π-Scheme short-scan SPECT and image reconstruction with nonuniform attenuation

被引:6
|
作者
Pan, XC [1 ]
Kao, CM [1 ]
Sidky, EY [1 ]
Zou, Y [1 ]
Metz, CE [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
attenuation correction; consistency conditions; short-scan; SPECT;
D O I
10.1109/TNS.2002.807917
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Because the effects of physical factors such as photon attenuation and spatial resolution are distance-dependent in single-photon emission computed tomography (SPECT),,it is generally considered that accurate image reconstruction requires knowledge of the data function over 2pi. In SPECT with only uniform attenuation, Noo and Wagner recently showed that an accurate image can be reconstructed from knowledge of the data function over the interval [0, pi). In this work, we consider image reconstruction in pi-scheme SPECT with nonuniform attenuation. In its most general form, pi-scheme SPECT entails data acquisition over disjoint angular intervals without conjugate views, totaling to pi radians. We develop an heuristic perspective for observing that the data function in full-scan SPECT contains redundant information and that the data function in pi-scheme SPECT contains complete information necessary for accurate image reconstruction. We conduct simulation studies in which the expectation maximization algorithm is used for image reconstruction from the data acquired in pi-scheme SPECT with nonuniform attenuation. The results in these simulation studies seem to corroborate hypothesis that accurate images can be reconstructed from pi-scheme data. pi-scheme SPECT allows data acquisition over different combinations of disjoint angular intervals, thereby providing-a flexibility in choosing projection views at which the emitted gamma-rays may undergo the least attenuation and blurring. It should be stressed, however, that the proposed perspective on. redundant information is intended only to heuristically reveal the data redundancy in SPECT with nonuniform attenuation and that it has not been demonstrated mathematically to guarantee the stability and exactness of image reconstruction from the pi-scheme data.
引用
收藏
页码:87 / 96
页数:10
相关论文
共 50 条
  • [1] π-scheme short-scan SPECT and image reconstruction
    Pan, XC
    Kao, CM
    Sidky, EY
    Zou, Y
    Metz, C
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2129 - 2133
  • [2] A Fourier Reconstruction Algorithm in π-Scheme Short-Scan SPECT
    SHI Tingting
    WANG Jinping
    Wuhan University Journal of Natural Sciences, 2013, 18 (02) : 97 - 101
  • [3] RECONSTRUCTION OF THE ATTENUATED RADON TRANSFORM IN π-SCHEME SHORT-SCAN SPECT
    史婷婷
    王金平
    ActaMathematicaScientia, 2013, 33 (06) : 1615 - 1626
  • [4] RECONSTRUCTION OF THE ATTENUATED RADON TRANSFORM IN π-SCHEME SHORT-SCAN SPECT
    Shi, Tingting
    Wang, Jinping
    ACTA MATHEMATICA SCIENTIA, 2013, 33 (06) : 1615 - 1626
  • [5] Reconstruction of myocardial short-scan SPECT images
    Szlávecz, A
    Benyó, B
    Várady, P
    Bükki, T
    INES 2005: 9TH INTERNATIONAL CONFERENCE ON INTELLIGENT ENGINEERING SYSTEMS, 2005, : 37 - 41
  • [6] Investigation of Image Quality on Short-Scan CBCT Reconstruction
    Thanasupsombat, Chalinee
    Thongvigitmanee, Saowapak S.
    Aootaphao, Sorapong
    Thajchayapong, Pairash
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [7] Image reconstruction from cone-beam data on a circular short-scan
    Noo, F
    Heuscher, DJ
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 50 - 59
  • [8] Avoiding the backprojection weight in short-scan CT reconstruction
    Dennerlein, Frank
    Noo, Frederic
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2507 - +
  • [9] ITERATIVE RECONSTRUCTION METHODS FOR NONUNIFORM ATTENUATION DISTRIBUTION IN SPECT
    MAZE, A
    LECLOIREC, J
    COLLOREC, R
    BIZAIS, Y
    BRIANDET, P
    BOURGUET, P
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (07) : 1204 - 1209
  • [10] Short-scan FBP Reconstruction With Filter-based Redundancy Handling
    Dennerlein, Frank
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4211 - 4213