Separation of nickel and chromium on a porous glass-packed column using nitric acid and citric acid as eluent

被引:2
|
作者
Fujiyoshi, I [1 ]
机构
[1] Kagoshima Univ, Dept Appl Chem & Chem Engn, Kagoshima 8900065, Japan
关键词
nickel; chromium; nitric acid; citric acid; porous glass; separation;
D O I
10.1252/kakoronbunshu.31.249
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Experiments to separate nickel and chromium were carried out at 298 K on a porous glass packed-column using nitric acid and citric acid as an eluent. When nitric acid was used as an eluent, both metals were perfectly recovered in the concentration range of 0.02-0.05 mol/dm(3), and they were isocratically and perfectly separated at 0.02 mol/dm(3). When 0.1 mol/dm(3) citric acid was used as an eluent, both metals were perfectly separated in the range of pH 1.7-2.2, and isocratic elution was especially possible at pH 1.7 and at pH 2.2. It was considered that the perfect separation of both metals could be performed in this pH region, since generation of CrOH (2+) ion, which was eluted simultaneously with Ni2+ ion, was suppressed. It was found that separation performance was raised, since the retention volume of chromium was increased and that of nickel was hardly changed with decrease in the amount of both metals loaded.
引用
收藏
页码:249 / 252
页数:4
相关论文
共 50 条
  • [41] Production of bioactive glass-derived scaffolds using citric acid porogen
    Izadi, Samaneh
    Hesaraki, Saeed
    Hafezi-Ardakani, Masoud
    INTERNATIONAL JOURNAL OF MATERIALS RESEARCH, 2015, 106 (03) : 301 - 306
  • [42] EFFECTS OF COLD WORK AND GALVANIC COUPLING ON CORROSION OF CHROMIUM-NICKEL STAINLESS STEELS IN NITRIC ACID SOLUTIONS DURING NITRIC ACID PRODUCTION.
    Kostic, S.Z.
    British Corrosion Journal, 1987, 22 (01): : 53 - 55
  • [43] CORROSION-RESISTANCE OF NICKEL ALLOYED WITH CHROMIUM AND SILICON TO RED FUMING NITRIC-ACID
    GURVICH, LY
    ZHIRNOV, AD
    PROTECTION OF METALS, 1995, 31 (03): : 231 - 235
  • [44] Development of an HPLC System Using a Phase-Separation Multiphase Flow as an Eluent- Effect of Pore Size in Column-Packed Particles on the Novel Separation Mode -
    Ishikawa, Daiki
    Obata, Yuki
    Sakamaki, Hiroshi
    Iharada, Takeshi
    Tsukagoshi, Kazuhiko
    BUNSEKI KAGAKU, 2024, 73 (09) : 505 - 514
  • [45] SEPARATION OF AMERICIUM AND EUROPIUM FROM SOLUTIONS OF NITRIC AND PERCHLORIC ACID USING DIPICOLINIC ACID DIAMIDES
    Alyapyshev, M. Yu.
    Babain, V. A.
    Smirnov, I. V.
    Shadrin, A. Yu.
    CZECHOSLOVAK JOURNAL OF PHYSICS, 2006, 56 : D469 - D475
  • [46] LC Separation of Fatty Acid Ceramides Using a Two Column System
    Budvytiene, Monika
    Babenko, Nataliya
    Liesiene, Jolanta
    CHROMATOGRAPHIA, 2009, 69 (11-12) : 1473 - 1475
  • [47] LC Separation of Fatty Acid Ceramides Using a Two Column System
    Monika Budvytiene
    Nataliya Babenko
    Jolanta Liesiene
    Chromatographia, 2009, 69 : 1473 - 1475
  • [48] Column Separation of Am(III) and Eu(III) by α-Zirconium Phosphate Ion Exchanger in Nitric Acid
    Wiikinkoski, Elmo W.
    Rautsola, Iiro
    Xu, Junhua
    Koivula, Risto
    CHEMENGINEERING, 2020, 4 (01) : 1 - 13
  • [49] Serial separation of cations and anions by ion chromatography using the peak parking technique and sulfosalicylic acid as the eluent
    Muhammad Amin
    Lee Wah Lim
    Toyohide Takeuchi
    Analytical and Bioanalytical Chemistry, 2006, 384 : 839 - 843
  • [50] Micro Pre-concentration and Separation of Metal Ions Using Microchip Column Packed with Magnetic Particles Immobilized by Aminobenzyl Ethylenediaminetetraacetic Acid
    Kim, Y. H.
    Kim, G. Y.
    Lim, H. B.
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2010, 31 (04): : 905 - 909