Performance tests for mammographic film-screen combinations: use of absolute techniques

被引:0
|
作者
Bor, Dogan [1 ]
Akdur, Kerime [1 ]
机构
[1] Ankara Univ, Dept Engn Phys, TR-06100 Ankara, Turkey
关键词
X-RAY-SPECTRA; OPTICAL-DENSITY; IMAGE QUALITY;
D O I
10.5152/dir.2013.032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE A performance comparison of film-screen combination used in mammography was conducted using conventional and new techniques. MATERIALS AND METHODS The performance of 30 mammographic film-screen combinations was evaluated by sensitometry, and the total performance was determined using phantom measurements. Quantum detection and light emission efficiency of the screens were also measured as an alternative technique for determining screen speeds. These efficiency measurements provided quantitative results for selecting the optimum beam quality. RESULTS Considering the image quality scores from three observers and the radiation doses obtained from the speed measurements, eight combinations were selected as being optimal. Only three of the mammographic film screen combinations in this group were the recommendations of manufacturers. CONCLUSION The total performance phantom can be effectively used for the qualitative check of image and provide speed information for mammographic film-screen combinations comparable to sensitometric techniques.
引用
收藏
页码:360 / 370
页数:11
相关论文
共 50 条
  • [41] The use of an interactive software program for quantitative characterization of microcalcifications on digitized film-screen mammograms
    Leichter, I
    Lederman, R
    Bamberger, P
    Novak, B
    Fields, S
    Buchbinder, SS
    INVESTIGATIVE RADIOLOGY, 1999, 34 (06) : 394 - 400
  • [42] COMPARISON OF DIFFERENT X-RAY-FILMS FOR THE DETECTION OF P-32 BY AUTORADIOGRAPHY BY USING DIFFERENT FILM-SCREEN COMBINATIONS
    HENKE, L
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1987, 25 (09): : 578 - 578
  • [43] ANALYSIS OF THE EFFECTS OF SCATTER, MTF AND SYSTEM GRADIENT ON LARGE OBJECT CONTRAST RESPONSE AND ABSOLUTE DOSE EFFICIENCY FOR FILM-SCREEN RADIOLOGY
    COHEN, G
    WAGNER, LK
    AMTEY, SR
    KEYES, G
    DIBIANCA, FA
    MEDICAL PHYSICS, 1980, 7 (04) : 431 - 431
  • [44] Reproducibility of screen-film performance tests - Developing standards
    Sluming, V
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 : 233 - 234
  • [45] The positive predictive value for diagnosis of breast cancer: Full-field digital mammography versus film-screen mammography in the diagnostic mammographic population
    Seo, Bo Kyoung
    Pisano, Etta D.
    Kuzmiak, Cherie M.
    Koomen, Marcia
    Pavic, Dag
    McLelland, Robert
    Lee, Yeonhee
    Cole, Elodia B.
    Mattingly, Dianne
    Lee, Juneyoung
    ACADEMIC RADIOLOGY, 2006, 13 (10) : 1229 - 1235
  • [46] A COMPARISON BETWEEN DIGITAL LUMINESCENCE RADIOGRAPHY (DLR) AND CONVENTIONAL FILM-SCREEN TECHNIQUES FOR PULMONARY FOCI - A CLINICAL-EVALUATION
    SCHWERMER, B
    WITTE, G
    SPIELMANN, RP
    NICOLAS, V
    FASSBENDER, T
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1990, 153 (02): : 161 - 166
  • [47] FORMAT PROPOSAL FOR A UNIVERSAL FILM-SCREEN SYSTEM FOR 35MM AND 16MM USE IN CINEMAS
    BERGGREN, GM
    JOURNAL OF THE SMPTE-SOCIETY OF MOTION PICTURE AND TELEVISION ENGINEERS, 1974, 83 (12): : 986 - 986
  • [48] ASSESSMENT OF CONGESTIVE-HEART-FAILURE IN CHEST RADIOGRAPHS - OBSERVER PERFORMANCE WITH 2 COMMON FILM-SCREEN SYSTEMS
    HENRIKSSON, L
    SUNDIN, A
    SMEDBY, O
    ALBREKTSSON, P
    ACTA RADIOLOGICA, 1990, 31 (05) : 469 - 471
  • [49] ARE HIGH INTENSIFICATION FILM-SCREEN COMBINATIONS SUITABLE FOR THE DETECTION OF FINE INTERSTITIAL LUNG-CHANGES - RESULTS OF A ROC STUDY WITH AN ANTHROPOMORPHIC THORAX PHANTOM
    MULLER, RD
    JOHN, V
    VOSS, M
    BUDDENBROCK, B
    BLENDL, C
    HIRCHE, H
    EWEN, K
    LOHR, E
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 159 (01): : 54 - 59
  • [50] THE USE OF HIGH-SPEED FILM SCREEN COMBINATIONS TO IMPROVE DIAGNOSTIC IMAGE QUALITY
    LEPAGE, JR
    TREFLER, M
    RADIOLOGY, 1983, 147 (01) : 265 - 267