RECONSTRUCTION OF THE ATTENUATED RADON TRANSFORM IN π-SCHEME SHORT-SCAN SPECT

被引:0
|
作者
Shi, Tingting [1 ]
Wang, Jinping [1 ]
机构
[1] Ningbo Univ, Fac Sci, Ningbo 315211, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
nonuniform attenuation; the attenuated Radon transform; Novikov's inversion operator; pi-scheme short-scan; X-RAY TRANSFORMATION; IMAGE-RECONSTRUCTION; INVERSION-FORMULA;
D O I
暂无
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
In this work, the image reconstruction in pi-scheme short-scan single-photon emission computed tomography (SPECT) with nonuniform attenuation is derived in its most general form when pi-scheme short-scan SPECT entails data acquisition over disjoint angular intervals without conjugate views totaling to pi radians. The reconstruction results are based on decomposition of Novikov's inversion operator into three parts bounded in the L-2 sense. The first part involves the measured partial data; the second part is a skew-symmetric operator; the third part is a symmetric and compact contribution. It is showed firstly that the operators involved belong to L(L-2(B)). Furthermore numerical simulations are conducted to demonstrate the effectiveness of the developed method.
引用
收藏
页码:1615 / 1626
页数:12
相关论文
共 50 条
  • [1] RECONSTRUCTION OF THE ATTENUATED RADON TRANSFORM IN π-SCHEME SHORT-SCAN SPECT
    史婷婷
    王金平
    ActaMathematicaScientia, 2013, 33 (06) : 1615 - 1626
  • [2] π-scheme short-scan SPECT and image reconstruction
    Pan, XC
    Kao, CM
    Sidky, EY
    Zou, Y
    Metz, C
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2129 - 2133
  • [3] A Fourier Reconstruction Algorithm in π-Scheme Short-Scan SPECT
    SHI Tingting
    WANG Jinping
    Wuhan University Journal of Natural Sciences, 2013, 18 (02) : 97 - 101
  • [4] π-Scheme short-scan SPECT and image reconstruction with nonuniform attenuation
    Pan, XC
    Kao, CM
    Sidky, EY
    Zou, Y
    Metz, CE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (01) : 87 - 96
  • [5] Reconstruction of myocardial short-scan SPECT images
    Szlávecz, A
    Benyó, B
    Várady, P
    Bükki, T
    INES 2005: 9TH INTERNATIONAL CONFERENCE ON INTELLIGENT ENGINEERING SYSTEMS, 2005, : 37 - 41
  • [6] A wavelet-based SPECT reconstruction algorithm for nonuniformly attenuated Radon transform
    Wen, Junhai
    Kong, Lingkai
    MEDICAL PHYSICS, 2010, 37 (09) : 4762 - 4767
  • [7] Avoiding the backprojection weight in short-scan CT reconstruction
    Dennerlein, Frank
    Noo, Frederic
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2507 - +
  • [8] Investigation of Image Quality on Short-Scan CBCT Reconstruction
    Thanasupsombat, Chalinee
    Thongvigitmanee, Saowapak S.
    Aootaphao, Sorapong
    Thajchayapong, Pairash
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [9] Investigation of an Efficient Short-scan C-arm Reconstruction Method with Radon-based Redundancy Handling
    Dennerlein, Frank
    Kunze, Holger
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [10] Local cone-beam SPECT reconstruction algorithm for non-uniformly attenuated radon transform
    Chen, Yunbin
    Wen, Junhai
    Wang, Li
    Liang, Zhengrong
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2010, 31 (04): : 845 - 850