4D Liver Ultrasound Registration

被引:0
|
作者
Banerjee, Jyotirmoy [1 ,2 ]
Klink, Camiel [1 ]
Peters, Edward D. [2 ]
Niessen, Wiro J. [1 ,2 ]
Moelker, Adriaan [1 ]
van Walsum, Theo [1 ,2 ]
机构
[1] Erasmus MC, Dept Radiol, Rotterdam, Netherlands
[2] Erasmus MC, Dept Med Informat, Rotterdam, Netherlands
来源
关键词
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
In this paper we present a rigid registration approach for 4D ultrasound (US) datasets, where images are registered over time. The 3D registration approach preceding the 4D registration consists of two main steps -block-matching and outlier rejection. The outlier rejection step removes the spurious matchings' from the block-matching module and ensures inverse consistency. For 4D registration, we perform registration of consecutive US volumes over the time series. Transformation between any two frames is estimated by taking the product of all the intermediate transforms. To avoid accumulation of error over the series of transformations, a long range feedback mechanism is proposed. A mean total registration error of 1 mm is achieved across six 4D ultrasound sequences of human liver with an execution speed of 10 Hz.
引用
收藏
页码:194 / 202
页数:9
相关论文
共 50 条
  • [21] 3D and 4D Ultrasound: A Text and Atlas
    Cosgrove, David
    ULTRASOUND, 2005, 13 (03) : 207 - 207
  • [22] 3D - 4D Ultrasound in Obstetrics and Gynecology
    Purandare, C. N.
    JOURNAL OF OBSTETRICS AND GYNECOLOGY OF INDIA, 2006, 56 (01): : 22 - 24
  • [23] A Symmetric 4D Registration Algorithm for Respiratory Motion Modeling
    Xu, Huanhuan
    Li, Xin
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2013, PT II, 2013, 8150 : 149 - 156
  • [24] 4D scan registration with the SR-3000 LIDAR
    Stipes, Jason A.
    Cole, John G. P.
    Humphreys, John
    2008 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-9, 2008, : 2988 - +
  • [25] Automatic contour generation of 4D CT by deformable registration
    Duan, Zhuolei
    Zhou, Fugen
    Liu, Bo
    Deng, Xiaowu
    Chen, Ming
    Huang, Xiaoyan
    PACIIA: 2008 PACIFIC-ASIA WORKSHOP ON COMPUTATIONAL INTELLIGENCE AND INDUSTRIAL APPLICATION, VOLS 1-3, PROCEEDINGS, 2008, : 1170 - +
  • [26] Consistent estimation of cardiac motions by 4D image registration
    Shen, DG
    Sundar, H
    Xue, Z
    Fan, Y
    Litt, H
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2, 2005, 3750 : 902 - 910
  • [27] Multimodality and 4D image registration: Methods and clinical use
    Kessler, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2618 - 2618
  • [28] Feature-aligned 4D Spatiotemporal Image Registration
    Xu, Huanhuan
    Chen, Peizhi
    Yu, Wuyi
    Sawant, Amit
    Iyengar, S. S.
    Li, Xin
    2012 21ST INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION (ICPR 2012), 2012, : 2639 - 2642
  • [29] Shape tracking and registration for 4D visualization of MRI and structure
    Cheng, Irene
    Nilufar, Sharmin
    Basu, Anup
    Goebel, Randy
    ADVANCES IN VISUAL COMPUTING, PT 1, 2006, 4291 : 253 - +
  • [30] ADVANCES IN DEFORMABLE IMAGE REGISTRATION OF THORACIC 4D CT
    Sarrut, D.
    Vandemeulebroucke, J.
    Rit, S.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S188 - S189