Microfluidic biosensor for the detection of DNA by fluorescence enhancement and the following streptavidin detection by fluorescence quenching

被引:24
|
作者
Wang, Jun [1 ,2 ,3 ]
Aki, Michihiko [4 ]
Onoshima, Daisuke [1 ,2 ,5 ]
Arinaga, Kenji [4 ]
Kaji, Noritada [1 ,2 ,4 ]
Tokeshi, Manabu [1 ,2 ,6 ]
Fujita, Shozo [4 ]
Yokoyama, Naoki [4 ]
Baba, Yoshinobu [1 ,2 ,5 ,7 ]
机构
[1] Nagoya Univ, Dept Appl Chem, Grad Sch Engn, Nagoya, Aichi 46401, Japan
[2] Nagoya Univ, MEXT Innovat Res Ctr Prevent Med Engn, Nagoya, Aichi 4648601, Japan
[3] Chalmers Univ Technol, Dept Chem & Biol Engn, S-41296 Gothenburg, Sweden
[4] Fujitsu Labs Ltd, Tokyo, Japan
[5] Nagoya Univ, Res Ctr Innovat Nanobiodevice 1, Nagoya, Aichi 4648603, Japan
[6] Hokkaido Univ, Grad Sch Engn, Div Biotechnol & Macromol Chem, Sapporo, Hokkaido, Japan
[7] Natl Inst Adv Ind Sci & Technol, Hlth Technol Res Ctr, Takamatsu, Kagawa, Japan
来源
基金
日本学术振兴会;
关键词
Microfluidic biosensor; Fluorescence switching; Complementary ssDNA; Streptavidin; MOLECULAR-BEACON; NUCLEIC-ACID; SENSITIVE DETECTION; ANALYSIS SYSTEMS; THIAZOLE ORANGE; PROBES; INTERROGATION; ARRAY;
D O I
10.1016/j.bios.2013.07.058
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We reported an optical DNA/protein microfluidic sensor which consists of single stranded (ss) DNA-Cy3 probes on gold surface and simple line-shape microfluidic channel. These ssDNA-Cy3 probes with random sequence in bulk solution or on gold surface exhibits fluorescence enhancement after binding with complementary ssDNA (cssDNA) targets. Particularly it did not require complicated design or hairpin-like stem-loop conformation, which made it easier to be made and applied in analytes detection by fluorescence switching techniques. Using ssDNA-cy3 probes attached on gold surface in a microfluidic channel, strong fluorescence enhancement was measured by ssDNA with cssDNA binding or ssDNA with cssDNA-biotin binding. The following introduction of streptavidin resulted in fluorescence quenching (fluorescence decrease) because of the binding of hybridized DNA-biotin with streptavidin. This sensor showed strong affinity and high sensitivity toward the streptavidin, the minimum detectable concentration for streptavidin was 1 pM, equating to an absolute detection limit of 60 amol in this microfluidic channel. Microfluidic channel height and flow rate is optimized to increase surface reaction efficiency and fluorescence switching efficiency. In contrast to previously reported optical molecular beacon approach, this sensor can be used not only for the detection of cssDNA target, but also for the detection of streptavidin. This microfluidic sensor offers the promise of analyzing kinds of molecular targets or immunoreactions. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:280 / 285
页数:6
相关论文
共 50 条
  • [31] A Sensitive Detection Method for Carbamate Pesticide by Fluorescence Biosensor
    Zhang Hao
    Liu Chuan-Zhi
    Xu Ying
    Guo Yuan
    Song Yu
    Yu Yuan-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (01) : 104 - 108
  • [32] Multiphoton fluorescence quenching of conjugated polymers for TNT detection
    Narayanan, Aditya
    Varnavski, Oleg P.
    Swager, Timothy M.
    Goodson, Theodore, III
    JOURNAL OF PHYSICAL CHEMISTRY C, 2008, 112 (04): : 881 - 884
  • [33] A unique fluorescence biosensor for selective detection of tryptophan and histidine
    Sutariya, Pinkesh G.
    Pandya, Alok
    Lodha, Anand
    Menon, Shobhana K.
    ANALYST, 2014, 139 (19) : 4794 - 4798
  • [34] Optical fluorescence biosensor for plant water stress detection
    Chong, Jenny P. C.
    Liew, O. W.
    Li, B. Q.
    Asundi, A. K.
    SARATOV FALL MEETING 2006: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE VIII, 2007, 6535
  • [35] A Fluorescence Biosensor for Detection of Mercury Ion Based on Oligonucleotide
    Liu Chen-Guang
    Wang Jiu-Jun
    Zhang Xing-Ping
    Yang Hua-Lin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (02) : 163 - 168
  • [36] Sensitive and selective detection of cesium via fluorescence quenching
    Radaram, Bhasker
    Mako, Teresa
    Levine, Mindy
    DALTON TRANSACTIONS, 2013, 42 (46) : 16276 - 16278
  • [37] Fluorescence quenching based alkaline phosphatase activity detection
    Mei, Yaqi
    Hu, Qiong
    Zhou, Baojing
    Zhang, Yonghui
    He, Minhui
    Xu, Ting
    Li, Feng
    Kong, Jinming
    TALANTA, 2018, 176 : 52 - 58
  • [38] Fluorescence quenching as an indirect detection method for nitrated explosives
    Goodpaster, JV
    McGuffin, VL
    ANALYTICAL CHEMISTRY, 2001, 73 (09) : 2004 - 2011
  • [39] A fluorescence biosensor for VEGF detection based on DNA assembly structure switching and isothermal amplification
    Li, Junlong
    Sun, Kexin
    Chen, Zhongping
    Shi, Jifei
    Zhou, Dandan
    Xie, Guoming
    BIOSENSORS & BIOELECTRONICS, 2017, 89 : 964 - 969
  • [40] A new miniaturized multiarray biosensor system for fluorescence detection
    Tibuzzi, A.
    Rea, G.
    Pezzotti, G.
    Esposito, D.
    Johanningmeier, U.
    Giardi, M. T.
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2007, 19 (39)