Corneal Power Measurement Obtained by Fourier-Domain Optical Coherence Tomography: Repeatability, Reproducibility, and Comparison With Scheimpflug and Automated Keratometry Measurements

被引:22
|
作者
Wang, Qinmei [1 ,2 ,3 ]
Hua, Yanjun [1 ,2 ,3 ]
Savini, Giacomo [4 ]
Chen, Hao [1 ,2 ,3 ]
Bao, Fangjun [1 ,2 ]
Lin, Shishi [1 ,2 ]
Lu, Weicong [1 ,2 ]
Huang, Jinhai [1 ,2 ,3 ]
机构
[1] Wenzhou Med Univ, Sch Ophthalmol & Optometry, Wenzhou 325027, Zhejiang, Peoples R China
[2] Wenzhou Med Univ, Hosp Eye, Wenzhou 325027, Zhejiang, Peoples R China
[3] Minist Hlth PR China, Key Lab Vis Sci, Wenzhou, Zhejiang, Peoples R China
[4] GB Bietti Fdn IRCCS, Rome, Italy
关键词
corneal power; Scheimpflug; optical coherence tomography; precision; agreement; INTRAOCULAR-LENS POWER; LASER REFRACTIVE SURGERY; STATISTICAL-METHODS; PENTACAM; AGREEMENT; CAMERA; SYSTEM;
D O I
10.1097/ICO.0000000000000564
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To assess the repeatability and reproducibility of corneal power values obtained by a Fourier-domain optical coherence tomography (FD-OCT) system (RTVue) and to compare them with the values obtained by a Scheimpflug camera system (Pentacam HR) and by automated keratometry (IOL Master).Methods:Thirty-two eyes from 32 healthy subjects were included in this prospective study. Two experienced observers measured each eye 3 consecutive times with the Pentacam, IOLMaster, and RTVue centered on either the pupil or corneal vertex. The conventional keratometry equivalent (CKE) and anterior (K-a), posterior (K-p), and net (K-n) corneal power values were determined.Results:The corneal power values obtained by the RTVue showed high repeatability (all intraclass correlation coefficient >0.96) and reproducibility (coefficient of variation <1.0%). Pupil-centered FD-OCT performed slightly better than corneal vertex-centered FD-OCT. Mean corneal values had higher reproducibly than any of the individual values. CKE, K-a, K-p, and K-n obtained by FD-OCT were 0.62 to 0.68 diopters (D), 0.70 to 0.76 D, 0.11 to 0.13 D, and 0.93 to 0.94 D higher than those obtained by the Pentacam HR, respectively. CKE and K-a obtained with the RTVue were also 0.60 to 0.74 D higher than those obtained with the IOLMaster, respectively.Conclusions:The corneal power measurements obtained by the RTVue FD-OCT system showed high repeatability and reproducibility. Measurements obtained by FD-OCT with pupil centration were more reproducible than those obtained by FD-OCT with corneal vertex centration. We recommend that pupil-centered FD-OCT be used in clinical applications. Neither RTVue versus Pentacam HR nor RTVue versus IOLMaster can be used interchangeably.
引用
收藏
页码:1266 / 1271
页数:6
相关论文
共 50 条
  • [41] Corneal Epithelial Thickness Mapping by Fourier-Domain Optical Coherence Tomography in Normal and Keratoconic Eyes
    Li, Yan
    Tan, Ou
    Brass, Robert
    Weiss, Jack L.
    Huang, David
    OPHTHALMOLOGY, 2012, 119 (12) : 2425 - 2433
  • [42] Corneal Epithelial Thickness Mapping in Normal and Keratoconic Eyes With Fourier-Domain Optical Coherence Tomography
    Li, Y.
    Tan, O.
    Huang, D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [43] Comparison of ultrasonic pachymetry and Fourier-domain optical coherence tomography for measurement of corneal thickness in dogs with and without corneal disease (vol 242, pg 59, 2018)
    Hoehn, A. L.
    Thomasy, S. M.
    Kass, P. H.
    Horikawa, T.
    Samuel, M.
    Shull, O. R.
    Stewart, K. A.
    Murphy, C. J.
    VETERINARY JOURNAL, 2020, 262
  • [44] Time-domain interpolation for Fourier-domain optical coherence tomography
    Zhang, Yudong
    Li, Xiqi
    Wei, Ling
    Wang, Kai
    Ding, Zhihua
    Shi, Guohua
    OPTICS LETTERS, 2009, 34 (12) : 1849 - 1851
  • [45] Application of Keratograph and Fourier-Domain Optical Coherence Tomography in Measurements of Tear Meniscus Height
    Chen, Minjie
    Wei, Anji
    Xu, Jianjiang
    Zhou, Xingtao
    Hong, Jiaxu
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (05)
  • [46] Normal and Keratoconic Corneal Epithelial Thickness Mapping using Fourier-Domain Optical Coherence Tomography
    Li, Yan
    Tan, Ou
    Huang, David
    MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965
  • [47] Characterization of coated optical fibers by Fourier-domain optical coherence tomography
    Jasapara, J
    Wielandy, S
    OPTICS LETTERS, 2005, 30 (09) : 1018 - 1020
  • [48] Repeatability and Interobserver Reproducibility of a Swept-Source Optical Coherence Tomography for Measurements of Anterior, Posterior, and Total Corneal Power
    Lei, Chak Seng
    Lin, Xuanqiao
    Ning, Rui
    Yu, Jinjin
    Huang, Xiaomin
    Li, Kexin
    Wang, Yiran
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Huang, Jinhai
    OPHTHALMOLOGY AND THERAPY, 2023, 12 (06) : 3263 - 3279
  • [49] Repeatability and Interobserver Reproducibility of a Swept-Source Optical Coherence Tomography for Measurements of Anterior, Posterior, and Total Corneal Power
    Chak Seng Lei
    Xuanqiao Lin
    Rui Ning
    Jinjin Yu
    Xiaomin Huang
    Kexin Li
    Yiran Wang
    Giacomo Savini
    Domenico Schiano-Lomoriello
    Xingtao Zhou
    Jinhai Huang
    Ophthalmology and Therapy, 2023, 12 : 3263 - 3279
  • [50] Repeatability, reproducibility, and agreement of corneal power measurements obtained with a new corneal topographer
    Mao, Xinjie
    Savini, Giacomo
    Zhuo, Zuopao
    Feng, Yifan
    Zhang, Jian
    Wang, Qinmei
    Chen, Hao
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (10): : 1561 - 1569