Comparison of air kerma standards for medium-energy x radiation between the MKEH and the IAEA

被引:1
|
作者
Csete, Istvan [1 ]
Czap, Ladislav [2 ]
Gomola, Igor [2 ]
机构
[1] Hungarian Trade Licensing Off MKEH, Budapest, Hungary
[2] IAEA, A-1400 Vienna, Austria
关键词
D O I
10.1088/0026-1394/49/1A/06011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A comparison of the air kerma standards for medium-energy x radiation was performed between the MKEH and the IAEA. Two reference class ionization chambers of the IAEA, traceable to the PTB with volumes 1000 cm(3) and 100 cm(3), and the ISO 4037 N-40, N-60, N-120 and N-300 standard beam qualities were selected for the comparison. The calibration coefficients, N-K, were determined for both chambers at the MKEH in August 2011 and before and after this at the IAEA Dosimetry Laboratory. The comparison ratio of the calibration coefficients normalized to the previous comparison results of the PTB and MKEH primary air kerma standards were in the range from 0.989 to 0.994 for the beam qualities used. The relative expanded ( k = 2) uncertainty for each of these ratios is around 2 %.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Comparison of the NIST and BIPM standards for air kerma in medium-energy x-rays
    Burns, D. T.
    O'Brien, M.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2006, 111 (05) : 385 - 391
  • [2] Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the MKEH, Hungary and the BIPM in medium-energy x-rays
    Burns, D. T.
    Csete, I.
    Roger, P.
    METROLOGIA, 2011, 48
  • [3] Comparison of the standards for air kerma of the MKEH and the BIPM for 137Cs gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Csete, I.
    Machula, G.
    METROLOGIA, 2010, 47
  • [4] Comparison of the NIST and BIPM medium-energy X-ray air-kerma measurements
    Burns, DT
    Lamperti, P
    O'Brien, M
    Boutillon, M
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2003, 108 (05) : 383 - 389
  • [5] Absolute measurement of air kerma in medium-energy x-rays
    Wu, Jinjie
    Yang, Yuandi
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2010, 31 (8 SUPPL.): : 152 - 156
  • [6] Comparison of the air-kerma standards of the NRPA, the STUK, the SSM and the LNE-LNHB in medium-energy x-rays
    Bjerke, H.
    Plagnard, J.
    Bordy, J-M
    Kosunen, A.
    Lindholm, C.
    Persson, L.
    Hetland, P. O.
    METROLOGIA, 2018, 55
  • [7] Comparison of the air kerma standards of the IAEA and the BIPM in mammography x-rays
    Kessler, C.
    Burns, D.
    Czap, L.
    Csete, I.
    Gomola, I.
    METROLOGIA, 2013, 50
  • [8] The performance of the INER improved free-air ionization chamber in the comparison of air kerma calibration coefficients for medium-energy X-rays
    Lee, JH
    Kotler, LH
    Büermann, L
    Hwang, WS
    Chiu, JH
    Wang, CF
    RADIATION MEASUREMENTS, 2005, 39 (01) : 1 - 10
  • [9] Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NIM, China and the BIPM in medium-energy x-rays
    Burns, D. T.
    Kessler, C.
    Wu Jinjie
    Wang Peiwei
    METROLOGIA, 2017, 54
  • [10] Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the ARPANSA, Australia, and the BIPM in medium-energy x-rays
    Burns, D. T.
    Kessler, C.
    Hanlon, M.
    Bailey, T.
    Oliver, C.
    Butler, D.
    METROLOGIA, 2021, 58 (1A)