Real-time tool wear monitoring using thin-film thermocouple

被引:63
|
作者
Li, Tianxiang [1 ]
Shi, Tielin [1 ,2 ]
Tang, Zirong [1 ,2 ]
Liao, Guanglan [1 ,2 ]
Duan, Jian [1 ]
Han, Jinghui [1 ]
He, Zhaopeng [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Digital Mfg Equipment & Technol, Wuhan 430074, Peoples R China
[2] Huazhong Univ Sci & Technol, Wuhan Natl Lab Optoelect, Wuhan 430074, Peoples R China
基金
美国国家科学基金会;
关键词
Tool wear monitoring; PCBN; Thin-film thermocouple; Cutting temperature; TEMPERATURE-MEASUREMENT; RAKE FACE; SENSORS;
D O I
10.1016/j.jmatprotec.2020.116901
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Due to harsh environment in the cutting area, access to the cutting region is still limited for the existing temperature sensors. As such, measuring temperature signals remains a challenge for real-time tool wear monitoring. In this paper, a polycrystalline cubic boron nitride (PCBN) cutting tool embedded with thin-film thermocouple (TFTC) was devised and used for tool wear monitoring during the cutting of hardened AISI O2 tool steel. A detailed manufacturing process of the smart tool was introduced. Performance tests for the smart insert were evaluated and results showed that the embedded TFTC had a sensitivity of 14.4 mu V/degrees C, good dynamic response, and functional validity. Wear experiments were implemented under two sets of cutting parameters to explore the relationship between cutting temperature and tool wear. The results showed that the increased maximum cutting temperature could well reflect the progression of flank wear. Obvious fluctuation in temperature signal could also well reflect the abnormal condition of the tool. The devised smart tool will be useful for determining optimum cutting parameters and extending tool life.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Metallic thin-film thermocouple for thermoelectric microgenerators
    Castano, E
    Revuelto, E
    Martin, MC
    GarciaAlonso, A
    Gracia, FJ
    SENSORS AND ACTUATORS A-PHYSICAL, 1997, 60 (1-3) : 65 - 67
  • [22] Real-time tool wear estimation using cutting force measurements
    Glass, K
    Colbaugh, R
    1996 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, PROCEEDINGS, VOLS 1-4, 1996, : 3067 - 3072
  • [23] Real-time X-ray reflectometry during thin-film processing
    Peverini, L.
    Kozhevnikov, I.
    Ziegler, E.
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2007, 204 (08): : 2785 - 2791
  • [24] Thin-Film Thermocouple Array for Time-Resolved Local Temperature Mapping
    Liu, Haixiao
    Sun, Weiqiang
    Chen, Qing
    Xu, Shengyong
    IEEE ELECTRON DEVICE LETTERS, 2011, 32 (11) : 1606 - 1608
  • [25] Real-time simulation of thin-film interference with surface thickness variation using the shallow water equations
    Gu, Mingyi
    Dai, Jiajia
    Chen, Jiazhou
    Yan, Ke
    Huang, Jing
    COMPUTER ANIMATION AND VIRTUAL WORLDS, 2024, 35 (04)
  • [26] Temperature measurement performance of thin-film thermocouple cutting tool in turning titanium alloy
    Lian, Yunsong
    Chen, Xiande
    Zhang, Tianyuan
    Liu, Chao
    Lin, Liangliang
    Lin, Fengtian
    Li, Yousheng
    Chen, Youliang
    Zhang, Min
    Zhou, Wei
    CERAMICS INTERNATIONAL, 2023, 49 (02) : 2250 - 2261
  • [27] Real-time adsorption/desorption thin-film optical monitor using a windowless reflective silicon photodetector
    Univ of New Orleans, New Orleans, United States
    Rev Sci Instrum, 8 (4362-4366):
  • [28] Real-time monitoring of wear debris using electrostatic sensing techniques
    Harvey, T. J.
    Morris, S.
    Wang, L.
    Wood, R. J. K.
    Powrie, H. E. G.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 2007, 221 (J1) : 27 - 40
  • [29] Thin-film wear sensors
    不详
    INDUSTRIAL CERAMICS, 1998, 18 (02): : 115 - 115
  • [30] THIN-FILM WEAR SENSORS
    HAHN, FW
    WEAR, 1981, 74 (01) : 157 - 164