Slat collimator design issues for dual-head coincidence Imaging systems

被引:4
|
作者
Joung, J [1 ]
Miyaoka, RS [1 ]
Kohlmyer, SG [1 ]
Harrison, RL [1 ]
Lewellen, TK [1 ]
机构
[1] Univ Washington, Image Res Labs, Dept Radiol, Seattle, WA 98195 USA
关键词
dual-head coincidence imaging (DHCI); noise; equivalent count (NEC); salt collimator;
D O I
10.1109/TNS.2002.998741
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper investigates optimum slat collimator design parameters for dual-head coincidence imaging (DHCI) systems. Noise equivalent count (NEC) rate was examined with respect to the activity concentration under various system conditions. All results are derived from Monte Carlo simulations with a digital anthropomorphic (Zubal) phantom. The DHCI system was modeled after the Millennium VG gamma camera (GEMS, Waukesha, WI). The dead-time characteristics of the camera were experimentally determined. Our results suggests that substantial NEC gains can be achieved by varying the slat-to-slat separation, such that the peak of the NEC curve is located at clinically relevant levels (i.e., 0.07 similar to 0.10 muCi/cc). The NEC was also found to increase with the use of longer slats with appropriately selected slat-to-slat separation. Furthermore, the NEC performance also depends on the count-rate performance (i.e., dead-time losses) of the system. Therefore, as improvements are made to the count-rate capabilities of DHCI systems, the slat geometry should be modified. Further study is required to determine the effect that slat collimator design has on image quality and lesion detection for clinically realistic imaging situations.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [41] Cardiac fluorine-18 fluorodeoxyglucose imaging using a dual-head gamma camera with coincidence detection: A clinical pilot study
    De Sutter, Johan
    De Winter, Frederic
    Van De Wiele, Christophe
    De Bondt, Pieter
    D'Asseler, Yves
    Dierckx, Rudi
    European Journal of Nuclear Medicine and Molecular Imaging, 2000, 27 (06) : 676 - 685
  • [43] SURGICAL PROBE DESIGN FOR A COINCIDENCE IMAGING-SYSTEM WITHOUT A COLLIMATOR
    SAFFER, JR
    BARRETT, HH
    BARBER, HB
    WOOLFENDEN, JM
    LECTURE NOTES IN COMPUTER SCIENCE, 1991, 511 : 8 - 22
  • [44] The clinical value of 18F-FDG detection with a dual-head coincidence camera: a review
    I. Ak
    J. Blokland
    E. Pauwels
    M. Stokkel
    European Journal of Nuclear Medicine, 2001, 28 : 763 - 778
  • [45] SURGICAL PROBE DESIGN FOR A COINCIDENCE IMAGING-SYSTEM WITHOUT A COLLIMATOR
    SAFFER, JR
    BARRETT, HH
    BARBER, HB
    WOOLFENDEN, JM
    IMAGE AND VISION COMPUTING, 1992, 10 (06) : 333 - 341
  • [46] 18F fluorodeoxyglucose imaging with coincidence dual-head gamma camera (Co-PET) for staging and management of head and neck cancer.
    Lin, P
    Chu, J
    Pocock, N
    Kiat, H
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 289P - 289P
  • [47] Comparison of dual-head coincidence gamma camera FDG imaging with FDG PET in detection of breast cancer and axillary lymph node metastasis
    Yutani, K
    Tatsumi, M
    Shiba, E
    Kusuoka, H
    Nishimura, T
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (06) : 1003 - 1008
  • [48] Dual-head coincidence gamma camera FDG pet in patients with colorectal and anal cancer.
    Bruun, E
    Hansen, ILK
    GASTROENTEROLOGY, 2000, 118 (04) : A257 - A257
  • [49] Detection of occult colorectal cancer recurrences by FDG scan on a dual-head coincidence gammacamera (CDET).
    Montravers, F
    Grahek, D
    Kerrou, K
    Younsi, N
    Houry, S
    Lacaine, F
    Huguier, M
    Talbot, JN
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 978 - 978
  • [50] Evaluation of F-18-FDG dual-head tomography with coincidence in the detection of lung lesions
    Wang, RF
    Wang, XX
    Chen, HY
    Liu, TL
    Li, J
    Lin, JH
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1031 - 1031