
[3] Rush Univ, Med Ctr, Dept Orthoped Surg, Midwest Orthopaed, Chicago, IL 60612 USA
来源
SPINE JOURNAL | 2013年 / 13卷 / 01期
关键词
Biomechanics; Lumbar; ALIF; Interbody fusion; Fixation; PEDICLE SCREWS; VASCULAR INJURY; IN-VITRO; INVITED SUBMISSION; PERIPHERAL-NERVES; SPINAL-FUSION; MARCH; 2005; FIXATION; PLATE; STABILITY;
D O I
10.1016/j.spinee.2012.11.013
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Stand-alone interbody cages with integrated screws potentially provide a biomechanically stable solution for anterior lumbar interbody fusion (ALIF) that alleviates the need for additional exposure for supplemental fixation, thereby reducing the chance of additional complications and morbidity. PURPOSE: To compare the stability of a stand-alone anterior interbody fusion system with integrated fixation screws against traditional supplemental fixation methods and to evaluate the difference between three and four fixation screws in the stand-alone cage. STUDY DESIGN: In vitro cadaveric biomechanical study. METHODS: Eight cadaveric lumbar spines (L2-sacrum) were tested using a flexibility protocol consisting of three cycles to +/- 7.5 Nm in flexion-extension, lateral bending, and axial rotation. The conditions evaluated were intact spine; polyether-ether-ketone cage (zero integrated screws) at L4-L5; cage (zero screws) + bilateral pedicle screws (PS); cage (three screws); cage (four screws); cage (zero screws) + anterior plate; and cage (three screws) + spinous process plate. Motion at the index level was assessed using an optoelectronic system. RESULTS: The cage without integrated screws reduced the motion in flexion-extension and lateral bending (p < .001) compared with that in the intact spine. In axial rotation, mean range of motion (ROM) was 8% greater than in intact spine (p > .962). The addition of three integrated screws reduced ROM significantly compared with the cage without screws in all motion planes (p < .001). A fourth screw had no statistically significant effect on the ROM, although there was a trend toward less motion with four screws compared with three. In flexion-extension, the cage with three integrated screws and the spinous process plate was the most rigid condition. There was no significant difference from the bilateral PS (p = .537); however, this was more rigid than all other conditions (p < .024). The most stable condition in lateral bending and axial rotation was the cage with bilateral PS. In lateral bending, the cage (three or four screws) was not significantly different from the cage with anterior plate or the cage (three screws) with spinous process plate fixation; however, only the latter condition was statistically comparable with bilateral PS. In axial rotation, there were no significant differences between the conditions that included integrated screws or supplemental fixation (p > .081). CONCLUSIONS: Biomechanical testing revealed that the stand-alone cage with integrated screws provides more immediate stability than a cage alone and provides equivalent stability to ALIF constructs with supplemental fixation in lateral bending and axial rotation. Additional flexion-extension rigidity of the anterior cage maybe realized by the addition of a spinous process plate that was found to be as stable as supplemental bilateral PS. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:77 / 84
页数:8
相关论文
共 50 条
  • [41] Hounsfield unit value on CT as a predictor of cage subsidence following stand-alone oblique lumbar interbody fusion for the treatment of degenerative lumbar diseases
    Zhou, Jing
    Yuan, Chao
    Liu, Chao
    Zhou, Lei
    Wang, Jian
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [42] Applying the Mini-Open Anterolateral Lumbar Interbody Fusion with Self-Anchored Stand-Alone Polyetheretherketone Cage in Lumbar Revision Surgery
    Kuang, Lei
    Chen, Yuqiao
    Li, Lei
    Lu, Guohua
    Wang, Bing
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [43] Hounsfield unit value on CT as a predictor of cage subsidence following stand-alone oblique lumbar interbody fusion for the treatment of degenerative lumbar diseases
    Jing Zhou
    Chao Yuan
    Chao Liu
    Lei Zhou
    Jian Wang
    BMC Musculoskeletal Disorders, 22
  • [44] Biomechanical Evaluation of Stand-Alone Oblique Lateral Lumbar Interbody Fusion Under 3 Different Bone Mineral Density Conditions: A Finite Element Analysis
    Wang, Zemin
    Ma, Rong
    Cai, Zecheng
    Wang, Zhiqiang
    Yang, Shulong
    Ge, Zhaohui
    WORLD NEUROSURGERY, 2021, 155 : E285 - E293
  • [45] Rate of Revision Surgery After Stand-alone Lateral Lumbar Interbody Fusion for Lumbar Spinal Stenosis
    Nemani, Venu M.
    Aichmair, Alexander
    Taher, Fadi
    Lebl, Darren R.
    Hughes, Alexander P.
    Sama, Andrew A.
    Cammisa, Frank P.
    Girardi, Federico P.
    SPINE, 2014, 39 (05) : E326 - E331
  • [46] The effect of sarcopenia in the clinical outcomes following stand-alone lateral lumbar interbody fusion
    Li, Hao
    Li, Jun
    Ma, Yaojing
    Li, Fangcai
    Xu, Zhengkuan
    Chen, Qixin
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2021, 34 (03) : 469 - 476
  • [47] Incidence and impact of implant subsidence after stand-alone lateral lumbar interbody fusion
    Bocahut, N.
    Audureau, E.
    Poignard, A.
    Delambre, J.
    Queinnecc, S.
    Lachaniette, C. -H. Flouzat
    Allain, J.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (03) : 405 - 410
  • [48] Stand-alone anterior lumbar interbody fusion: indications, techniques, surgical outcomes and complications
    Kerolus, Mena
    Turel, Mazda K.
    Tan, Lee
    Deutsch, Harel
    EXPERT REVIEW OF MEDICAL DEVICES, 2016, 13 (12) : 1127 - 1136
  • [49] Stand-alone minimally invasive lateral lumbar interbody fusion: Multicenter clinical outcomes
    Ahmadian, Arnir
    Bach, Konrad
    Bolinger, Bryan
    Malham, Gregory M.
    Okonkwo, David O.
    Kanter, Adam S.
    Uribe, Juan S.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2015, 22 (04) : 740 - 746
  • [50] Perioperative Risk Factors for Early Revisions in Stand-Alone Lateral Lumbar Interbody Fusion
    Rentenberger, Colleen
    Okano, Ichiro
    Salzmann, Stephan N.
    Winter, Fabian
    Plais, Nicolas
    Burkhard, Marco D.
    Shue, Jennifer
    Sama, Andrew A.
    Cammisa, Frank P.
    Girardi, Federico P.
    Hughes, Alexander P.
    WORLD NEUROSURGERY, 2020, 134 : E657 - E663