Biodegradable Zwitterionic Polymer Coatings for Magnesium Alloy Stents

被引:33
|
作者
Ye, Sang-Ho [1 ,2 ]
Chen, Yingqi [1 ]
Mao, Zhongwei [1 ]
Gu, Xinzhu [1 ]
Shankarraman, Venkat [1 ]
Hong, Yi [4 ]
Shanov, Vesselin [5 ,6 ]
Wagner, William R. [1 ,2 ,3 ,4 ]
机构
[1] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA 15219 USA
[2] Univ Pittsburgh, Dept Surg, Pittsburgh, PA 15219 USA
[3] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15219 USA
[4] Univ Pittsburgh, Dept Chem & Petr Engn, Pittsburgh, PA 15219 USA
[5] Univ Texas Arlington, Dept Bioengn, Arlington, TX 76019 USA
[6] Univ Cincinnati, Coll Engn & Appl Sci, Cincinnati, OH 45221 USA
基金
美国国家科学基金会;
关键词
SIROLIMUS-ELUTING STENTS; BLOOD COMPATIBILITY; BIORESORBABLE SCAFFOLD; CORROSION-RESISTANCE; THIN; HEMOCOMPATIBILITY; MULTICENTER;
D O I
10.1021/acs.langmuir.8b01623
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Degradable metallic stents, most commonly composed of Mg-based alloys, are of interest as an alternative to traditional metallic stents for application in cardiac and peripheral vasculature. Two major design challenges with such stents are control of the corrosion rate and acute presentation of a nonthrombogenic surface to passing blood. In this study, several types of sulfobetaine (SB)-bearing biodegradable polyurethanes were developed and assessed as physical, chemical, and combination-type coatings for a model degradable Mg alloy, AZ31. For physical coatings, poly(ester sulfobetaine)urethane ureas, PESBUUs were synthesized using variable monomers that allowed the incorporation of a varying extent of carboxyl groups. Introduction of the carboxyl groups was associated with faster polymer degradation time. Simple physical coating of PESBUUs reduced macro- and microscopic thrombogenic deposition together with good stability of the coating attachment compared to a control coating of polylactic-co-glycolic acid. For PESBUUs incorporating carboxyl groups (PESBUUs-COOH), these groups could be converted to siloxane groups (PESBUUs-Si), thus creating polymers that could be surface reacted with the oxidized or phytic acid treated AZ31 surface. Chemical (silanization) attachment of these polymers reduced underlying alloy corrosion rates, but following the salination reaction with physical coating most reduced corrosion rates and protected the surface better from the consequences of oxidation occurring under the coating, such as blistering. The application of a multilayered coating approach using a sulfobetaine-based biodegradable elastomer thus offers options for degradable metallic stent design where thromboresistance is desired in combination with a means to control both polymeric coating degradation rates and underlying alloy corrosion rates.
引用
收藏
页码:1421 / 1429
页数:9
相关论文
共 50 条
  • [41] Advances in coatings on biodegradable magnesium alloys
    Yin, Zheng-Zheng
    Qi, Wei-Chen
    Zeng, Rong-Chang
    Chen, Xiao-Bo
    Gu, Chang-Dong
    Guan, Shao-Kang
    Zheng, Yu-Feng
    JOURNAL OF MAGNESIUM AND ALLOYS, 2020, 8 (01) : 42 - 65
  • [42] Biocompatibility and corrosion resistance of drug coatings with different polymers for magnesium alloy cardiovascular stents
    Liu, Kuei-Ping
    Cheng, An-Yu
    You, Jhu-Lin
    Chang, Yen-Hao
    Tseng, Chun Chieh
    Ger, Ming-Der
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2025, 245
  • [43] Comparative study of different polymeric coatings for the next-generation magnesium-based biodegradable stents
    Lakalayeh, Gholamreza Ahmadi
    Rahvar, Mostafa
    Haririan, Esmaeil
    Karimi, Roya
    Ghanbari, Hossein
    ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2018, 46 (07) : 1380 - 1389
  • [44] Biodegradable Magnesium Alloy-Based Composites: Properties, Processing, and Surface Coatings—A Review
    Vighnesh Raj
    S. Sabarinath
    Vaira Vignesh Ramalingam
    Transactions of the Indian Institute of Metals, 2023, 76 : 2435 - 2443
  • [45] Biodegradable phytic acid conversion coatings on magnesium alloy for temporary orthopedic implant: A review
    Xu, Yingchao
    Guo, Yunting
    Li, Guangyu
    Lian, Jianshe
    PROGRESS IN ORGANIC COATINGS, 2022, 169
  • [46] Biodegradable phytic acid conversion coatings on magnesium alloy for temporary orthopedic implant: A review
    Xu, Yingchao
    Guo, Yunting
    Li, Guangyu
    Lian, Jianshe
    PROGRESS IN ORGANIC COATINGS, 2022, 169
  • [47] Biodegradable polymer coatings on Ti6Al7Nb alloy
    Szewczenko, Janusz
    Kajzer, Wojciech
    Kajzer, Anita
    Basiaga, Marcin
    Kaczmarek, Marcin
    Antonowicz, Magdalena
    Nowinska, Katarzyna
    Jaworska, Joanna
    Jelonek, Katarzyna
    Kasperczyk, Janusz
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2019, 21 (04) : 83 - 92
  • [48] Biodegradable magnesium coronary stents: material, design and fabrication
    Demir, Ali Goekhan
    Previtali, Barbara
    Ge, Qiang
    Vedani, Maurizio
    Wu, Wei
    Migliavacca, Francesco
    Petrini, Lorenza
    Biffi, Carlo Alberto
    Bestetti, Massimiliano
    INTERNATIONAL JOURNAL OF COMPUTER INTEGRATED MANUFACTURING, 2014, 27 (10) : 936 - 945
  • [49] Development of Magnesium Alloy as Biodegradable Material
    Wang, Yu
    Chen, Yong
    Duan, Xiaolian
    Zhang, Huatang
    PROCEEDINGS OF THE 2013 INTERNATIONAL CONFERENCE ON MATERIAL SCIENCE AND ENVIRONMENTAL ENGINEERING (MSEE 2013), 2013, : 338 - 341
  • [50] Biodegradable, elastomeric coatings with controlled anti-proliferative agent release for magnesium-based cardiovascular stents
    Gu, Xinzhu
    Mao, Zhongwei
    Ye, Sang-Ho
    Koo, Youngmi
    Yun, Yeoheung
    Tiasha, Tarannum R.
    Shanov, Vesselin
    Wagner, William R.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2016, 144 : 170 - 179