Biodegradable Zwitterionic Polymer Coatings for Magnesium Alloy Stents

被引:33
|
作者
Ye, Sang-Ho [1 ,2 ]
Chen, Yingqi [1 ]
Mao, Zhongwei [1 ]
Gu, Xinzhu [1 ]
Shankarraman, Venkat [1 ]
Hong, Yi [4 ]
Shanov, Vesselin [5 ,6 ]
Wagner, William R. [1 ,2 ,3 ,4 ]
机构
[1] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA 15219 USA
[2] Univ Pittsburgh, Dept Surg, Pittsburgh, PA 15219 USA
[3] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15219 USA
[4] Univ Pittsburgh, Dept Chem & Petr Engn, Pittsburgh, PA 15219 USA
[5] Univ Texas Arlington, Dept Bioengn, Arlington, TX 76019 USA
[6] Univ Cincinnati, Coll Engn & Appl Sci, Cincinnati, OH 45221 USA
基金
美国国家科学基金会;
关键词
SIROLIMUS-ELUTING STENTS; BLOOD COMPATIBILITY; BIORESORBABLE SCAFFOLD; CORROSION-RESISTANCE; THIN; HEMOCOMPATIBILITY; MULTICENTER;
D O I
10.1021/acs.langmuir.8b01623
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Degradable metallic stents, most commonly composed of Mg-based alloys, are of interest as an alternative to traditional metallic stents for application in cardiac and peripheral vasculature. Two major design challenges with such stents are control of the corrosion rate and acute presentation of a nonthrombogenic surface to passing blood. In this study, several types of sulfobetaine (SB)-bearing biodegradable polyurethanes were developed and assessed as physical, chemical, and combination-type coatings for a model degradable Mg alloy, AZ31. For physical coatings, poly(ester sulfobetaine)urethane ureas, PESBUUs were synthesized using variable monomers that allowed the incorporation of a varying extent of carboxyl groups. Introduction of the carboxyl groups was associated with faster polymer degradation time. Simple physical coating of PESBUUs reduced macro- and microscopic thrombogenic deposition together with good stability of the coating attachment compared to a control coating of polylactic-co-glycolic acid. For PESBUUs incorporating carboxyl groups (PESBUUs-COOH), these groups could be converted to siloxane groups (PESBUUs-Si), thus creating polymers that could be surface reacted with the oxidized or phytic acid treated AZ31 surface. Chemical (silanization) attachment of these polymers reduced underlying alloy corrosion rates, but following the salination reaction with physical coating most reduced corrosion rates and protected the surface better from the consequences of oxidation occurring under the coating, such as blistering. The application of a multilayered coating approach using a sulfobetaine-based biodegradable elastomer thus offers options for degradable metallic stent design where thromboresistance is desired in combination with a means to control both polymeric coating degradation rates and underlying alloy corrosion rates.
引用
收藏
页码:1421 / 1429
页数:9
相关论文
共 50 条
  • [31] Preparation and Performance of Plasma/Polymer Composite Coatings on Magnesium Alloy
    Bakhsheshi-Rad, H. R.
    Hamzah, E.
    Bagheriyan, S.
    Daroonparvar, M.
    Kasiri-Asgarani, M.
    Shah, A. M.
    Medraj, M.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2016, 25 (09) : 3948 - 3959
  • [32] Preparation and Performance of Plasma/Polymer Composite Coatings on Magnesium Alloy
    H. R. Bakhsheshi-Rad
    E. Hamzah
    S. Bagheriyan
    M. Daroonparvar
    M. Kasiri-Asgarani
    A. M. Shah
    M. Medraj
    Journal of Materials Engineering and Performance, 2016, 25 : 3948 - 3959
  • [33] Aerosol deposition of hydroxyapatite-chitosan composite coatings on biodegradable magnesium alloy
    Hahn, Byung-Dong
    Park, Dong-Soo
    Choi, Jong-Jin
    Ryu, Jungho
    Yoon, Woon-Ha
    Choi, Joon-Hwan
    Kim, Hyoun-Ee
    Kim, Seong-Gon
    SURFACE & COATINGS TECHNOLOGY, 2011, 205 (8-9): : 3112 - 3118
  • [34] Biodegradable-polymer stents versus durable-polymer stents reply
    Juni, Peter
    Heg, Dik
    Windecker, Stephan
    Pilgrim, Thomas
    LANCET, 2019, 393 (10184): : 1933 - 1933
  • [35] Influence of biodegradable polymer coatings on corrosion, cytocompatibility and cell functionality of Mg-2.0Zn-0.98Mn magnesium alloy
    Witecka, Agnieszka
    Yamamoto, Akiko
    Idaszek, Joanna
    Chlanda, Adrian
    Swieszkowski, Wojciech
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2016, 144 : 284 - 292
  • [36] Simulation study on uneven expansion behaviour of biodegradable magnesium alloy stents by finite element analysis
    Li, J.
    Mao, Z.
    Zheng, F.
    Tan, L.
    Yang, K.
    MATERIALS SCIENCE AND TECHNOLOGY, 2014, 30 (05) : 527 - 533
  • [37] Long, thin-wall capillary tube fabrication technology for biodegradable magnesium alloy stents
    Hanada, Kotaro
    Matsuzaki, Kunio
    AIST Today (International Edition), 2014, (53):
  • [38] Visibility and Quantitative Assessment of Biodegradable Magnesium Alloy Stents by Intravascular Ultrasound and Optical Coherence Tomography
    Hetterich, Holger
    Guel, Burcu
    Koenig, Andreas, III
    Schober, Andreas
    Schiele, Thomas
    Klauss, Volker
    Rieber, Johannes
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A96 - A96
  • [39] Silk Fibroin as a Coating Polymer for Sirolimus-Eluting Magnesium Alloy Stents
    Xu, Wei
    Yagoshi, Kai
    Asakura, Tetsuo
    Sasaki, Makoto
    Niidome, Takuro
    ACS APPLIED BIO MATERIALS, 2020, 3 (01): : 531 - 538
  • [40] Advances in coatings on biodegradable magnesium alloys
    Zheng-Zheng Yin
    Wei-Chen Qi
    Rong-Chang Zeng
    Xiao-Bo Chen
    Chang-Dong Gu
    Shao-Kang Guan
    Yu-Feng Zheng
    Journal of Magnesium and Alloys, 2020, (01) : 42 - 65