Two-Dimensional Color Doppler Echocardiography for Left Ventricular Stroke Volume Assessment: A Comparison Study with Three-Dimensional Echocardiography

被引:9
|
作者
Da Silva, Cristina [1 ]
Pedro, Fatima [1 ]
Deister, Lizandra [1 ]
Sahlen, Anders [2 ]
Manouras, Aristomenis [2 ]
Shahgaldi, Kambiz [3 ]
机构
[1] Karolinska Univ Hosp, Dept Clin Physiol, Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Cardiol & Clin Physiol, Stockholm, Sweden
[3] Karolinska Univ Hosp, Dept Cardiol, Stockholm, Sweden
关键词
left ventricular outflow tract; left ventricular stroke volume; color Doppler; three-dimensional echocardiography; AORTIC-VALVE AREA; OUTFLOW TRACT; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; EJECTION FRACTION; BIPLANE MODE; STENOSIS; ACCURACY; QUANTIFICATION; RECOMMENDATIONS;
D O I
10.1111/j.1540-8175.2012.01695.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: Whether measurement of left ventricular outflow tract diameter (LVOTd) using color Doppler (CD) in order to more accurately define LVOTd is more accurate for determination of stroke volume (SV) than gray scale and compare it with direct measurement of LVOT area (a) using three-dimensional echocardiography (3DE) for SV determination. Methods and Results: Twenty-one volunteers were examined. LVOTa was calculated by two-dimensional echocardiography (2DE) using the following formula: px (d/2)2, d = LVOT diameter by gray scale and CD, respectively. Planimetry of LVOTa was performed in parasternal long axis using 3DE. Eccentricity Index was calculated using the lateral and anterior-posterior LVOTd. SV was obtained by four different methods: (1) 2D gray scale, (2) 2D color, (3) LVOTa x LVOT velocity time integral, and (4) SV by Simpson's biplane method. Gray scale LVOTd was significantly smaller compared to LVOTd obtained with CD (P < 0.05). Significant differences occurred between LVOTa gray scale and CD (3.29 +/- 0.74 cm2 vs 3.67 +/- 0.70 cm2, P < 0.05) and between LVOTa calculated by gray scale in comparison to 3DE planimetry; (3.29 +/- 0.74 cm2 vs 3.61 +/- 0.89 cm2, P = 0.011). Half of the subjects had at least 17% difference between the lateral and anterior-posterior LVOTd. There were significant differences between SV by 2D gray scale and 2D CD (82.8 +/- 17.1 mL vs 92.4 +/- 16.8 mL, P < 0.05) and between 2D gray scale and 3DE planimetry (82.8 +/- 17.1 mL vs 90.7 +/- 19.8 mL, P = 0.025). Conclusion: Our study demonstrates LVOT being frequently elliptical. SV and LVOTa were found to be similar when comparing 2DE CD and 3DE planimetry and showed higher values in comparison to 2DE gray scale, which suggests 2DE CD to be an alternative approach for SV assessment.
引用
收藏
页码:766 / 772
页数:7
相关论文
共 50 条
  • [31] Accuracy of Automated Three-dimensional Echocardiography in Evaluating Left Ventricular Volume and Ejection Fraction in Patients With Hypertrophic Cardiomyopathy: A Comparative Study With Current Clinical Two-dimensional Echocardiography
    Zhang, Li
    Wang, Yushan
    Zhang, Li
    Xie, Mingxing
    Wu, Chun
    Li, Yuman
    Li, Meng
    Sun, Wei
    Wang, Shuyuan
    CIRCULATION, 2019, 140
  • [32] Left Ventricular Volume with Three-Dimensional Echocardiography: All Vendors the Same?
    Harrelson, Allan
    Shizukuda, Yukitaka
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (05): : 622 - 622
  • [33] Three-dimensional echocardiography of normal and pathologic mitral valve: A comparison with two-dimensional transesophageal echocardiography
    Salustri, A
    Becker, AE
    vanHerwerden, L
    Vletter, WB
    TenCate, FJ
    Roelandt, JRTC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (06) : 1502 - 1510
  • [34] Accuracy of gated SPECT thallium left ventricular volumes and ejection fractions: Comparison with three-dimensional and two-dimensional echocardiography
    Akinboboye, OO
    Friedlander, JP
    Idris, O
    Coffin, LEK
    Keller, AM
    King, DL
    Bergmann, SR
    CIRCULATION, 1998, 98 (17) : 588 - 588
  • [35] Intraoperative Three-Dimensional Versus Two-Dimensional Echocardiography for Left Ventricular Assessment (vol 118, pg 711, 2014)
    Meris, A.
    Santambrogio, L.
    Casso, G.
    Mauri, R.
    Engeler, A.
    Cassina, T.
    ANESTHESIA AND ANALGESIA, 2014, 118 (06): : 1394 - 1394
  • [36] Combination of pulsed-wave Doppler and real-time three-dimensional color Doppler echocardiography for quantifying the stroke volume in the left ventricular outflow tract
    Tsujino, H
    Jones, M
    Qin, JX
    Sitges, M
    Cardon, LA
    Morehead, AL
    Zetts, AD
    Bauer, F
    Kim, YJ
    Hang, XY
    Greenberg, N
    Thomas, JD
    Shiota, T
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (11): : 1441 - 1446
  • [37] Determination of Fetal Left Ventricular Volume Based on Two-Dimensional Echocardiography
    Yu, Li
    Guo, Yi
    Wang, Yuanyuan
    Yu, Jinhua
    Chen, Ping
    JOURNAL OF HEALTHCARE ENGINEERING, 2017, 2017
  • [38] Two-dimensional speckle tracking echocardiography and three-dimensional echocardiography characterization of left atrial giant myxoma
    Cacciapuoti, Fulvio
    Magro, Valerio Massimo
    Caturano, Michele
    Cacciapuoti, Federico
    JOURNAL OF CARDIOVASCULAR ECHOGRAPHY, 2016, 26 (02) : 68 - 70
  • [39] Comparison of transesophageal echocardiography and two-dimensional echocardiography in stroke evaluation
    Alkhersam, HH
    Cheema, ZF
    ANNALS OF NEUROLOGY, 1998, 44 (03) : 447 - 448
  • [40] Two-dimensional strain echocardiography-derived left ventricular ejection fraction, volumes, and global systolic dyssynchrony index: Comparison with three-dimensional echocardiography
    Vaidya, Gaurang Nandkishor
    Salgado, Benjamin C.
    Badar, Faraz
    John, Anub
    Stoddard, Marcus F.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (06): : 1054 - 1065