Performance tests for mammographic film-screen combinations: use of absolute techniques

被引:0
|
作者
Bor, Dogan [1 ]
Akdur, Kerime [1 ]
机构
[1] Ankara Univ, Dept Engn Phys, TR-06100 Ankara, Turkey
关键词
X-RAY-SPECTRA; OPTICAL-DENSITY; IMAGE QUALITY;
D O I
10.5152/dir.2013.032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE A performance comparison of film-screen combination used in mammography was conducted using conventional and new techniques. MATERIALS AND METHODS The performance of 30 mammographic film-screen combinations was evaluated by sensitometry, and the total performance was determined using phantom measurements. Quantum detection and light emission efficiency of the screens were also measured as an alternative technique for determining screen speeds. These efficiency measurements provided quantitative results for selecting the optimum beam quality. RESULTS Considering the image quality scores from three observers and the radiation doses obtained from the speed measurements, eight combinations were selected as being optimal. Only three of the mammographic film screen combinations in this group were the recommendations of manufacturers. CONCLUSION The total performance phantom can be effectively used for the qualitative check of image and provide speed information for mammographic film-screen combinations comparable to sensitometric techniques.
引用
收藏
页码:360 / 370
页数:11
相关论文
共 50 条
  • [1] Storage phosphor and film-screen mammography:: performance with different mammographic techniques
    Kheddache, S
    Thilander-Klang, A
    Lanhede, B
    Månsson, LG
    Bjurstam, N
    Ackerholm, P
    Björneld, L
    EUROPEAN RADIOLOGY, 1999, 9 (04) : 591 - 597
  • [2] Storage phosphor and film-screen mammography: performance with different mammographic techniques
    S. Kheddache
    A. Thilander-Klang
    B. Lanhede
    L. G. Månsson
    N. Bjurstam
    P. Ackerholm
    L. Björneld
    European Radiology, 1999, 9 : 591 - 597
  • [3] QUANTITATIVE-EVALUATION OF FILM AND FILM-SCREEN COMBINATIONS FOR MAMMOGRAPHIC EXAMINATION
    MOORES, BM
    HUFTON, AP
    WRIGLEY, C
    ASBURY, DL
    RAMSDEN, JA
    BRITISH JOURNAL OF RADIOLOGY, 1979, 52 (620): : 626 - 633
  • [4] FILM-SCREEN COMBINATIONS FOR MAMMOGRAPHY
    BAKIR, YYY
    ROEBUCK, EJ
    WHELPTON, D
    WORTHINGTON, BS
    BRITISH JOURNAL OF RADIOLOGY, 1984, 57 (679): : 653 - 653
  • [5] SPEEDS OF FILM-SCREEN COMBINATIONS FOR RADIOGRAPHY
    HOLLOWAY, AF
    CHENG, CN
    PAIX, D
    JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1983, 34 (04): : 331 - 324
  • [6] A Comparison of the effectiveness of Mammographic Film-Screen and Standard Film-Screen in the Detection of Small Bone Fractures
    Sani, Karim Ghazikhanlou
    Jafari, Mahmoodreza
    Rostampoor, Nima
    IRANIAN JOURNAL OF MEDICAL SCIENCES, 2011, 36 (04) : 306 - 310
  • [7] THE PERFORMANCE OF THE IMAGE RECEPTOR WITH SPECIAL REFERENCE TO FILM-SCREEN COMBINATIONS
    MOORES, BM
    BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (645): : 823 - 823
  • [8] THE SENSITIVITY OF FILM-SCREEN COMBINATIONS IN MEDICAL DIAGNOSIS
    HE, GQ
    HOESCHEN, D
    MIRANDE, W
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1982, 137 (06): : 718 - 723
  • [9] EVALUATION OF NEW FILM-SCREEN COMBINATIONS FOR MAMMOGRAPHY
    JENNINGS, RJ
    SIEDBAND, MP
    THOMASON, CL
    ERGUN, DL
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 591 - 591
  • [10] PROBLEM OF USE OF FILM-SCREEN COMBINATIONS CONSISTING ONLY OF FILM AND BACK SCREEN INSTEAD OF FILM WITHOUT SCREENS
    ANGERSTEIN, W
    WOLF, M
    RADIOLOGIA DIAGNOSTICA, 1977, 18 (03) : 417 - 420