RECONSTRUCTION OF THE ATTENUATED RADON TRANSFORM IN π-SCHEME SHORT-SCAN SPECT

被引:0
|
作者
Shi, Tingting [1 ]
Wang, Jinping [1 ]
机构
[1] Ningbo Univ, Fac Sci, Ningbo 315211, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
nonuniform attenuation; the attenuated Radon transform; Novikov's inversion operator; pi-scheme short-scan; X-RAY TRANSFORMATION; IMAGE-RECONSTRUCTION; INVERSION-FORMULA;
D O I
暂无
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
In this work, the image reconstruction in pi-scheme short-scan single-photon emission computed tomography (SPECT) with nonuniform attenuation is derived in its most general form when pi-scheme short-scan SPECT entails data acquisition over disjoint angular intervals without conjugate views totaling to pi radians. The reconstruction results are based on decomposition of Novikov's inversion operator into three parts bounded in the L-2 sense. The first part involves the measured partial data; the second part is a skew-symmetric operator; the third part is a symmetric and compact contribution. It is showed firstly that the operators involved belong to L(L-2(B)). Furthermore numerical simulations are conducted to demonstrate the effectiveness of the developed method.
引用
收藏
页码:1615 / 1626
页数:12
相关论文
共 50 条
  • [21] An SVD reconstruction algorithm using a natural pixel representation of the attenuated radon transform
    Gullberg, GT
    Hsieh, YL
    Zeng, GL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (01) : 295 - 303
  • [22] ON THE INJECTIVITY OF THE ATTENUATED RADON-TRANSFORM
    HERTLE, A
    PROCEEDINGS OF THE AMERICAN MATHEMATICAL SOCIETY, 1984, 92 (02) : 201 - 205
  • [23] The attenuated Radon transform with complex coefficients
    You, Jiangsheng
    INVERSE PROBLEMS, 2007, 23 (05) : 1963 - 1971
  • [24] ECG gated circular cone-beam multi-cycle short-scan reconstruction algorithm
    van Stevendaal, Udo
    Koken, Peter
    Begemann, Philipp G. C.
    Koester, Ralf
    Adam, Gerhard
    Grass, Michael
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [25] Image and feature reconstruction for the attenuated Radon transform via circular harmonic decomposition of the kernel
    Rigaud, G.
    Lakhal, A.
    INVERSE PROBLEMS, 2015, 31 (02)
  • [26] Exact and efficient cone-beam reconstruction algorithm for a short-scan circle combined with various lines
    Dennerlein, F
    Katsevich, A
    Lauritsch, G
    Hornegger, J
    MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 : 388 - 399
  • [27] Motion Compensation in Short-scan CBCT Reconstructions for Dental Applications
    Ali, Abdul Salam Rasmi Asraf
    Sarti, Cristina
    Landi, Claudio
    Fusiello, Andrea
    MEDICAL IMAGING 2024: IMAGE PROCESSING, 2024, 12926
  • [28] On the attenuated Radon transform with full and partial measurements
    Bal, G
    INVERSE PROBLEMS, 2004, 20 (02) : 399 - 418
  • [29] The Inversion of the Attenuated Radon Transform and Medical Imaging
    UNIFIED APPROACH TO BOUNDARY VALUE PROBLEMS, 2008, 78 : 103 - 111
  • [30] A short-scan reconstruction for cone-beam CT Using shift-invariant FBP and equal weighting
    Zhu, Lei
    Yoon, Sungwon
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2007, 34 (11) : 4422 - 4438