Biomechanical evaluation of stand-alone lumbar polyether-ether-ketone interbody cage with integrated screws

被引:38
|
作者
Kornblum, Martin B. [1 ]
Turner, Alexander W. L. [2 ]
Cornwall, G. Bryan [2 ]
Zatushevsky, Michael A. [2 ]
Phillips, Frank M. [3 ]
机构
[1] Mendelson Kornblum Orthopaed & Spine Surg, Warren, MI 48093 USA
[2] NuVasive Inc, San Diego, CA 92121 USA
[3] Rush Univ, Med Ctr, Dept Orthoped Surg, Midwest Orthopaed, Chicago, IL 60612 USA
来源
SPINE JOURNAL | 2013年 / 13卷 / 01期
关键词
Biomechanics; Lumbar; ALIF; Interbody fusion; Fixation; PEDICLE SCREWS; VASCULAR INJURY; IN-VITRO; INVITED SUBMISSION; PERIPHERAL-NERVES; SPINAL-FUSION; MARCH; 2005; FIXATION; PLATE; STABILITY;
D O I
10.1016/j.spinee.2012.11.013
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Stand-alone interbody cages with integrated screws potentially provide a biomechanically stable solution for anterior lumbar interbody fusion (ALIF) that alleviates the need for additional exposure for supplemental fixation, thereby reducing the chance of additional complications and morbidity. PURPOSE: To compare the stability of a stand-alone anterior interbody fusion system with integrated fixation screws against traditional supplemental fixation methods and to evaluate the difference between three and four fixation screws in the stand-alone cage. STUDY DESIGN: In vitro cadaveric biomechanical study. METHODS: Eight cadaveric lumbar spines (L2-sacrum) were tested using a flexibility protocol consisting of three cycles to +/- 7.5 Nm in flexion-extension, lateral bending, and axial rotation. The conditions evaluated were intact spine; polyether-ether-ketone cage (zero integrated screws) at L4-L5; cage (zero screws) + bilateral pedicle screws (PS); cage (three screws); cage (four screws); cage (zero screws) + anterior plate; and cage (three screws) + spinous process plate. Motion at the index level was assessed using an optoelectronic system. RESULTS: The cage without integrated screws reduced the motion in flexion-extension and lateral bending (p < .001) compared with that in the intact spine. In axial rotation, mean range of motion (ROM) was 8% greater than in intact spine (p > .962). The addition of three integrated screws reduced ROM significantly compared with the cage without screws in all motion planes (p < .001). A fourth screw had no statistically significant effect on the ROM, although there was a trend toward less motion with four screws compared with three. In flexion-extension, the cage with three integrated screws and the spinous process plate was the most rigid condition. There was no significant difference from the bilateral PS (p = .537); however, this was more rigid than all other conditions (p < .024). The most stable condition in lateral bending and axial rotation was the cage with bilateral PS. In lateral bending, the cage (three or four screws) was not significantly different from the cage with anterior plate or the cage (three screws) with spinous process plate fixation; however, only the latter condition was statistically comparable with bilateral PS. In axial rotation, there were no significant differences between the conditions that included integrated screws or supplemental fixation (p > .081). CONCLUSIONS: Biomechanical testing revealed that the stand-alone cage with integrated screws provides more immediate stability than a cage alone and provides equivalent stability to ALIF constructs with supplemental fixation in lateral bending and axial rotation. Additional flexion-extension rigidity of the anterior cage maybe realized by the addition of a spinous process plate that was found to be as stable as supplemental bilateral PS. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:77 / 84
页数:8
相关论文
共 50 条
  • [21] Biomechanical evaluation of a stand-alone interbody fusion cage based on porous TiO2/glass composites in the human cervical spine
    Korinth, MC
    Moersch, S
    Ragoss, C
    Schopphoff, E
    BIOMEDIZINISCHE TECHNIK, 2003, 48 (12): : 349 - 355
  • [22] The Influence of Endplate Morphology on Cage Subsidence in Patients With Stand-Alone Oblique Lateral Lumbar Interbody Fusion (OLIF)
    Hu, Ziang
    He, Dengwei
    Gao, Jiawei
    Zeng, Zhongyou
    Jiang, Chao
    Ni, Weiyu
    Yik, Jasper H. N.
    Zhao, Xing
    Fan, Shunwu
    GLOBAL SPINE JOURNAL, 2023, 13 (01) : 97 - 103
  • [23] Comments on "The Influence of Endplate Morphology on Cage Subsidence in Patients with Stand-Alone Oblique Lateral Lumbar Interbody Fusion"
    Zhao, Long
    Xie, Tianhang
    GLOBAL SPINE JOURNAL, 2022, 12 (05) : 1031 - 1031
  • [24] Biomechanical comparison of a new stand-alone anterior lumbar interbody fusion cage with established fixation techniques - A three-dimensional finite element analysis
    Chen S.-H.
    Tai C.-L.
    Lin C.-Y.
    Hsieh P.-H.
    Chen W.-P.
    BMC Musculoskeletal Disorders, 9 (1)
  • [25] Biomechanical analysis of stand-alone lumbar interbody cages versus 360° constructs: an in vitro and finite element investigation
    Kiapour, Ali
    Massaad, Elie
    Joukar, Amin
    Hadzipasic, Muhamed
    Shankar, Ganesh M.
    Goel, Vijay K.
    Shin, John H.
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 36 (06) : 928 - 936
  • [26] Stand-alone anterior lumbar interbody fusion for treatment of degenerative spondylolisthesis
    Rao, Prashanth J.
    Ghent, Finn
    Phan, Kevin
    Lee, Keegan
    Reddy, Rajesh
    Mobbs, Ralph J.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2015, 22 (10) : 1619 - 1624
  • [27] A multi-center clinical study of posterior lumbar interbody fusion with the expandable stand-alone cage (Tychea® cage) for degenerative lumbar spinal disorders
    Kim, Jin Wook
    Park, Hyung Chun
    Yoon, Soung Hwan
    Oh, Seong Hoon
    Roh, Sung Woo
    Rim, Dae Cheol
    Kim, Tae Sung
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2007, 42 (04) : 251 - 257
  • [28] Do stand-alone interbody spacers with integrated screws provide adequate segmental stability for multilevel cervical arthrodesis?
    Paik, Haines
    Kang, Daniel G.
    Lehman, Ronald A., Jr.
    Cardoso, Mario J.
    Gaume, Rachel E.
    Ambati, Divya V.
    Dmitriev, Anton E.
    SPINE JOURNAL, 2014, 14 (08): : 1740 - 1747
  • [29] Early bone ingrowth and segmental stability of a trussed titanium cage versus a polyether ether ketone cage in an ovine lumbar interbody fusion model
    Loenen, Arjan C. Y.
    Peters, Marloes J. M.
    Bevers, Raymond T. J.
    Schaffrath, Claus
    van Haver, Els
    Cuijpers, Vincent M. J., I
    Rademakers, Timo
    van Rietbergen, Bert
    Willems, Paul C.
    Arts, Jacobus J.
    SPINE JOURNAL, 2022, 22 (01): : 174 - 182
  • [30] Radiographic and clinical evaluation of cage subsidence after stand-alone lateral interbody fusion Clinical article
    Marchi, Luis
    Abdala, Nitamar
    Oliveira, Leonardo
    Amaral, Rodrigo
    Coutinho, Etevaldo
    Pimenta, Luiz
    JOURNAL OF NEUROSURGERY-SPINE, 2013, 19 (01) : 110 - 118