Experimental Study on Secondary Effluent Disinfection with Ultrasound and Chlorine

被引:0
|
作者
Li, Zifu [1 ]
Zhao, Xin [1 ]
Deng, Furong [1 ]
Jin, Xin [1 ]
Wu, Hao [1 ]
机构
[1] Univ Sci & Technol Beijing, Sch Civil & Environm Engn, Beijing 100083, Peoples R China
来源
关键词
ultrasonic disinfection; chlorine disinfection; wasterwater disinfection; sterillization disinfection; WATER;
D O I
10.4028/www.scientific.net/AMR.383-390.3786
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Ultrasonic disinfection is safe and effective, but requires high power consumption. For economic considerations, ultrasound and chlorine can be combined to promote a wider range of applications. In this paper, we investigated the disinfection effect of secondary effluent with low-frequency ultrasound and sodium hypochlorite. The optimal conditions were determined by changing the ultrasound intensity, exposure time, chlorine dosage, and chlorine contact time. The results showed that ultrasound can significantly enhance the effects of chlorine disinfection. When the coliform bacteria is 106 similar to 107CFU/L, the dosage of chlorine at 4 similar to 6mg/1 can meet the national discharge standard (less than 104 CFU/L). However, the chlorine dosage can be further reduced to 1 similar to 2mg/l if we add 30 s of ultrasonic radiation, thereby reducing the disinfection by-products. Orthogonal experimental results show that the relative importance of the disinfection factors: chlorine dosage> ultrasonic irradiation time >chlorine contact time> ultrasound intensity.
引用
收藏
页码:3786 / 3791
页数:6
相关论文
共 50 条
  • [31] Irrigating Lettuce with Wastewater Effluent: Does Disinfection with Chlorine Dioxide Inactivate Viruses?
    Lopez-Galvez, F.
    Randazzo, W.
    Vasquez, A.
    Sanchez, G.
    Decol, L. Tombini
    Aznar, R.
    Gil, M. I.
    Allende, Ana
    JOURNAL OF ENVIRONMENTAL QUALITY, 2018, 47 (05) : 1139 - 1145
  • [32] WASTE STABILIZATION LAGOON MICROORGANISM REMOVAL EFFICIENCY AND EFFLUENT DISINFECTION WITH CHLORINE.
    Johnson, Bruce A.
    Wight, Jeffrey L.
    Bowles, David S.
    Reynolds, James H.
    Middlebrooks, E.Joe
    Environmental Protection Technology Series. EPA, 1979, (600 /2-79-018):
  • [33] Disinfection of constructed wetland effluent by in situ electrochemical chlorine production for water reuse
    Mosquera-Romero, Suanny
    Prevoteau, Antonin
    Arends, Jan B. A.
    Rousseau, Diederik P. L.
    Dominguez-Granda, Luis
    Rabaey, Korneel
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2021, 8 (01) : 98 - 107
  • [34] Advanced Treatment of Municipal Wastewater Effluent by Coagulation/Sedimentation and Chlorine Dioxide Disinfection
    Cheng, Lihua
    He, Aihua
    Bi, Xuejun
    Wang, Qi
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 2792 - 2796
  • [35] Ozone provides alternative for secondary effluent disinfection. I
    Nebel, C.
    Gottschling, R.D.
    Unangst, P.C.
    1976, 123 (04): : 76 - 78
  • [36] Modeling of slow sand filtration for disinfection of secondary clarifier effluent
    Langenbach, K.
    Kuschk, P.
    Horn, H.
    Kaestner, M.
    WATER RESEARCH, 2010, 44 (01) : 159 - 166
  • [37] Peracetic acid for secondary effluent disinfection: a comprehensive performance assessment
    Antonelli, M.
    Turolla, A.
    Mezzanotte, V.
    Nurizzo, C.
    WATER SCIENCE AND TECHNOLOGY, 2013, 68 (12) : 2638 - 2644
  • [38] Electrochemical disinfection of secondary wastewater treatment plant (WWTP) effluent
    Perez, G.
    Gomez, P.
    Ibanez, R.
    Ortiz, I.
    Urtiaga, A. M.
    WATER SCIENCE AND TECHNOLOGY, 2010, 62 (04) : 892 - 897
  • [39] DISINFECTION OF EFFLUENT BY COMBINATIONS OF EQUAL DOSES OF CHLORINE DIOXIDE AND CHLORINE ADDED SIMULTANEOUSLY OVER VARYING CONTACT TIMES
    KATZ, A
    NARKIS, N
    ORSHANSKY, F
    FRIEDLAND, E
    KOTT, Y
    WATER RESEARCH, 1994, 28 (10) : 2133 - 2138
  • [40] DISINFECTION WITH CHLORINE AND CHLORINE DIOXIDE
    AIETA, EM
    ROBERTS, PV
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1983, 109 (04): : 783 - 799