Performance tests for mammographic film-screen combinations: use of absolute techniques

被引:0
|
作者
Bor, Dogan [1 ]
Akdur, Kerime [1 ]
机构
[1] Ankara Univ, Dept Engn Phys, TR-06100 Ankara, Turkey
关键词
X-RAY-SPECTRA; OPTICAL-DENSITY; IMAGE QUALITY;
D O I
10.5152/dir.2013.032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE A performance comparison of film-screen combination used in mammography was conducted using conventional and new techniques. MATERIALS AND METHODS The performance of 30 mammographic film-screen combinations was evaluated by sensitometry, and the total performance was determined using phantom measurements. Quantum detection and light emission efficiency of the screens were also measured as an alternative technique for determining screen speeds. These efficiency measurements provided quantitative results for selecting the optimum beam quality. RESULTS Considering the image quality scores from three observers and the radiation doses obtained from the speed measurements, eight combinations were selected as being optimal. Only three of the mammographic film screen combinations in this group were the recommendations of manufacturers. CONCLUSION The total performance phantom can be effectively used for the qualitative check of image and provide speed information for mammographic film-screen combinations comparable to sensitometric techniques.
引用
收藏
页码:360 / 370
页数:11
相关论文
共 50 条
  • [31] MEASUREMENT OF MODULATION TRANSFER-FUNCTIONS OF FILM-SCREEN COMBINATIONS WITH A LEAD BAR PATTERN
    HOESCHEN, D
    MIRANDE, W
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1984, 140 (05): : 600 - 604
  • [32] A comparison of two mammography film-screen combinations designed for standard-cycle processing
    McParland, BJ
    BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (853): : 73 - 75
  • [33] NOTES ON DETERMINING MODULATION TRANSFER DATA FOR X-RAY FILM-SCREEN COMBINATIONS
    WEISS, JP
    JOURNAL OF APPLIED PHOTOGRAPHIC ENGINEERING, 1978, 4 (02): : 82 - 84
  • [34] Implications of using high contrast mammography X-ray film-screen combinations
    Meeson, S
    Young, KC
    Rust, A
    Wallis, MG
    Cooke, J
    Ramsdale, ML
    BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (885): : 825 - 835
  • [35] NOTES ON DETERMINING MODULATION TRANSFER DATA FOR X-RAY FILM-SCREEN COMBINATIONS.
    Weiss, J.P.
    1978, 4 (02): : 82 - 84
  • [36] An in vitro study comparing two different film-screen combinations in the detection of impacted fish bones
    Abdullah, BJJ
    Kaur, H
    Ng, KH
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (849): : 930 - 933
  • [37] Comparison of direct magnification radiography and mammographic film-screen systems in the detection of subperiosteal, intracortical and endosteal bone resorption
    MullerMiny, H
    Link, T
    BraunAnhalt, I
    Dietl, KH
    Peters, PE
    RADIOLOGE, 1996, 36 (10): : 834 - 839
  • [38] Design and performance features of a new mammographic film/screen system
    Moore, W
    Dickerson, R
    Steklenski, D
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 433 - 444
  • [39] Optimization of tube potential-filter combinations for film-screen mammography - A contrast detail phantom study
    Chida, K
    Zuguchi, M
    Sai, M
    Saito, H
    Yamada, T
    Ishibashi, T
    Ito, D
    Kimoto, N
    Kohzuki, M
    Takahashi, S
    CLINICAL IMAGING, 2005, 29 (04) : 246 - 250
  • [40] Special historical reprint: An assortment of image quality indexes for radiographic film-screen combinations-can they be resolved?
    Myers, Kyle
    Chen, Weijie
    JOURNAL OF MEDICAL IMAGING, 2014, 1 (03)