Auxiliary device for calibration of roller pumps: development and experimental results

被引:1
|
作者
Vieira, F. U., Jr. [1 ,2 ]
Dantas de Medeiros, J., Jr. [3 ]
Antunes, N. [2 ]
Vieira, R. W. [2 ]
Costa, E. T. [1 ,3 ]
机构
[1] State Univ Campinas UNICAMP, Ctr Biomed Engn, Sao Paulo, Brazil
[2] State Univ Campinas UNICAMP, Sch Med Sci, Sao Paulo, Brazil
[3] State Univ Campinas UNICAMP, Sch Elect & Comp Engn, Dept Biomed Engn, Sao Paulo, Brazil
来源
PERFUSION-UK | 2012年 / 27卷 / 06期
关键词
roller pump; hemolysis; calibration device; CARDIOPULMONARY BYPASS; CENTRIFUGAL PUMPS; RETROGRADE FLOW; DYNAMIC METHOD; HEMOLYSIS; SURGERY; BLOOD;
D O I
10.1177/0267659112453077
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Roller pumps are commonly used in surgeries involving extracorporeal circulation and its regulation may influence the hemolysis rate. Objective: To describe an auxiliary device for adjusting roller pumps using the dynamic calibration method and show preliminary results of its application in surgical procedures. Method:The device was tested in the laboratory environment with three disposable pressure transducers normally used in surgeries. In the operation room, tests were carried out with two groups of patients. Free hemoglobin plasma rates were measured,5 minutes after perfusion started and immediately before the passage of the residual volume of the pump. For Group 1 (n = 22), occlusion measurements were carried out using the drop rate method and for Group 2 (n = 18), measurements were carried out using the auxiliary device and 300 mmHg calibration (mean pressure for the dynamic calibration method). Results:The auxiliary calibration device has shown calibration results statistically equal to those obtained with a reference device in the laboratory environment. We have found less variability of hemolysis rates in the operating room, using the auxiliary device and we did not observe any influence of unbalanced rollers in the hemolysis rates.
引用
收藏
页码:512 / 519
页数:8
相关论文
共 50 条
  • [21] Numerical and experimental results on pulsed tubes calibration
    Golovashchenko, S
    SHEET METAL FORMING TECHNOLOGY, 1999, : 117 - 127
  • [22] Baseline calibration of interferometric radiometers: Experimental results
    Corbella, I
    Torres, F
    Camps, A
    Martin-Neira, M
    IGARSS 2005: IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-8, PROCEEDINGS, 2005, : 5547 - 5550
  • [23] A regenerative elastocaloric device: experimental results
    Engelbrecht, Kurt
    Tusek, Jaka
    Eriksen, Dan
    Lei, Tian
    Lee, Chong-Yi
    Tusek, Janez
    Pryds, Nini
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2017, 50 (42)
  • [24] TECHNIQUE AND RESULTS WITH A ROLLER-PUMP LEFT AND RIGHT HEART ASSIST DEVICE
    ROSE, DM
    CONNOLLY, M
    CUNNINGHAM, JN
    SPENCER, FC
    ANNALS OF THORACIC SURGERY, 1989, 47 (01): : 124 - 129
  • [25] Balancing of Turbomolecular Pumps: Modal Balancing Approach and Experimental Results
    Quartarone, Carmelo
    Beqari, Julian
    Detoni, Joaquim Girardello
    Cometti, Flavio
    Emelli, Enrico
    PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON ROTOR DYNAMICS - IFTOMM, VOL. 4, 2019, 63 : 119 - 128
  • [26] EXPERIMENTAL RESULTS FOR THE ROTORDYNAMIC CHARACTERISTICS OF LEAKAGE FLOWS IN CENTRIFUGAL PUMPS
    GUINZBURG, A
    BRENNEN, CE
    ACOSTA, AJ
    CAUGHEY, TK
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (01): : 110 - 115
  • [27] Development of laboratory device to simulate roller-compacted concrete placement
    Marques Filho, Jose
    Paulon, Vladimir A.
    Monteiro, Paulo J. M.
    de Andrade, Walton Pacelli
    Dal Molin, Denise
    ACI MATERIALS JOURNAL, 2008, 105 (02) : 125 - 130
  • [28] Development and accuracy evaluation of a degree of occlusion visualization system for roller pumps used in cardiopulmonary bypass
    Fukaya, Aoi
    Shiraishi, Yasuyuki
    Inoue, Yusuke
    Yamada, Akihiko
    Sahara, Genta
    Kudo, Takemi
    Aizawa, Yasuhiro
    Yambe, Tomoyuki
    JOURNAL OF ARTIFICIAL ORGANS, 2021, 24 (01) : 27 - 35
  • [29] Experimental Study on Learning Effect of Girl College Students in Roller Skating by the Teaching Method of the Rotary Roller Skating Device
    Peng, Wang Da
    Hai, Zhang Xing
    2011 SECOND INTERNATIONAL CONFERENCE ON EDUCATION AND SPORTS EDUCATION (ESE 2011), VOL II, 2011, : 286 - 288
  • [30] Development and accuracy evaluation of a degree of occlusion visualization system for roller pumps used in cardiopulmonary bypass
    Aoi Fukaya
    Yasuyuki Shiraishi
    Yusuke Inoue
    Akihiko Yamada
    Genta Sahara
    Takemi Kudo
    Yasuhiro Aizawa
    Tomoyuki Yambe
    Journal of Artificial Organs, 2021, 24 : 27 - 35