Experimental Study on Secondary Effluent Disinfection with Ultrasound and Chlorine

被引:0
|
作者
Li, Zifu [1 ]
Zhao, Xin [1 ]
Deng, Furong [1 ]
Jin, Xin [1 ]
Wu, Hao [1 ]
机构
[1] Univ Sci & Technol Beijing, Sch Civil & Environm Engn, Beijing 100083, Peoples R China
来源
关键词
ultrasonic disinfection; chlorine disinfection; wasterwater disinfection; sterillization disinfection; WATER;
D O I
10.4028/www.scientific.net/AMR.383-390.3786
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Ultrasonic disinfection is safe and effective, but requires high power consumption. For economic considerations, ultrasound and chlorine can be combined to promote a wider range of applications. In this paper, we investigated the disinfection effect of secondary effluent with low-frequency ultrasound and sodium hypochlorite. The optimal conditions were determined by changing the ultrasound intensity, exposure time, chlorine dosage, and chlorine contact time. The results showed that ultrasound can significantly enhance the effects of chlorine disinfection. When the coliform bacteria is 106 similar to 107CFU/L, the dosage of chlorine at 4 similar to 6mg/1 can meet the national discharge standard (less than 104 CFU/L). However, the chlorine dosage can be further reduced to 1 similar to 2mg/l if we add 30 s of ultrasonic radiation, thereby reducing the disinfection by-products. Orthogonal experimental results show that the relative importance of the disinfection factors: chlorine dosage> ultrasonic irradiation time >chlorine contact time> ultrasound intensity.
引用
收藏
页码:3786 / 3791
页数:6
相关论文
共 50 条
  • [21] Field Experiments of Chlorine Demand in Disinfection of Treated Primary Effluent
    Lee, Joseph H. W.
    Qiao, Q. S.
    Chan, S. N.
    Choi, K. W.
    Huang, Ju-Chang
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2017, 143 (11)
  • [22] Improving chlorine disinfection of wastewater by ultrasound application
    Blume, T
    Neis, U
    WATER SCIENCE AND TECHNOLOGY, 2005, 52 (10-11) : 139 - 144
  • [23] Data for comparison of chlorine dioxide and chlorine disinfection power in a real dairy wastewater effluent
    Akhlaghi, Maliheh
    Dorost, Amin
    Karimyan, Kamaladdin
    Narooie, Mohammad Reza
    Sharafi, Hooshmand
    DATA IN BRIEF, 2018, 18 : 886 - 890
  • [24] Evaluation of a chlorine dioxide secondary disinfection system
    Sidari, FP
    VanBriesen, J
    WEM-WATER ENGINEERING & MANAGEMENT, 2002, 149 (11): : 29 - 33
  • [25] Application of chlorine dioxide for secondary effluent polishing
    F. Vaezi
    K. Naddafi
    F. Karimi
    M. Alimohammadi
    International Journal of Environmental Science & Technology, 2004, 1 (2): : 97 - 101
  • [26] Feasibility study of UV disinfection for agricultural reuse of secondary level effluent in Korea
    Yoon, CG
    Chung, KW
    Ham, JH
    Jeon, JH
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2004, 39 (03): : 835 - 846
  • [27] Lab Scale Study on Synergistic Disinfection of WWTPS Secondary Effluent by Ultrasonic and Ozone
    Wu, Hao
    Li, Zifu
    Jin, Xin
    Zhao, Xin
    Deng, Furong
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 4751 - 4756
  • [28] Secondary effluent disinfection: PAA long term efficiency
    Antonelli, M.
    Rossi, S.
    Mezzanotte, V.
    Nurizzo, C.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (15) : 4771 - 4775
  • [29] The influence of filtration on ultraviolet disinfection of secondary effluent for microirrigation
    Hills, DJ
    Tajrishy, MA
    Tchobanoglous, G
    TRANSACTIONS OF THE ASAE, 2000, 43 (06): : 1499 - 1505
  • [30] Ultraviolet disinfection of secondary and tertiary effluent in the Mediterranean region
    Andreadakis, A
    Mamais, D
    Christoulas, D
    Kabylafka, S
    WATER SCIENCE AND TECHNOLOGY, 1999, 40 (4-5) : 253 - 260