An overview of electronic apex locators: part 2

被引:7
|
作者
Ali, R. [1 ]
Okechukwu, N. C. [2 ]
Brunton, P. [1 ]
Nattress, B. [1 ]
机构
[1] Leeds Dent Inst, Leeds LS2 9LU, W Yorkshire, England
[2] York Hosp, Senior House Off Oral & Maxillofacial Surg, York YO31 8HE, N Yorkshire, England
关键词
ROOT-CANAL LENGTH; IN-VITRO EVALUATION; CLINICAL-EVALUATION; VIVO EVALUATION; ZX; ACCURACY; FREQUENCY; DEVICE; TEETH;
D O I
10.1038/sj.bdj.2013.215
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A number of electronic apex locators are available for use during endodontic treatment. The use of third and fourth generation electronic apex locators (EAL) are recommended to help clinicians determine the apical limit of the root canal system (RCS). The presence of different irrigating media in the RCS does not impact significantly on the performance of third/fourth generation apex locators. The devices are most accurate at determining the apical limit when the attached endodontic file contacts the periodontal ligament space and the visual analogue displays 'Apex' or '0.' Given the accuracies of modern generation EALs, the clinician should be able to consistently identify the apical limit of the tooth under treatment. Their use in conjunction with appropriate radiographs and the clinician's knowledge of average RCS lengths and anatomy will maximise the successful outcome of any orthograde endodontic treatment.
引用
收藏
页码:227 / 231
页数:5
相关论文
共 50 条
  • [21] Influence of embedding media on the assessment of electronic apex locators
    Baldi, Jarcio V.
    Victorino, Fausto R.
    Bernardes, Ricardo A.
    de Moraes, Ivaldo G.
    Bramante, Colvis M.
    Garcia, Roberto B.
    Bernardineli, Norberti
    JOURNAL OF ENDODONTICS, 2007, 33 (04) : 476 - 479
  • [22] Accuracy of two electronic apex locators in primary teeth
    Bolan, Michele
    de Carvalho Rocha, Maria Jose
    ENDO-ENDODONTIC PRACTICE TODAY, 2010, 4 (01): : 49 - 54
  • [23] An in vivo comparison of five different electronic apex locators
    Al-Shaher, Abdulaziz A.
    Madi, Samar
    ENDO-ENDODONTIC PRACTICE TODAY, 2011, 5 (01): : 17 - 25
  • [24] In vivo comparison of the accuracy of two electronic apex locators
    Silveira, Luiz F. M.
    Petry, Fernanda V.
    Martos, Josue
    Neto, Joao B. C.
    AUSTRALIAN ENDODONTIC JOURNAL, 2011, 37 (02) : 70 - 72
  • [25] Electronic Apex Locators and their Implications in Contemporary Clinical Practice: A Review
    Shirazi, Zainab
    Al-Jadaa, Anas
    Saleh, Abdul Rahman
    OPEN DENTISTRY JOURNAL, 2023, 17
  • [26] IN-VITRO EVALUATION OF THE ACCURACY OF SEVERAL ELECTRONIC APEX LOCATORS
    CZERW, RJ
    FULKERSON, MS
    DONNELLY, JC
    WALMANN, JO
    JOURNAL OF ENDODONTICS, 1995, 21 (11) : 572 - 575
  • [27] The effect of coronal preflaring on the accuracy of two electronic apex locators
    Suryantoro, R.
    Meidyawati, R.
    Suprastiwi, E.
    1ST PHYSICS AND TECHNOLOGIES IN MEDICINE AND DENTISTRY SYMPOSIUM, 2017, 884
  • [28] An in vivo comparison of gradient and absolute impedance electronic apex locators
    Lauper, R
    Lutz, F
    Barbakow, F
    JOURNAL OF ENDODONTICS, 1996, 22 (05) : 260 - 263
  • [29] Modern electronic apex locators are reliable for determining root canal working length: How accurate are electronic apex locators in the determination of root canal length?
    Balto K.A.
    Evidence-Based Dentistry, 2006, 7 (2) : 31 - 32
  • [30] A comparison between two electronic apex locators:: an in vivo investigation
    Venturi, M
    Breschi, L
    INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (01) : 36 - 45