Microfluidic biosensor for the detection of DNA by fluorescence enhancement and the following streptavidin detection by fluorescence quenching

被引:24
|
作者
Wang, Jun [1 ,2 ,3 ]
Aki, Michihiko [4 ]
Onoshima, Daisuke [1 ,2 ,5 ]
Arinaga, Kenji [4 ]
Kaji, Noritada [1 ,2 ,4 ]
Tokeshi, Manabu [1 ,2 ,6 ]
Fujita, Shozo [4 ]
Yokoyama, Naoki [4 ]
Baba, Yoshinobu [1 ,2 ,5 ,7 ]
机构
[1] Nagoya Univ, Dept Appl Chem, Grad Sch Engn, Nagoya, Aichi 46401, Japan
[2] Nagoya Univ, MEXT Innovat Res Ctr Prevent Med Engn, Nagoya, Aichi 4648601, Japan
[3] Chalmers Univ Technol, Dept Chem & Biol Engn, S-41296 Gothenburg, Sweden
[4] Fujitsu Labs Ltd, Tokyo, Japan
[5] Nagoya Univ, Res Ctr Innovat Nanobiodevice 1, Nagoya, Aichi 4648603, Japan
[6] Hokkaido Univ, Grad Sch Engn, Div Biotechnol & Macromol Chem, Sapporo, Hokkaido, Japan
[7] Natl Inst Adv Ind Sci & Technol, Hlth Technol Res Ctr, Takamatsu, Kagawa, Japan
来源
基金
日本学术振兴会;
关键词
Microfluidic biosensor; Fluorescence switching; Complementary ssDNA; Streptavidin; MOLECULAR-BEACON; NUCLEIC-ACID; SENSITIVE DETECTION; ANALYSIS SYSTEMS; THIAZOLE ORANGE; PROBES; INTERROGATION; ARRAY;
D O I
10.1016/j.bios.2013.07.058
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We reported an optical DNA/protein microfluidic sensor which consists of single stranded (ss) DNA-Cy3 probes on gold surface and simple line-shape microfluidic channel. These ssDNA-Cy3 probes with random sequence in bulk solution or on gold surface exhibits fluorescence enhancement after binding with complementary ssDNA (cssDNA) targets. Particularly it did not require complicated design or hairpin-like stem-loop conformation, which made it easier to be made and applied in analytes detection by fluorescence switching techniques. Using ssDNA-cy3 probes attached on gold surface in a microfluidic channel, strong fluorescence enhancement was measured by ssDNA with cssDNA binding or ssDNA with cssDNA-biotin binding. The following introduction of streptavidin resulted in fluorescence quenching (fluorescence decrease) because of the binding of hybridized DNA-biotin with streptavidin. This sensor showed strong affinity and high sensitivity toward the streptavidin, the minimum detectable concentration for streptavidin was 1 pM, equating to an absolute detection limit of 60 amol in this microfluidic channel. Microfluidic channel height and flow rate is optimized to increase surface reaction efficiency and fluorescence switching efficiency. In contrast to previously reported optical molecular beacon approach, this sensor can be used not only for the detection of cssDNA target, but also for the detection of streptavidin. This microfluidic sensor offers the promise of analyzing kinds of molecular targets or immunoreactions. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:280 / 285
页数:6
相关论文
共 50 条
  • [21] A new ratiometric fluorescence detection of heparin based on the combination of the aggregation-induced fluorescence quenching and enhancement phenomena
    Gu, Xinggui
    Zhang, Guanxin
    Zhang, Deqing
    ANALYST, 2012, 137 (02) : 365 - 369
  • [22] A fluorescence quenching test for the detection of flavonoid transformation
    Schoefer, L
    Braune, A
    Blaut, M
    FEMS MICROBIOLOGY LETTERS, 2001, 204 (02) : 277 - 280
  • [23] Quenching of Upconversion Nanoparticle Fluorescence for Tetracyclines Detection
    Vyshnava, Satyanarayana Swamy
    Dowlathabad, Muralidhara Rao
    BIONANOSCIENCE, 2024, 14 (02) : 619 - 629
  • [24] Fluorescence detection methods for microfluidic droplet platforms
    Casadevall i Solvas, Xavier
    Niu, Xize
    Leeper, Katherine
    Cho, Soongwon
    Chang, Soo-Ik
    Edel, Joshua B.
    deMello, Andrew J.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2011, (58):
  • [25] Fluorescence quenching of quantum dots by gold nanorods and its application to DNA detection
    Li, Xin
    Qian, Jun
    Jiang, Li
    He, Sailing
    APPLIED PHYSICS LETTERS, 2009, 94 (06)
  • [26] Au nanoparticles enhanced fluorescence detection of DNA hybridization in picoliter microfluidic droplets
    Zhu, Hongwei
    Wang, Guodong
    Xie, Donglei
    Cai, Bo
    Liu, Yumin
    Zhao, Xingzhong
    BIOMEDICAL MICRODEVICES, 2014, 16 (03) : 479 - 485
  • [27] Au nanoparticles enhanced fluorescence detection of DNA hybridization in picoliter microfluidic droplets
    Hongwei Zhu
    Guodong Wang
    Donglei Xie
    Bo Cai
    Yumin Liu
    Xingzhong Zhao
    Biomedical Microdevices, 2014, 16 : 479 - 485
  • [28] A sensitive fluorescence method for the detection of streptavidin based on target-induced DNA machine amplification
    Chen, Mingjian
    Deng, Zhiyi
    Ma, Changbei
    Zhao, Han
    Wu, Kefeng
    Wang, Kemin
    ANALYTICAL METHODS, 2018, 10 (16) : 1870 - 1874
  • [29] The Detection of p53 Gene via Fluorescence Quenching of Quantum Dot in Microfluidic Chip
    You, Jeong Ha
    Yoo, In Sang
    Yoon, Won Jung
    Kim, Jong Sung
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2012, 12 (05) : 4109 - 4114
  • [30] Novel biosensor system model based on fluorescence quenching by a fluorescent streptavidin and carbazole-labeled biotin
    Zhu, Xianwei
    Shinohara, Hiroaki
    Miyatake, Ryuta
    Hohsaka, Takahiro
    JOURNAL OF MOLECULAR RECOGNITION, 2016, 29 (10) : 485 - 491