A Symmetric 4D Registration Algorithm for Respiratory Motion Modeling

被引:0
|
作者
Xu, Huanhuan [1 ]
Li, Xin [1 ]
机构
[1] Louisiana State Univ, Sch Elect Engn & Comp Sci, Baton Rouge, LA 70803 USA
关键词
4D Image Registration; Respiratory Motion Modeling; IMAGE REGISTRATION;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We propose an effective 4D image registration algorithm for dynamic volumetric lung images. The registration will construct a deforming 3D model with continuous trajectory and smooth spatial deformation, and the model interpolates the interested region in the 4D (3D+T) CT images. The resultant non-rigid transformation is represented using two 4D B-spline functions, indicating a forward and an inverse 4D parameterization respectively. The registration process solves these two functions by minimizing an objective function that penalizes intensity matching error, feature alignment error, spatial and temporal non-smoothness, and inverse inconsistency. We test our algorithm for respiratory motion estimation on public benchmarks and on clinic lung CT data. The experimental results demonstrate the efficacy of our algorithm.
引用
收藏
页码:149 / 156
页数:8
相关论文
共 50 条
  • [1] CONSISTENT FEATURE-ALIGNED 4D IMAGE REGISTRATION FOR RESPIRATORY MOTION MODELING
    Xu, Huanhuan
    Li, Xin
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 584 - 587
  • [2] Statistical Modeling of 4D Respiratory Lung Motion Using Diffeomorphic Image Registration
    Ehrhardt, Jan
    Werner, Rene
    Schmidt-Richberg, Alexander
    Handels, Heinz
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (02) : 251 - 265
  • [3] A conditional registration network for continuous 4D respiratory motion synthesis
    Sang, Yudi
    Ruan, Dan
    MEDICAL PHYSICS, 2023, 50 (07) : 4379 - 4387
  • [4] 4D Motion Modeling: Estimation of Respiratory Motion for Radiation Therapy
    Ehrhardt, J.
    Werner, R.
    Schmidt-Richberg, A.
    Handels, H.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 2166 - 2169
  • [5] Modeling respiratory motion variations in the 4D NCAT phantom
    Segars, W. P.
    Chen, G. T. Y.
    Tsui, B. M. W.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2677 - +
  • [6] Modeling respiratory motion variations in the 4D NCAT phantom
    Segars, W. P.
    Mori, S.
    Chen, G. T. Y.
    Tsui, B. M. W.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4531 - +
  • [7] Synthesizing Continuous 4D Respiratory Motion Using a Conditional Registration Network
    Sang, Y.
    Ruan, D.
    MEDICAL PHYSICS, 2022, 49 (06) : E159 - E160
  • [8] A Composite Registration Framework for Respiratory Motion Modelling from 4D MRI
    Golkar, Ehsan
    Abd Rahni, Ashrani Aizzuddin
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [9] Modeling respiratory motion for reducing motion artifacts in 4D CT images
    Zhang, Yongbin
    Yang, Jinzhong
    Zhang, Lifei
    Court, Laurence E.
    Balter, Peter A.
    Dong, Lei
    MEDICAL PHYSICS, 2013, 40 (04)
  • [10] Nonrigid Registration and Template Matching for Coronary Motion Modeling from 4D CTA
    Zhang, Dong Ping
    Risser, Laurent
    Friman, Ola
    Metz, Coert
    Neefjes, Lisan
    Mollet, Nico
    Niessen, Wiro
    Rueckert, Daniel
    BIOMEDICAL IMAGE REGISTRATION, 2010, 6204 : 210 - +